{"id":15604,"date":"2026-01-06T16:08:17","date_gmt":"2026-01-06T08:08:17","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15604"},"modified":"2026-01-06T16:08:17","modified_gmt":"2026-01-06T08:08:17","slug":"ups-bujianduandianyuanxitongshezhicaozuoyuweihushiwuzhinan","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/ups-bujianduandianyuanxitongshezhicaozuoyuweihushiwuzhinan","title":{"rendered":"UPS Uninterruptible Power Supply Systems: A Practical Guide to Setup, Operation and Maintenance"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">UPS Uninterruptible Power Supply Systems: A Practical Guide to Setup, Operation and Maintenance<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Manual for Power Supply Assurance of Critical Control Systems on Ships<\/div>\n<\/div>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Section I. UPS Overview<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"text-indent: 2em; margin-bottom: 15px;\">UPS is the English abbreviation for Uninterruptible Power System. When power quality problems occur in the power grid, such as surge, high voltage spike, transient overvoltage, voltage sag, line noise, frequency shift, continuous low voltage, power supply interruption, the UPS will ensure the output of stable, pure, uninterrupted sinusoidal AC voltage so that the microcomputer system or the corresponding control system can continue to maintain normal operation.<\/p>\n<div style=\"background: #f0f4f8; border-radius: 8px; padding: 25px; margin: 20px 0; border-left: 5px solid #1f365c;\">\n<p style=\"margin-top: 0;\"><strong>Core conversion logic:<\/strong>UPS in the usual sense of the input is 220V AC, the output is also 220V AC, but through the middle of the power electronic conversion and battery link. In the 220 V normal power supply, through the rectifier to keep the battery charged, while the inverter can output 220 V AC; in the power supply 220 V power failure, the battery through the discharge and inverter, can continue to maintain a period of 220 V output to achieve uninterrupted power supply.<\/p>\n<p style=\"margin-bottom: 0; color: #d9534f; font-weight: bold;\">Alarm Mechanism: Audible and visual alarm when battery energy is about to be exhausted. When overloaded (150% load), jumps to bypass state and returns automatically when load is normal.<\/p>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">UPS Three major classifications<\/h3>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px; margin-top: 15px;\">\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 6px;\"><strong>1. Backup UPS:<\/strong>Filters output and charges only during normal times. Switches to battery\/inverter power after power interruption.<\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 6px;\"><strong>2. On-line UPS:<\/strong>The inverter always works without switching time. Equipped with voltage stabilization and prevention of electric wave interference.<\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 6px;\"><strong>3. Double conversion on-line UPS:<\/strong>AC\u2192DC\u2192AC conversion to provide pure and stable voltage. The battery is connected to the DC bus.<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">Core Component Composition<\/h3>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 15px;\">\n<div style=\"flex: 1; min-width: 240px; background: #fafafa; padding: 15px; border-radius: 6px;\"><strong style=\"color: #1f365c;\">1. Rectifier (AC\u2192DC)<\/strong><br \/>\nFor use with loads or inverters and as a charger to power batteries.<\/div>\n<div style=\"flex: 1; min-width: 240px; background: #fafafa; padding: 15px; border-radius: 6px;\"><strong style=\"color: #1f365c;\">2. Storage batteries (energy storage)<\/strong><br \/>\nCapacity determines the time to maintain discharge. Converts chemical and electrical energy to each other.<\/div>\n<div style=\"flex: 1; min-width: 240px; background: #fafafa; padding: 15px; border-radius: 6px;\"><strong style=\"color: #1f365c;\">3. Inverter (DC\u2192AC)<\/strong><br \/>\nIt consists of an inverter bridge, control logic and filter circuit.<\/div>\n<div style=\"flex: 1; min-width: 240px; background: #fafafa; padding: 15px; border-radius: 6px;\"><strong style=\"color: #1f365c;\">4. Static switching (non-contact changeover)<\/strong><br \/>\nIt consists of SCRs and is divided into conversion type (dual power supply switching) and parallel type.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Section 2: Use and Maintenance of UPS<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"background: #fdf6ec; border: 1px solid #faecd8; padding: 25px; border-radius: 12px; margin-bottom: 40px;\">\n<h3 style=\"color: #1f365c; margin-top: 0;\">I. UPS startup and shutdown sequence<\/h3>\n<p><strong>1. First power-up:<\/strong>Storage battery switch \u2192 automatic bypass switch \u2192 output switch \u201cON\u201d. Press the \u201cON\u201d button to start, wait until the \u201cBypass\u201d lamp goes out and turn to inverter power supply. After 10min of no load, turn on the load from small to large.<\/p>\n<p><strong>2. Daily start-up:<\/strong>Press the \u201cON\u201d button and turn on the load switch after about 20 min of stabilization (the manual maintenance switch should be \u201cOFF\u201d).<\/p>\n<p><strong>3. Shutdown:<\/strong>Turn off the load first, let the UPS run no-load for 10min to remove heat, and then press the \u201cOff\u201d button on the panel.<\/p>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">Precautions for the use of UPS<\/h3>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin-top: 15px;\">\n<ul style=\"padding-left: 20px;\">\n<li>Environment: Avoid dust and grease intrusion.<\/li>\n<li>Sequence: power on (power supply \u2192 UPS \u2192 load); power off (load \u2192 UPS \u2192 power supply).<\/li>\n<li>Contacts: Ensure that air switches, gate knives, sockets, etc. are making good contact and are not firing.<\/li>\n<\/ul>\n<ul style=\"padding-left: 20px;\">\n<li style=\"color: #d9534f;\"><strong>Load limitation: It is not allowed to connect inductive loads (such as electric drill), and overloading is prohibited.<\/strong><\/li>\n<li>Heat dissipation: Clean air inlet holes every 2-3 months.<\/li>\n<\/ul>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">III. Routine maintenance and overhaul (battery focus)<\/h3>\n<p style=\"text-indent: 2em;\">The main work lies in dust control and battery maintenance. Quarterly thorough cleaning of the mainframe is required. Maintenance still requires in-depth analysis as the UPS fault self-test may have false alarms.<\/p>\n<div style=\"border: 2px solid #1f365c; border-radius: 12px; overflow: hidden; margin-top: 20px;\">\n<div style=\"background: #1f365c; color: #fff; padding: 10px 20px; font-weight: bold;\">Battery Maintenance Manual<\/div>\n<div style=\"padding: 20px; background: #fff;\">\n<p>\u25cf <strong>Discharge Protocol:<\/strong>Discharge the battery at least once a year under float charging mode and equalize the charge before discharging. Attend to and dispose of outdated batteries.<\/p>\n<p>\u25cf <strong>Labeled batteries:<\/strong>There are 8 labeled cells in each group, and regular measurements are recorded as a reference for the whole group.<\/p>\n<p>\u25cf <strong>Daily inspections:<\/strong>Voltage, temperature, corrosion of connections, shell deformation and leakage, escape of acid mist from safety valves.<\/p>\n<p>\u25cf <strong>Troubleshooting:<\/strong>Reverse polarity, high pressure drop, high differential pressure or leaking batteries are found to need to be repaired or replaced in a timely manner.<strong>Mixing batteries of different capacities\/performance\/manufacturers is prohibited.<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 40px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Section III UPS Setup and Maintenance Example<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">I. UPS operation mode status check<\/h3>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px; margin-top: 15px;\">\n<div style=\"background: #eef2f7; padding: 15px; border-radius: 6px;\"><strong>1. Normal mode of operation:<\/strong>AC\u2192DC charging and eliminating pollution (surges, noise, etc.) and providing voltage regulation.<\/div>\n<div style=\"background: #eef2f7; padding: 15px; border-radius: 6px;\"><strong>2. Battery operating mode:<\/strong>When the utility power is abnormal, DC\u2192AC conversion provides power until the power runs out or returns to normal.<\/div>\n<div style=\"background: #fff5f5; padding: 15px; border-radius: 6px; border: 1px solid #feb2b2;\"><strong>3. Bypass mode of operation:<\/strong>Directly connected to the mains in case of overload or fault. Adopt phase-locked synchronization technology to ensure phase consistency.<\/div>\n<\/div>\n<div style=\"margin-top: 35px; background: #fff; border: 1px solid #ddd; padding: 25px; border-radius: 12px; box-shadow: 0 4px 12px rgba(0,0,0,0.05);\">\n<h4 style=\"text-align: center; color: #1f365c; margin-top: 0;\">APC UPS Panel Legend Explanation<\/h4>\n<div id=\"attachment_15605\" style=\"width: 370px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15605\" class=\"wp-image-15605\" title=\"420a6ffe175bada52bc1d9aa5e4bdfab\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/420a6ffe175bada52bc1d9aa5e4bdfab.png\" alt=\"Figure 10-1 APCUPS Panel\" width=\"360\" height=\"378\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/420a6ffe175bada52bc1d9aa5e4bdfab.png 747w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/420a6ffe175bada52bc1d9aa5e4bdfab-285x300.png 285w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/420a6ffe175bada52bc1d9aa5e4bdfab-11x12.png 11w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/420a6ffe175bada52bc1d9aa5e4bdfab-600x631.png 600w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><p id=\"caption-attachment-15605\" class=\"wp-caption-text\">Figure 10-1 APCUPS Panel<\/p><\/div>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 10px; font-size: 13px; color: #555; margin-top: 20px;\">\n<div><strong>A: Load<\/strong> Load Load Display<\/div>\n<div><strong>B: On-Line<\/strong> Online Pure Power Status<\/div>\n<div><strong>C: On-Battery<\/strong> Battery powered (with alarm)<\/div>\n<div><strong>D: Bypass<\/strong> Bypass Mode Indication<\/div>\n<div><strong>E: Overload<\/strong> Overload warning (with alarm)<\/div>\n<div><strong>F: Fault<\/strong> Internal fault indication<\/div>\n<div><strong>G: Replace Battery<\/strong> Battery Replacement Alarm<\/div>\n<div><strong>H: Battery Charge<\/strong> Charging ratio \/ mains voltage<\/div>\n<div><strong>I: Off<\/strong> Shutdown button (recessed to prevent accidental contact)<\/div>\n<div><strong>J: On\/Test<\/strong> Startup\/Self-test\/Voltage Display<\/div>\n<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">UPS operation mode switching test practice<\/h3>\n<div style=\"background: #1f365c; color: white; padding: 20px; border-radius: 8px; margin-top: 15px;\">\n<p style=\"margin-top: 0;\"><strong>Test Process SOP:<\/strong><\/p>\n<ol style=\"padding-left: 20px;\">\n<li>Shut down all critical loads.<\/li>\n<li>Disconnect the boat power input switch (analog loss of power).<\/li>\n<li>Start the UPS with the battery, switch to<strong>Battery powered mode<\/strong>Check the inverter voltage and light display.<\/li>\n<li>Close the boat power input switch and verify that the UPS can automatically jump back to the<strong>normal mode<\/strong>(ship's electric power supply).<\/li>\n<li>If the jump is abnormal, disconnect the mains switch again after a few seconds to observe the inverter status.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electrical and Electronics Officer (ETO) Technical Training Manual | UPS Maintenance and Management | Revision 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UPS Uninterruptible Power Supply System: A Practical Guide to Setup, Operation and Maintenance Power Supply Assurance for Ship's Critical Control Systems Manual Section 1 UPS Overview UPS ...<\/p>","protected":false},"author":1,"featured_media":15606,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15604","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15604"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15604\/revisions"}],"predecessor-version":[{"id":15607,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15604\/revisions\/15607"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15606"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15604"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15604"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}