{"id":15575,"date":"2026-01-06T13:40:47","date_gmt":"2026-01-06T05:40:47","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15575"},"modified":"2026-01-06T13:40:47","modified_gmt":"2026-01-06T05:40:47","slug":"chuanbo-440v-donglidianwangjueyuanguzhangchazhaoshixunladianfayubengpupaicha-sop","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/chuanbo-440v-donglidianwangjueyuanguzhangchazhaoshixunladianfayubengpupaicha-sop","title":{"rendered":"Ship 440V Power Grid Insulation Fault Finding Practical Training: Pull Method &amp; Pumping SOP"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Ship Power Grid Insulation Fault Finding Practical Training Operation<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; font-weight: bold; letter-spacing: 1px;\">440V\/380V Power System Practical Procedures<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Operational content<\/h2>\n<div style=\"margin-top: 20px; padding: 0 15px;\">\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 15px;\">\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-top: 3px solid #1f365c;\">(1) Analog operation of power grid insulation low alarms<\/div>\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-top: 3px solid #1f365c;\">(2) Correct operation of the pull-power search method<\/div>\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-top: 3px solid #1f365c;\">(3) Testing grid insulation with a hand-operated megohmmeter<\/div>\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-top: 3px solid #1f365c;\">(4) Simulated start-up of emergency generator sets<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">II. Core practical steps<\/h2>\n<div style=\"margin: 20px 0; padding: 0 15px;\">\n<div style=\"background: #eef2f7; border-left: 5px solid #1f365c; padding: 20px; border-radius: 0 8px 8px 0; margin-bottom: 25px;\">\n<p style=\"margin: 0; font-size: 15px;\"><strong>Indicator requirements:<\/strong>The insulation value of the ship's power grid and electrical equipment shall<strong>Not less than 1 M\u03a9<\/strong>. Once the hull insulation resistance has dropped to one volt per volt of supply voltage <strong>100 \u03a9<\/strong> Below this level (e.g. 44 k\u03a9 for a 440 V network), the audible and visual alarm must be triggered.<\/p>\n<\/div>\n<div style=\"display: flex; flex-direction: column; gap: 20px;\">\n<div style=\"display: flex; align-items: flex-start;\"><span style=\"background: #ef9308; color: white; width: 28px; height: 28px; border-radius: 50%; text-align: center; line-height: 28px; margin-right: 15px; flex-shrink: 0; font-weight: bold;\">1<\/span><\/p>\n<div><strong>Initial Disposition:<\/strong>Answer alarms, silencing, and flashing. Observe that the switchboard megohmmeter reads less than 1 M\u03a9.<\/div>\n<\/div>\n<div style=\"display: flex; align-items: flex-start;\"><span style=\"background: #ef9308; color: white; width: 28px; height: 28px; border-radius: 50%; text-align: center; line-height: 28px; margin-right: 15px; flex-shrink: 0; font-weight: bold;\">2<\/span><\/p>\n<div style=\"width: 100%;\"><strong>The essentials of the pull-power search method:<\/strong><\/p>\n<ul style=\"margin: 10px 0; padding-left: 20px; background: #fffaf5; border: 1px solid #ffe8cc; padding: 15px; border-radius: 6px;\">\n<li>Disconnect the power switch one by one and observe the megohmmeter; if the insulation is restored in one of the disconnected paths, the control equipment in that path is faulty.<\/li>\n<li>After confirming the faulty line, cut off the power supply to that line.<\/li>\n<li>Use a hand-operated megohmmeter at the distribution board to measure branch circuit-to-ground conditions one by one.<\/li>\n<li>Isolate the faulty branch, close the remaining switches, and restore power to the non-faulty equipment.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"display: flex; align-items: flex-start;\"><span style=\"background: #ef9308; color: white; width: 28px; height: 28px; border-radius: 50%; text-align: center; line-height: 28px; margin-right: 15px; flex-shrink: 0; font-weight: bold;\">3<\/span><\/p>\n<div><strong>Hand-operated megohmmeter to confirm (120 r\/min):<\/strong><\/p>\n<p style=\"margin: 5px 0;\">\u25cf <strong>Open circuit test:<\/strong>Meter pen open, pointer points to \u201c<strong>\u221e<\/strong>\u201d\u3002<\/p>\n<p style=\"margin: 5px 0;\">\u25cf <strong>Short circuit test:<\/strong>Meter pen shorted (light turn), pointer points to \u201c<strong>0<\/strong>\u201d\u3002<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">III. Power system fault finding (No. 1 sea water pump practical training case)<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\">\n<div style=\"flex: 1; min-width: 300px; border: 2px solid #1f365c; padding: 20px; border-radius: 10px;\">\n<p style=\"margin-top: 0;\"><strong>Fault Setting:<\/strong>50 k\u03a9 resistance between phase B of the first seawater pump and the hull.<\/p>\n<p style=\"color: #d9534f; font-weight: bold;\">Alarm phenomenon:<\/p>\n<p style=\"margin-bottom: 0;\">\u201cAC 440V BUS LOW INSUL.\u201d lamp flashes and buzzer alarms.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 300px; background: #fdf2f2; border: 1px dashed #d9534f; padding: 20px; border-radius: 10px;\">\n<p style=\"margin-top: 0;\"><strong>Failure Analysis:<\/strong>Indicates low power grid insulation. The megohmmeter indicates approximately 0.05 M\u03a9, and phase B of the ground lamp is dimmed.<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 2px solid #ef9308; border-radius: 12px; overflow: hidden;\">\n<div style=\"background: #ef9308; color: white; padding: 15px; font-weight: bold; text-align: center; font-size: 18px;\">Standardized process for power equipment troubleshooting<\/div>\n<div style=\"padding: 25px;\">\n<div style=\"margin-bottom: 15px; display: flex;\"><span style=\"color: #1f365c; font-weight: bold; margin-right: 15px;\">STEP 1<\/span><br \/>\nMute the sound and flash to confirm the alarm. Initial lockout of phase B fault by megohmmeter with ground gas light.<\/div>\n<div style=\"margin-bottom: 15px; display: flex; background: #fff4e6; padding: 10px; border-radius: 4px; border: 1px solid #ef9308;\"><span style=\"color: #ef9308; font-weight: bold; margin-right: 15px;\">Key!<\/span><br \/>\n<strong>Important pumping operations:<\/strong>The standby unit must be started first to replace the currently operating unit, and direct shutdown is strictly prohibited!<\/div>\n<div style=\"margin-bottom: 15px; display: flex;\"><span style=\"color: #1f365c; font-weight: bold; margin-right: 15px;\">STEP 2<\/span><br \/>\nStop each pump and ventilator in turn. Observe the megohmmeter: when the insulation of a motor is restored by stopping it, the faulty machine is locked.<\/div>\n<div style=\"margin-bottom: 0; display: flex;\"><span style=\"color: #1f365c; font-weight: bold; margin-right: 15px;\">STEP 3<\/span><br \/>\nFaulty equipment is shut down and de-energized for targeted treatment to improve insulation (e.g., drying, cleaning).<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electrical and Electronics Officer (ETO) Training Kit | Power Grid Insulation Practices | Revision 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Ship power grid insulation fault finding practical training operation 440V\/380V power system practice procedures I. Operation content (1) simulated operation of power ...<\/p>","protected":false},"author":1,"featured_media":15576,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15575","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15575"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15575\/revisions"}],"predecessor-version":[{"id":15577,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15575\/revisions\/15577"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15576"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15575"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15575"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}