{"id":15648,"date":"2026-01-06T17:36:13","date_gmt":"2026-01-06T09:36:13","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15648"},"modified":"2026-01-06T17:36:13","modified_gmt":"2026-01-06T09:36:13","slug":"dianganqishibieyuceliangzhinangankangjisuangongshiceliangfangfayufuhaowaixing","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/dianganqishibieyuceliangzhinangankangjisuangongshiceliangfangfayufuhaowaixing","title":{"rendered":"Inductor Identification and Measurement Guide: Reactance Calculation Formulas, Measurement Methods and Symbol Shapes"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Basic electrician practice: identification and measurement of inductance<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Fundamental Skills Training in Marine Electronics and Electrical Systems<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Basic concepts of inductance<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"text-indent: 2em; margin-bottom: 15px;\">Inductors, also known as inductive components, belong to energy storage components, which can convert electrical energy into magnetic energy and store it. Inductors mainly play the role of frequency division, filtering and resonance in circuits, and are mainly classified into the following categories according to their structure and use:<\/p>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin-bottom: 25px;\">\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-left: 4px solid #1f365c;\"><strong>\u25cf Ordinary inductors (fixed inductors):<\/strong>Includes color ring inductors and color coded inductors.<\/div>\n<div style=\"background: #f8f9fa; padding: 15px; border-radius: 6px; border-left: 4px solid #ef9308;\"><strong>\u25cf Inductors with magnetic cores:<\/strong>Includes magnetic bar inductors and magnetic ring inductors.<\/div>\n<\/div>\n<div style=\"text-align: center; margin-top: 20px; background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px;\">\n<div id=\"attachment_15649\" style=\"width: 717px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15649\" class=\"wp-image-15649\" title=\"Figure 12-5 Symbols and Shapes of Inductors\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030.png\" alt=\"Figure 12-5 Symbols and Shapes of Inductors\" width=\"707\" height=\"574\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030.png 1074w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030-300x244.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030-1024x831.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030-768x624.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030-15x12.png 15w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/2fc90311a6a32282e119ab5d5d088030-600x487.png 600w\" sizes=\"(max-width: 707px) 100vw, 707px\" \/><p id=\"caption-attachment-15649\" class=\"wp-caption-text\">Figure 12-5 Symbols and Shapes of Inductors<\/p><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 40px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">II. Inductance Measurement Methods<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"background: #f0f4f8; padding: 25px; border-radius: 12px; border: 1px solid #d1d9e6;\">\n<p><strong>(1) Measure the inductance coil on and off:<\/strong>Use a multimeter resistance block to directly test the coil for an open circuit.<\/p>\n<p><strong>(2) Dynamic feedback of measured inductance:<\/strong>When using a pointer multimeter, the initial judgment is made by observing the micro-movement feedback of the pointer through the momentary on-off.<\/p>\n<p><strong>(3) The inductance method calculates the inductance value:<\/strong><\/p>\n<p style=\"padding-left: 20px; border-left: 4px solid #ef9308; background: #fff; padding: 15px; margin: 15px 0;\">Connect a resistor in series with an alternating current, measure the voltage across the inductor and the current through it, and calculate the inductive reactance XL from Ohm's law. then calculate the value of the inductance according to the following formula:<\/p>\n<div style=\"text-align: center; background: #fff; padding: 20px; border-radius: 8px; margin: 20px 0; border: 1px solid #eee; font-size: 1.2em;\">XL=wL=2\u03c0fL<\/div>\n<div style=\"background: #fff; padding: 15px; border-radius: 6px; font-size: 14px;\">\n<p style=\"margin-bottom: 5px;\"><strong>Style:<\/strong><\/p>\n<ul style=\"list-style: none; padding-left: 10px;\">\n<li>X, - reactance in ohms (\u03a9).;\n<p>w - the angular frequency of the power supply in radians\/second;<\/p>\n<p>f - frequency in hertz (Hz).;<\/p>\n<p>L-- Coil inductance, unit is Henry (H).<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"text-align: center; margin-top: 25px;\"><\/div>\n<\/div>\n<\/section>\n<div style=\"margin: 40px 15px 0; background: #1f365c; color: white; padding: 20px; border-radius: 8px;\"><strong style=\"color: #ef9308;\">\ud83d\udee1\ufe0f Core Operating Points:<\/strong><\/p>\n<p style=\"margin: 5px 0 0 0; font-size: 14px;\">When measuring coils with high inductance values (e.g., large transformer windings), high voltage may be generated at the moment of disconnecting the measurement due to the inductance's reverse electromotive force characteristic. Be sure to pay attention to meter range protection and operational safety.<\/p>\n<\/div>\n<footer style=\"text-align: center; margin-top: 60px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Fundamental Skills Training in Marine Electronics and Electrical Systems | Basic Measurement Techniques | Revised Edition 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Basic electrician practice: the identification and measurement of inductance Marine Electronics and Electrical Basic Skills Training I. Basic Concept of Inductance Inductors, also known as inductive components, belong to the energy storage...<\/p>","protected":false},"author":1,"featured_media":15650,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15648","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15648"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15648\/revisions"}],"predecessor-version":[{"id":15651,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15648\/revisions\/15651"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15650"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15648"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15648"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}