{"id":15588,"date":"2026-01-06T14:35:42","date_gmt":"2026-01-06T06:35:42","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15588"},"modified":"2026-01-06T14:39:00","modified_gmt":"2026-01-06T06:39:00","slug":"chuanbojieandiancaozuoshiwuxiangxuxiaoyanfuxubaohuyuqiehuan-sop-liucheng","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/chuanbojieandiancaozuoshiwuxiangxuxiaoyanfuxubaohuyuqiehuan-sop-liucheng","title":{"rendered":"Ship to shore power operation practice: phase sequence verification, negative sequence protection and switching SOP process"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Mains, emergency and shore power switching practices<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Ship Power Station Management Series: Power Conversion Logic and Shore Power Access Specification<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Logical architecture of the electricity supply relationship<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"text-indent: 2em; margin-bottom: 15px;\">At present, the high-voltage power of large ships can be operated in parallel with the medium-voltage shore power for a short period of time, and the low-voltage power system still in use on ships is introduced here as an example. Through the simulator software, it is necessary to sort out the power supply relationship of main distribution board, emergency distribution board and shore power:<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px; margin-top: 20px;\">\n<div style=\"background: #f8f9fa; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c;\"><strong style=\"color: #1f365c;\">(1) When power is supplied to the main switchboard:<\/strong><br \/>\nThe contact switch closes to supply power to the emergency switchboard. Emergency generator stops and emergency generator main switch is disconnected. Shore power main switch disconnected.<\/div>\n<div style=\"background: #f8f9fa; padding: 20px; border-radius: 8px; border-top: 4px solid #ef9308;\"><strong style=\"color: #ef9308;\">(2) When the emergency generator is powered:<\/strong><br \/>\nContact switch disconnected. Shore power main switch disconnected.<\/div>\n<div style=\"background: #f8f9fa; padding: 20px; border-radius: 8px; border-top: 4px solid #2c3e50;\"><strong style=\"color: #2c3e50;\">(3) When shore power is supplied:<\/strong><br \/>\nThe contact switch closes to supply power to the main and emergency switchboards. Main and emergency generator circuit breakers are disconnected.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">II. Operating instructions for connection to shore power<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Conditions for connection of ships to shore power<\/h3>\n<p style=\"padding-left: 20px; border-left: 4px solid #ef9308;\">The main conditions that should be met when a ship is connected to shore power are: the shore power and ship's electrical<strong>Same electrical system, rated voltage, rated frequency<\/strong>of shore power and ship power<strong>phase sequence is identical<\/strong>The ship's generators should be disconnected from the power grid. It should also be confirmed that all generators on the ship have been disconnected from the grid.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">(ii) Use and monitoring of shore power boxes<\/h3>\n<p>Shore power boxes generally have shore power indicators, switches, fuses, shore power terminals, and phase sequence indicators (or negative sequence relays).<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 20px;\">\n<div style=\"flex: 1; min-width: 300px; background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 8px;\">\n<p><strong style=\"color: #1f365c; display: block; margin-bottom: 10px;\">1. Phase Sequence Detector (Indicator)<\/strong><\/p>\n<p style=\"font-size: 14px;\">Phase sequence determiners are also called phase sequence indicators. The three phases of the circuit are loaded asymmetrically. When a phase connected to capacitor C is set to phase R, the brighter phase is phase S and the darker phase is phase T. When the relationship between the two lights is the same as the sign on the shore power box, it means that the shore power phase sequence is the same as the ship's power phase sequence. When the relationship between the two indicator lights is the same as the sign on the shore power box, it means that the shore power phase sequence is the same as the ship's power phase sequence.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 300px; background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 8px;\">\n<p><strong style=\"color: #1f365c; display: block; margin-bottom: 10px;\">2. Negative Sequence Relay<\/strong><\/p>\n<p style=\"font-size: 14px;\">Negative sequence relay is also called reverse sequence relay. When the shore power phase sequence is correct and the three-phase voltage is symmetrical, the output voltage is 0 and the switch can be closed. When the phase sequence is inconsistent or broken, there is voltage output and the switch cannot be closed. It is used to prevent wrong phase sequence connection or single-phase operation.<\/p>\n<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">(iii) Shore power connection and ship-to-ship power operation procedure (SOP)<\/h3>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 30px; margin-top: 20px;\">\n<div style=\"background: #f0f4f8; padding: 25px; border-radius: 12px; border: 1px solid #d1d9e6;\">\n<h4 style=\"color: #1f365c; margin-top: 0; text-align: center;\">Shore power access steps<\/h4>\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"list-style-type: none;\">\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"margin-bottom: 10px;\">\u2460 Notify the pilothouse and centralized control room; check the shore power voltage and frequency to ensure that it is consistent with the ship's power.<\/li>\n<li style=\"margin-bottom: 10px;\">\u2461 Connect the power cable to the terminal block, close the shore switch, and the phase sequence indicator lights.<\/li>\n<li style=\"margin-bottom: 10px; color: #ef9308; font-weight: bold;\">\u2462 Adjust the phase sequence switch to ensure that the green light is on for the correct phase sequence (as shown in Figure 8-8).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<div style=\"text-align: center; margin: 10px 0;\">\n<div id=\"attachment_15592\" style=\"width: 128px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15592\" class=\"wp-image-15592\" title=\"1caf28063b758e19abb76be52bab8c71\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1caf28063b758e19abb76be52bab8c71.png\" alt=\"Figure 8-8 Shore Power Box Phase Sequence Indicators\" width=\"118\" height=\"107\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1caf28063b758e19abb76be52bab8c71.png 387w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1caf28063b758e19abb76be52bab8c71-300x272.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1caf28063b758e19abb76be52bab8c71-13x12.png 13w\" sizes=\"(max-width: 118px) 100vw, 118px\" \/><p id=\"caption-attachment-15592\" class=\"wp-caption-text\"><strong>Figure 8-8 Shore Power Box Phase Sequence Indicators<\/strong><\/p><\/div>\n<\/div>\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"list-style-type: none;\">\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"margin-bottom: 10px;\">\u2463 Press the shore power box closing button and the closing lamp lights up.<\/li>\n<li style=\"margin-bottom: 10px;\">\u2464 Disconnect the load, disconnect the main generator switch, and close the main switchboard shore power switch in turn (as shown in Figure 8-9).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<div style=\"text-align: center; margin: 10px 0;\">\n<div id=\"attachment_15594\" style=\"width: 123px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15594\" class=\"wp-image-15594\" title=\"8d4b31384ac144ce4ed70daf96079885-1\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8d4b31384ac144ce4ed70daf96079885-1.png\" alt=\"Figure 8-9 Shore Power Switch\" width=\"113\" height=\"136\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8d4b31384ac144ce4ed70daf96079885-1.png 379w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8d4b31384ac144ce4ed70daf96079885-1-249x300.png 249w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8d4b31384ac144ce4ed70daf96079885-1-10x12.png 10w\" sizes=\"(max-width: 113px) 100vw, 113px\" \/><p id=\"caption-attachment-15594\" class=\"wp-caption-text\"><strong>Figure 8-9 Shore Power Switch<\/strong><\/p><\/div>\n<\/div>\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"margin-bottom: 0;\">(vi) Discontinue operation of the generator set.<\/li>\n<\/ul>\n<\/div>\n<div style=\"background: #fef9f3; padding: 25px; border-radius: 12px; border: 1px solid #ffe8cc;\">\n<h4 style=\"color: #ef9308; margin-top: 0; text-align: center;\">Shore power to ship power operation procedure<\/h4>\n<ul style=\"font-size: 14px; padding-left: 15px;\">\n<li style=\"margin-bottom: 10px;\">\u2460 Notify the relevant compartments; switch the control mode to manual and start the main generator set in readiness.<\/li>\n<li style=\"margin-bottom: 10px;\">\u2461 Disconnect the shore power switch at the main switchboard.<\/li>\n<li style=\"margin-bottom: 10px; font-weight: bold;\">\u2462 Immediately close the main switch of the generator set to restore the power supply and start the critical load according to the procedure.<\/li>\n<li style=\"margin-bottom: 10px;\">\u2463 Press the break button on the shore power box.<\/li>\n<li style=\"margin-bottom: 0;\">\u2464 Disconnect the shore switch and remove the shore power power cable.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 40px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">C. Safety Checklist for Connecting to Shore Power<\/h2>\n<div style=\"background: #fff; border: 2px solid #1f365c; padding: 25px; border-radius: 8px; margin-top: 20px;\">\n<p style=\"margin-bottom: 10px;\">(1) When connecting to shore power, the shore power and ship power of the<strong>Current type, rated frequency, rated voltage<\/strong>There must be consistency.<\/p>\n<p style=\"margin-bottom: 10px;\">(2) When the shore power is a three-phase, four-wire system, the shore power shall be<strong>neutral conductor<\/strong>Connect to the terminal block on the shore power box that connects to the hull. Shore power can only be switched on when the hull is connected to the shore power neutral.<\/p>\n<p style=\"margin-bottom: 10px;\">(3) Close the shore power box switch, and only when the shore power phase sequence is the same as the ship's power phase sequence can you go to the main switchboard to perform the transfer operation.<\/p>\n<p style=\"margin-bottom: 0; color: #b30000; font-weight: bold;\">(4) Risk of prohibited parallel operation: When the ship is connected to shore power, the ship's generator is strictly prohibited from being switched on to supply power. Only after the shore power is removed can the generator be turned on to supply power, and it is impossible for both to be turned on at the same time (electrical interlocking protection).<\/p>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 60px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Ship's Electrical and Electronic Officer (ETO) Practical Training Kit | 2026 Revision | Full Text Version<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Switching Practices of Main Power, Emergency Power and Shore Power Ship Power Station Management Series: Power Conversion Logic and Shore Power Access Specification I. Logical Architecture of Power Supply Relationships Currently, ...<\/p>","protected":false},"author":1,"featured_media":15589,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15588","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15588"}],"version-history":[{"count":3,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15588\/revisions"}],"predecessor-version":[{"id":15596,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15588\/revisions\/15596"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15589"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15588"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15588"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}