{"id":15705,"date":"2026-01-06T19:32:01","date_gmt":"2026-01-06T11:32:01","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15705"},"modified":"2026-01-06T19:32:01","modified_gmt":"2026-01-06T11:32:01","slug":"qianxingdianliubiaodeshiyongshiwu","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/qianxingdianliubiaodeshiyongshiwu","title":{"rendered":"Practical Application of Clamp-On Ammeters"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Practical Application of Clamp-On Ammeters<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Instrumentation Fundamentals \u00b7 Specification for Online Measurement of Alternating Current<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Basic Concepts of Clamp-On Ammeters<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: flex-start; margin-bottom: 30px;\">\n<div style=\"flex: 1; min-width: 300px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">1. Purpose<\/h3>\n<p style=\"text-indent: 2em;\">Clamp-on ammeters, as shown in Figure 13-18, can measure alternating current without interrupting the circuit. They are commonly used to measure the starting and operating currents of three-phase asynchronous motors, check whether the three-phase currents are balanced, and determine if the motor is operating under overload conditions. Most modern clamp-on ammeters are integrated into multimeter units, capable of measuring not only alternating current but also other electrical quantities.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 300px; text-align: center;\">\n<div id=\"attachment_15706\" style=\"width: 64px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15706\" class=\"wp-image-15706\" title=\"Figure 13-18 Clamp-On Ammeter\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/a4fcf6b4f877a5a0388b3951763981ee.png\" alt=\"Figure 13-18 Clamp-On Ammeter\" width=\"54\" height=\"157\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/a4fcf6b4f877a5a0388b3951763981ee.png 148w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/a4fcf6b4f877a5a0388b3951763981ee-103x300.png 103w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/a4fcf6b4f877a5a0388b3951763981ee-4x12.png 4w\" sizes=\"(max-width: 54px) 100vw, 54px\" \/><p id=\"caption-attachment-15706\" class=\"wp-caption-text\">Figure 13-18 Clamp-On Ammeter<\/p><\/div>\n<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">2. Composition<\/h3>\n<p>A clamp-on ammeter is essentially composed of an iron-core, openable current transformer and a magnetoelectric ammeter. The range selector switch and shunt resistor are used to change the measurement range.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">3. Measurement Principle<\/h3>\n<div style=\"background: #f9f9f9; padding: 25px; border-radius: 8px; border-left: 5px solid #1f365c;\">\n<p>The principle of measuring current with a clamp-on ammeter is shown in Figure 13-19. When current I_p flows through the conductor being measured, a current I_c is induced in the secondary winding. According to the transformer principle, I_c = I_p \/ N, where N represents the number of turns in the secondary winding, typically ranging from several dozen to several hundred turns or more. This transforms the high current in the primary winding into a low current in the secondary winding. After rectification by a diode to convert alternating current to direct current flowing through the meter, the magnitude of the primary current can be detected.<\/p>\n<div style=\"text-align: center; margin-top: 20px;\">\n<div id=\"attachment_15707\" style=\"width: 282px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15707\" class=\"wp-image-15707\" title=\"Figure 13-19: Schematic Diagram of a Clamp-On Ammeter\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d4bac7e4c1218e7b56161471cd1dcec7.png\" alt=\"Figure 13-19: Schematic Diagram of a Clamp-On Ammeter\" width=\"272\" height=\"137\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d4bac7e4c1218e7b56161471cd1dcec7.png 658w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d4bac7e4c1218e7b56161471cd1dcec7-300x151.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d4bac7e4c1218e7b56161471cd1dcec7-18x9.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d4bac7e4c1218e7b56161471cd1dcec7-600x303.png 600w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><p id=\"caption-attachment-15707\" class=\"wp-caption-text\">Figure 13-19: Schematic Diagram of a Clamp-On Ammeter<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">II. Usage Methods and Precautions for Clamp-On Ammeters<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 25px; border-radius: 12px; margin-bottom: 35px;\">\n<h3 style=\"color: #1f365c; margin-top: 0;\">1. How to Use<\/h3>\n<ul style=\"list-style-type: none; padding-left: 0;\">\n<li style=\"margin-bottom: 12px;\"><strong>(1) Zero adjustment:<\/strong>Before use, check whether the pointer is positioned at zero. If not, adjust the mechanical zero adjuster on the dial cover to perform zero calibration.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>(2) Select Range:<\/strong>Select the appropriate range based on the magnitude of the current being measured. When the magnitude of the current is unknown, start with the highest range and then adjust the range based on the measurement results.<\/li>\n<li style=\"margin-bottom: 12px;\"><strong>(3) Place the wire:<\/strong>Place the current-carrying conductor to be tested at the center of the iron core to measure the current value.<\/li>\n<li style=\"margin-bottom: 12px; background: #fff8e6; padding: 10px; border-radius: 4px;\"><strong>(4) Techniques for Measuring Small Currents:<\/strong>If the pointer deflection remains small when using the minimum range, you may wrap the wire several times for measurement when conditions permit. In this case:<br \/>\n<span style=\"color: #c0392b; font-weight: bold; padding-left: 20px;\">Actual current measurement = reading \/ number of turns.<\/span><\/li>\n<li style=\"margin-bottom: 0;\"><strong>(5) Storage Guidelines:<\/strong>After measurement, set the selector switch to the maximum range position (current range) or the \u201cOFF\u201d position.<\/li>\n<\/ul>\n<\/div>\n<div style=\"background: #fdf2f2; border: 2px solid #c0392b; padding: 25px; border-radius: 12px;\">\n<h3 style=\"color: #c0392b; margin-top: 0;\">2. Precautions<\/h3>\n<ul style=\"list-style-type: none; padding-left: 0;\">\n<li style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"><span style=\"color: #c0392b; margin-right: 10px;\">\ud83d\udd34<\/span><br \/>\n<strong>(1) Jaw cleaning:<\/strong>Keep the jaws clean and tightly closed; squeeze them firmly by hand if necessary.<\/li>\n<li style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"><span style=\"color: #c0392b; margin-right: 10px;\">\ud83d\udd34<\/span><br \/>\n<strong>(2) Zero Adjustment and Positioning:<\/strong>Before use, ensure the meter is zeroed. Place the meter flat and away from strong magnetic fields. Position the current-carrying conductor vertically at the center of the iron core.<\/li>\n<li style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"><span style=\"color: #c0392b; margin-right: 10px;\">\ud83d\udd34<\/span><br \/>\n<strong>(3) Range Principle:<\/strong>When the magnitude of the current being measured is unknown, start with the maximum range measurement.<\/li>\n<li style=\"margin-bottom: 0; display: flex; align-items: flex-start;\"><span style=\"color: #c0392b; margin-right: 10px;\">\ud83d\udd34<\/span><br \/>\n<strong>(4) Transformation Prohibition:<\/strong>Do not change the range during measurement.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 60px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Fundamental Skills Training in Marine Electronics and Electrical Systems | Basic Measurement Techniques | Revised Edition 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Practical Application of Clamp Meters Instrument Fundamentals \u00b7 AC Current Online Measurement Specifications I. Basic Concepts of Clamp Meters 1. Purpose Clamp meters, such as...<\/p>","protected":false},"author":1,"featured_media":15708,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15705","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15705"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15705\/revisions"}],"predecessor-version":[{"id":15709,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15705\/revisions\/15709"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15708"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15705"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15705"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}