{"id":15735,"date":"2026-01-06T21:30:32","date_gmt":"2026-01-06T13:30:32","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15735"},"modified":"2026-01-06T21:30:32","modified_gmt":"2026-01-06T13:30:32","slug":"bianyaqideshiyongweihucongjichuyuanlidaojixingpanding","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/bianyaqideshiyongweihucongjichuyuanlidaojixingpanding","title":{"rendered":"Transformer Operation and Maintenance: From Fundamental Principles to Polarity Determination"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Transformer Operation and Maintenance: From Fundamental Principles to Polarity Determination<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Ship's Electrical and Electronics Officer (ETO) Technical Training Materials<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px; background: #f0f4f8; padding: 25px; border-radius: 10px; border-left: 10px solid #1f365c;\">\n<p style=\"text-indent: 2em; margin: 0; font-weight: 500;\">A transformer is a stationary electrical device that belongs to a type of motor that rotates at zero speed. Power transformer in the system work, can be the primary side of the power by its electromagnetic energy conversion transmission to the secondary side, while according to the transmission and distribution of the needs of the voltage will be raised or lowered. Therefore, it is in the production of electric energy and distribution of the use of the whole process of the role is very important. In the whole power system, the capacity of the transformer is usually more than 3 times the generator capacity.<\/p>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">II. Nameplate content of the transformer<\/h2>\n<div style=\"margin-top: 30px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Transformer type analysis<\/h3>\n<p style=\"text-indent: 2em;\">Transformer model is divided into two parts, the first part consists of Chinese pinyin letters, representing the category, structural characteristics and use of the transformer, and the second part consists of numbers, indicating the capacity of the product (kV-A) and high-voltage winding voltage (kV) level.<\/p>\n<div style=\"background: #fff; border: 1px solid #ddd; border-radius: 12px; padding: 25px; margin: 20px 0; box-shadow: 0 4px 15px rgba(0,0,0,0.05);\">\n<p style=\"font-weight: bold; color: #1f365c; border-left: 4px solid #ef9308; padding-left: 10px; margin-bottom: 15px;\">Detailed explanation of the meaning of the letters of the Hanyu Pinyin alphabet:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; font-size: 14px;\">\n<tbody>\n<tr style=\"background: #f9f9f9; border-bottom: 1px solid #eee;\">\n<td style=\"padding: 12px; width: 140px; font-weight: bold; color: #1f365c;\">Part 1 (phases)<\/td>\n<td style=\"padding: 12px;\"><strong>D<\/strong>--Single-phase;<strong>S<\/strong>-Three phases.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 12px; font-weight: bold; color: #1f365c;\">Part 2 (Cooling)<\/td>\n<td style=\"padding: 12px;\"><strong>J<\/strong>--Oil immersion self-cooling;<strong>F<\/strong>--Oil immersion air-cooled;<strong>FP<\/strong>--Forced oil circulation air-cooled;<strong>SP<\/strong>--Forced oil circulation water cooling.<\/td>\n<\/tr>\n<tr style=\"background: #f9f9f9; border-bottom: 1px solid #eee;\">\n<td style=\"padding: 12px; font-weight: bold; color: #1f365c;\">Part 3 (Voltage)<\/td>\n<td style=\"padding: 12px;\"><strong>S<\/strong>--Three levels of voltage, no S indicates two levels of voltage.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; font-weight: bold; color: #1f365c;\">Other code meanings<\/td>\n<td style=\"padding: 12px; line-height: 2;\"><strong>L<\/strong>--Aluminum coils or lightning protection;<br \/>\n<strong>0<\/strong>--autocoupling (buck autocoupling in the first place, boost autocoupling in the last place).;<br \/>\n<strong>Z<\/strong>--On-load voltage regulation;<br \/>\n<strong>TH<\/strong>-- Hot and humid zone (protection type code).; <strong>TA<\/strong>--Dry heat tape (protection type code).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 20px; margin-top: 30px;\">\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\">\n<h4 style=\"color: #1f365c; margin-top: 0; border-bottom: 1px solid #eee; padding-bottom: 10px;\">(ii) Rated capacity (S)<sub>N<\/sub>)<\/h4>\n<p style=\"font-size: 14px; text-indent: 2em;\">The rated capacity is the guaranteed value of the apparent power output of the transformer specified by the manufacturer in the rated operating condition (i.e., in the rated voltage, rated frequency, rated operating conditions), and is expressed in terms of S<sub>N<\/sub>Indication. Rated capacity usually refers to the capacity of the high-voltage windings; when the transformer capacity is changed due to the cooling method, the rated capacity refers to its maximum capacity.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\">\n<h4 style=\"color: #1f365c; margin-top: 0; border-bottom: 1px solid #eee; padding-bottom: 10px;\">(iii) Rated current (I)<sub>1<\/sub>I<sub>2<\/sub>)<\/h4>\n<p style=\"font-size: 14px; text-indent: 2em;\">Transformer one or two rated current is the rated voltage and rated ambient temperature so that the transformer parts do not exceed the temperature of the first and second winding long-term allowable through the line current, unit A.<\/p>\n<\/div>\n<\/div>\n<div style=\"margin-top: 30px; background: #fff; border: 1px solid #eee; padding: 25px; border-radius: 8px; border-top: 4px solid #1f365c; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\">\n<h4 style=\"color: #1f365c; margin-top: 0; border-bottom: 1px solid #eee; padding-bottom: 10px;\">(iv) Rated voltage (U)<sub>N<\/sub>)<\/h4>\n<p style=\"font-size: 14px; text-indent: 2em;\">The rated voltage of a transformer is the rated voltage of each winding, which is the rated applied or no-load generated voltage. The primary rated voltage U<sub>1n<\/sub>is the rated voltage value received at the end point of the primary winding of the transformer; the secondary rated voltage U<sub>2n<\/sub>It is the voltage (in V or kV) of the secondary winding when the voltage connected to the primary winding is rated and the transformer is unloaded. The rated voltage of a three-phase transformer refers to the line voltage.<\/p>\n<p style=\"font-size: 14px; text-indent: 2em; background: #fdf6ec; padding: 15px; border-radius: 4px; border-left: 4px solid #ef9308;\"><strong>Expert Interpretation:<\/strong>In general, the appropriate tap is drawn on the high-voltage winding, the high-voltage winding or its individual regulating winding is often set on the outermost side, and it is convenient to draw out the tap; the current on the high-voltage side is small, the current-carrying part of the lead and the tap changer is small in cross-section, and the tap changer contact contacts are easier to manufacture.<\/p>\n<\/div>\n<div style=\"margin-top: 30px; background: #f9f9f9; padding: 25px; border-radius: 12px; border: 1px solid #ddd;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">(v) Connection group analysis<\/h4>\n<p style=\"font-size: 14px; text-indent: 2em;\">The connection group indicates the connection mode of each phase winding of the transformer and the phase relationship between the primary and secondary line voltages. Symbol order from left to right each represents one, the secondary winding connection mode, the number indicates the two winding connection group number. The general high-voltage transformer is basically <strong>Yn, Y, d11<\/strong> Wiring.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 15px;\">\n<div style=\"flex: 1; background: #fff; padding: 15px; border-radius: 6px; border: 1px solid #eee;\"><strong>\u201cYn\u201d<\/strong> Indicates that the primary side is wired as a star with a neutral;<strong>Y<\/strong> indicates a star shape.<strong>n<\/strong> Indicates with neutral.<\/div>\n<div style=\"flex: 1; background: #fff; padding: 15px; border-radius: 6px; border: 1px solid #eee;\"><strong>\u201cd\u201d<\/strong> Indicates triangular wiring on the secondary side.<\/div>\n<div style=\"flex: 1; background: #fff; padding: 15px; border-radius: 6px; border: 1px solid #eee;\"><strong>\u201c11\u201d<\/strong> denotes the line voltage on the secondary side of the transformer U<sub>ab<\/sub> Lagging primary side line voltage U<sub>AB<\/sub> 330\u00b0 (or 30\u00b0 ahead).<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">1. Definition of the homonymous and heteronymous ends of a transformer<\/h2>\n<div style=\"margin-top: 25px; padding: 0 10px;\">\n<p style=\"text-indent: 2em;\">As shown in Figure 15-1, this small black dot labeled on the transformer coil indicates a homonymous terminal. Homonymous end, is the mutual inductance coil between the current or electric potential phase discrimination basis. When the two mutual inductance coil into the current and the resulting flux direction is the same, the two coils of the current into the end is called the same name end (also known as the same polarity end), and vice versa for the end of the different name.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15736 aligncenter\" title=\"9d4440d01d7c3c4ca45a889509575619\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d4440d01d7c3c4ca45a889509575619.png\" alt=\"9d4440d01d7c3c4ca45a889509575619\" width=\"473\" height=\"261\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d4440d01d7c3c4ca45a889509575619.png 656w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d4440d01d7c3c4ca45a889509575619-300x166.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d4440d01d7c3c4ca45a889509575619-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d4440d01d7c3c4ca45a889509575619-600x331.png 600w\" sizes=\"(max-width: 473px) 100vw, 473px\" \/>Figure 15-1 Circuit diagram with transformer<\/p>\n<p style=\"text-indent: 2em; margin-top: 25px;\">In the two coils shown in Fig. 15-2, the current in the left coil flows from end 1, and the current in the right coil flows from end 3. The direction of magnetic flux produced by the two coils is the same (mutually assisted),then ends 1 and 3 are homonymous, ends 2 and 4 are homonymous, ends 1 and 4 are heteronymous, and ends 2 and 3 are heteronymous.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15737 aligncenter\" title=\"c198cae55e031ab5731e05d578fa28d6\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6.png\" alt=\"c198cae55e031ab5731e05d578fa28d6\" width=\"503\" height=\"385\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6.png 986w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6-300x229.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6-768x587.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6-16x12.png 16w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c198cae55e031ab5731e05d578fa28d6-600x459.png 600w\" sizes=\"(max-width: 503px) 100vw, 503px\" \/>Figure 15-2 Transformer Coil Circuit Diagram<\/p>\n<p style=\"text-indent: 2em; margin-top: 25px;\">Also, as shown in Fig. 15-3, if the coils are wound in the same direction under the same core, the corresponding end is the homonymous end.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15738 aligncenter\" title=\"47fac4afc5a8e52967f8f40c10f2e669\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47fac4afc5a8e52967f8f40c10f2e669.png\" alt=\"47fac4afc5a8e52967f8f40c10f2e669\" width=\"485\" height=\"267\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47fac4afc5a8e52967f8f40c10f2e669.png 748w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47fac4afc5a8e52967f8f40c10f2e669-300x165.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47fac4afc5a8e52967f8f40c10f2e669-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47fac4afc5a8e52967f8f40c10f2e669-600x330.png 600w\" sizes=\"(max-width: 485px) 100vw, 485px\" \/>Figure 15-3 Judgment of coils with the same name under the same core<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 50px;\">2. Methods of determining the homonymous end of a transformer<\/h3>\n<p style=\"text-indent: 2em;\">Transformer homonymous end of the judgment method has a variety of methods, two of the commonly used methods are AC voltage method and DC method (divided into dry cell method, LED lamp method).<\/p>\n<div style=\"margin-top: 30px; border: 1px solid #ddd; border-radius: 10px; overflow: hidden;\">\n<div style=\"background: #1f365c; color: white; padding: 12px 20px; font-weight: bold;\">(1) AC voltage method<\/div>\n<div style=\"padding: 25px;\">\n<p style=\"text-indent: 2em;\">In the AC voltage method, the original and secondary side windings of a single-phase transformer are first connected (as shown in Figure 15-4), and then an appropriate AC voltage is applied to the primary side. Through the voltmeter to measure the original and secondary side of the voltage U<sub>1<\/sub>U<sub>2<\/sub>, and the voltage between the terminals of 3 and 4, U<sub>3<\/sub>. If U<sub>3<\/sub> is equal to U<sub>1<\/sub> with U<sub>2<\/sub> sum, then ends 2 and 3 of the wire are the same name. If U<sub>3<\/sub> is equal to U<sub>1<\/sub> with U<sub>2<\/sub> The difference between the two is the same name for ends 1 and 3 of the wire.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15739 aligncenter\" title=\"8f0da51b9649dc684ad04fbc5a258a36\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8f0da51b9649dc684ad04fbc5a258a36.png\" alt=\"8f0da51b9649dc684ad04fbc5a258a36\" width=\"326\" height=\"157\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8f0da51b9649dc684ad04fbc5a258a36.png 474w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8f0da51b9649dc684ad04fbc5a258a36-300x144.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8f0da51b9649dc684ad04fbc5a258a36-18x9.png 18w\" sizes=\"(max-width: 326px) 100vw, 326px\" \/>Figure 15-4 AC Voltage Method for Measuring Transformer Homonymous Terminals<\/p>\n<\/div>\n<\/div>\n<div style=\"margin-top: 30px; border: 1px solid #ddd; border-radius: 10px; overflow: hidden;\">\n<div style=\"background: #ef9308; color: white; padding: 12px 20px; font-weight: bold;\">(2) DC method (dry cell method and LED lamp method)<\/div>\n<div style=\"padding: 25px;\">\n<p><strong>:: Direct current method (dry cell method):<\/strong><\/p>\n<p style=\"text-indent: 2em;\">Connect a dry cell battery and a multimeter to the circuit as shown in Figure 15-5. Set the multimeter to a low DC voltage (e.g., below 5V), or a low DC current (e.g., 5mA). At the moment of turning on the switch, if the needle deflects positively, the positive terminal of the multimeter and the positive terminal of the battery are connected to the same name; if the needle deflects negatively, the positive terminal of the multimeter and the negative terminal of the battery are connected to the same name.<strong>Note that when the switch is disconnected, the meter needle swings in the other direction, so the switch should not be left on for long periods of time.<\/strong><\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-bottom: 30px;\"><img decoding=\"async\" class=\"wp-image-15740 aligncenter\" title=\"4303acd8da2ea0602dadd451c82e8ef2\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4303acd8da2ea0602dadd451c82e8ef2.png\" alt=\"4303acd8da2ea0602dadd451c82e8ef2\" width=\"263\" height=\"114\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4303acd8da2ea0602dadd451c82e8ef2.png 434w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4303acd8da2ea0602dadd451c82e8ef2-300x130.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4303acd8da2ea0602dadd451c82e8ef2-18x8.png 18w\" sizes=\"(max-width: 263px) 100vw, 263px\" \/>Figure 15-5 DC method (dry cell method) to measure the transformer homonymous terminal<\/p>\n<p><strong>\u25cf DC method (LED lamp method):<\/strong><\/p>\n<p style=\"text-indent: 2em;\">This is shown in Figure 15-6. To enhance the induced potential so that the neon tube can glow, we can connect the battery to the winding with fewer turns while connecting the stylus to the winding with more turns. When the button is pressed and then suddenly released, this creates a high induced potential in the winding with more turns, which excites the neon tube to glow. Watch carefully which end glows, as the glowing end is actually the negative end of the induced potential. In addition, the end that is connected to the positive terminal of the battery and to the glowing end of the neon tube is the end with the same name.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15741 aligncenter\" title=\"49a9d6af8a719c2e86026c305e44716c\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/49a9d6af8a719c2e86026c305e44716c.png\" alt=\"49a9d6af8a719c2e86026c305e44716c\" width=\"252\" height=\"122\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/49a9d6af8a719c2e86026c305e44716c.png 446w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/49a9d6af8a719c2e86026c305e44716c-300x145.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/49a9d6af8a719c2e86026c305e44716c-18x9.png 18w\" sizes=\"(max-width: 252px) 100vw, 252px\" \/>Figure 15-6 DC method (LED lamp method) to measure the transformer homonymous terminal<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">III. Use of voltage and current transformers<\/h2>\n<div style=\"margin-top: 30px; display: grid; grid-template-columns: 1fr 1fr; gap: 30px;\">\n<div style=\"background: #fdf2f2; border: 1px solid #f5c6cb; padding: 25px; border-radius: 12px;\">\n<h3 style=\"color: #721c24; margin-top: 0; border-bottom: 1px solid #f5c6cb; padding-bottom: 10px;\">(i) AC voltmeters and voltage transformers (PT)<\/h3>\n<ul style=\"padding-left: 20px; font-size: 14px;\">\n<li style=\"margin-bottom: 8px;\">(1) The voltmeter is connected in parallel to the terminals of the voltage to be measured.<\/li>\n<li style=\"margin-bottom: 8px;\">(2) Select the range of the voltmeter according to the size of the measured voltage and make its range slightly larger than the voltage of the object to be measured.<\/li>\n<li style=\"margin-bottom: 8px;\">(3) Voltage transformers are used when measuring high voltages with a voltmeter:\n<ul style=\"margin-top: 8px; font-weight: 500;\">\n<li>The primary side is connected to the measured voltage and the secondary side is connected to a voltmeter (standard voltage is 100 V); \u2460 The primary side is connected to the measured voltage and the secondary side to a voltmeter (standard voltage is 100 V).;<\/li>\n<li>\u2461 Ground the iron core;<\/li>\n<li style=\"color: #d9534f; font-weight: bold;\">\u2462 The secondary side of the voltage transformer is not allowed to be short-circuited.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div>\n<div style=\"background: #fff3cd; border: 1px solid #ffeeba; padding: 25px; border-radius: 12px;\">\n<h3 style=\"color: #856404; margin-top: 0; border-bottom: 1px solid #ffeeba; padding-bottom: 10px;\">(ii) AC ammeters and current transformers (CTs)<\/h3>\n<ul style=\"padding-left: 20px; font-size: 14px;\">\n<li style=\"margin-bottom: 8px;\">(1) An AC ammeter is connected in series with the circuit being measured.<\/li>\n<li style=\"margin-bottom: 8px;\">(2) Select the range of the ammeter according to the size of the measurement and make its range slightly larger than the object to be measured.<\/li>\n<li style=\"margin-bottom: 8px;\">(3) When the ammeter measures large currents, a suitable current transformer should be selected:\n<ul style=\"margin-top: 8px; font-weight: 500;\">\n<li>\u2460 The secondary side is connected to the ammeter, and the general head current is 5A;<\/li>\n<li>\u2461 When replacing the ammeter, short-circuit the secondary side to prevent the induction of high voltage burnt transformer;<\/li>\n<li>\u2462 Ground the secondary side and iron core to prevent leakage of electricity and jeopardize safety;<\/li>\n<li style=\"color: #d9534f; font-weight: bold;\">\u2463 The secondary side of the current transformer is not allowed to be open circuit.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 20px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electrical and Electronics Officer (ETO) Technical Training Material - Transformer Chapter - Revision 2026<\/footer>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Transformer Operation and Maintenance: From Fundamental Principles to Polarity Determination Technical Training Materials for Shipboard Electronics and Electrical Officers (ETO) A transformer is a stationary electrical device...<\/p>","protected":false},"author":1,"featured_media":15742,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15735","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15735"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15735\/revisions"}],"predecessor-version":[{"id":15743,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15735\/revisions\/15743"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15742"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15735"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15735"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}