{"id":15762,"date":"2026-01-06T22:31:11","date_gmt":"2026-01-06T14:31:11","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15762"},"modified":"2026-01-06T22:31:11","modified_gmt":"2026-01-06T14:31:11","slug":"diandongjiqidongxiangjiexiankongzhidianqixiangjieyu-y-jiangyaqidongshiwu","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/diandongjiqidongxiangjiexiankongzhidianqixiangjieyu-y-jiangyaqidongshiwu","title":{"rendered":"Motor Starter Cabinet Wiring: Detailed Explanation of Control Devices and Practical Y-\u0394 Voltage Reduction Starting"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Motor Starter Cabinet Wiring: Detailed Explanation of Control Devices and Practical Y-\u0394 Voltage Reduction Starting<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Ship's Electrical and Electronics Officer (ETO) Core Skills Practice<\/div>\n<\/div>\n<section style=\"margin-bottom: 40px; background: #f0f4f8; padding: 25px; border-radius: 8px; border-left: 10px solid #1f365c;\">\n<p style=\"text-indent: 2em; margin: 0; font-weight: 500;\">Motor starter box is a kind of electrical control device for controlling motor starting, running, stopping and providing protection function, which is composed of switchgear, relay, contactor and other control appliances. In motor starting control, according to different motor power and load characteristics, it usually adopts various starting methods such as direct starting, Y-\u25b3 voltage reduction starting, autotransformer voltage reduction starting, etc. This section will focus on Y-\u25b3 voltage reduction starting. This section will focus on the working principle and wiring method of Y-\u25b3 reduced voltage start.<\/p>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Control of electrical appliances<\/h2>\n<div style=\"margin-top: 30px; padding: 0 10px;\">\n<div style=\"margin-bottom: 40px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Buttons<\/h3>\n<p style=\"text-indent: 2em;\">Pushbutton is one of the most commonly used main electrical appliances, often used to connect or disconnect the current smaller control circuits, its structure is simple, the control is very convenient. Figure 16-11 shows the structure of the button and graphical symbols.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15763 aligncenter\" title=\"3d9a05f47dd33c93adab0e09d5eca3d5\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/3d9a05f47dd33c93adab0e09d5eca3d5.png\" alt=\"3d9a05f47dd33c93adab0e09d5eca3d5\" width=\"441\" height=\"146\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/3d9a05f47dd33c93adab0e09d5eca3d5.png 652w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/3d9a05f47dd33c93adab0e09d5eca3d5-300x99.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/3d9a05f47dd33c93adab0e09d5eca3d5-18x6.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/3d9a05f47dd33c93adab0e09d5eca3d5-600x199.png 600w\" sizes=\"(max-width: 441px) 100vw, 441px\" \/>Figure 16-11 Pushbutton Structure Diagram and Graphical Symbols<\/p>\n<div style=\"background: #fdf2f2; border: 1px solid #f5c6cb; padding: 20px; border-radius: 8px; margin-top: 15px;\"><strong style=\"color: #c0392b;\">Safety color-coded norms:<\/strong><\/p>\n<p style=\"margin-top: 5px; font-size: 14px;\">The color of the color code of the control button represents the function of the button, \u201cStop\u201d button must be red; \u201cEmergency Stop\u201d button must be red mushroom head type; \u201cStart\u201d button must have a protective retaining ring, the protective retaining ring should be higher than the button head in order to prevent the accidental touch of the false action. The \"start\" button must have a protective retaining ring, which should be higher than the head of the button to prevent it from being accidentally triggered to produce false action.<\/p>\n<\/div>\n<\/div>\n<div style=\"margin-bottom: 40px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(ii) AC contactors<\/h3>\n<p style=\"text-indent: 2em;\">AC contactor is a kind of automatic electrical appliance relying on electromagnetic force to make the contacts close or separate, which is used to turn on and off the motor or other important electrical appliances of electric equipment. As shown in Figure 16-12, it is mainly composed of iron core, contacts and coils, of which the iron core is divided into static iron core and dynamic iron core, and the contacts are divided into main contacts and auxiliary contacts.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15764 aligncenter\" title=\"049194d02455fb19ca442fd73ab35871\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871.png\" alt=\"049194d02455fb19ca442fd73ab35871\" width=\"548\" height=\"262\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871.png 1046w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871-300x143.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871-1024x489.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871-768x367.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871-18x9.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/049194d02455fb19ca442fd73ab35871-600x287.png 600w\" sizes=\"(max-width: 548px) 100vw, 548px\" \/>Figure 16-12 AC Contactor<\/p>\n<\/div>\n<div style=\"margin-bottom: 40px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(iii) Fuses<\/h3>\n<p style=\"text-indent: 2em;\">Fuses are used in low-voltage distribution systems and control systems, mainly for short-circuit and over-current protection. When the current through the fuse is greater than the specified value, the heat generated melts the melt and automatically breaks the circuit. When used, the fuse is connected in series in the protected circuit, in the circuit short-circuit or serious overcurrent quickly and automatically fuse, so as to cut off the circuit power to play a protective role.<\/p>\n<p style=\"text-indent: 2em;\">Fuses are mainly composed of two parts: the fuse (fuse wire) and the fuse tube (or fuse holder). There are many types of fuses, commonly used insertion fuse, spiral fuse, closed tube fuse. Figure 16-13 shows the spiral fuse structure and symbols.<\/p>\n<\/div>\n<div style=\"margin-bottom: 40px;\">\n<div id=\"attachment_15765\" style=\"width: 494px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15765\" class=\"wp-image-15765\" title=\"\u56fe16-13  \u87ba\u65cb\u5f0f\u7194\u65ad\u5668\u7ed3\u6784\u56fe\u548c\u7b26\u53f7\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab.png\" alt=\"\u56fe16-13  \u87ba\u65cb\u5f0f\u7194\u65ad\u5668\u7ed3\u6784\u56fe\u548c\u7b26\u53f7\" width=\"484\" height=\"284\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab.png 774w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab-300x176.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab-768x450.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab-18x12.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/660c0370518f3c3a3962fdfda3fa74ab-600x352.png 600w\" sizes=\"(max-width: 484px) 100vw, 484px\" \/><p id=\"caption-attachment-15765\" class=\"wp-caption-text\">Figure 16-13 Screw Fuse Construction Diagram and Symbols<\/p><\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(iv) Relays<\/h3>\n<h4 style=\"color: #1f365c; font-weight: bold;\">1. Overcurrent relays<\/h4>\n<p style=\"text-indent: 2em;\">Overcurrent relay is a kind of overcurrent relay with overload protection characteristics, commonly used in motor operation overload protection, its shape, structure principle and symbols shown in Figure 16-14. It is the use of the thermal effect of the current and action, when the motor overload, will make the overcurrent relay heating element heat, causing bimetal bending, push the guide plate to make the control circuit connected to the movable break contact break, so that the contactor coil is also de-energized, through the main contacts of the contactor to break the main circuit of the motor, in order to achieve the purpose of overload protection.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15766 aligncenter\" title=\"0639121bf4401fa3e608c979fbbe47e3\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3.png\" alt=\"0639121bf4401fa3e608c979fbbe47e3\" width=\"415\" height=\"218\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3.png 858w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3-300x157.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3-768x403.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3-18x9.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0639121bf4401fa3e608c979fbbe47e3-600x315.png 600w\" sizes=\"(max-width: 415px) 100vw, 415px\" \/>Figure 16-14 Overcurrent Relay Shape, Principle of Construction, and Symbols<\/p>\n<h4 style=\"color: #1f365c; font-weight: bold; margin-top: 30px;\">2. Time relays<\/h4>\n<p style=\"text-indent: 2em;\">Time relays are characterized by a delayed action of the contacts after receiving or losing an electrical signal. It has electromagnetic, air-damped, electric, pendulum and semiconductor types. According to its action requirements in the line, usually can be divided into four types of delayed break contacts, delayed break contacts, delayed break contacts, delayed close contacts, delayed close contacts, delayed break contacts. The action requirements and graphical symbols of each type of contact are shown in Figure 16-15.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15767 aligncenter\" title=\"f322ef1e35a4c5b8dcc78fce02b7e5b0\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f322ef1e35a4c5b8dcc78fce02b7e5b0.png\" alt=\"f322ef1e35a4c5b8dcc78fce02b7e5b0\" width=\"291\" height=\"222\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f322ef1e35a4c5b8dcc78fce02b7e5b0.png 522w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f322ef1e35a4c5b8dcc78fce02b7e5b0-300x229.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f322ef1e35a4c5b8dcc78fce02b7e5b0-16x12.png 16w\" sizes=\"(max-width: 291px) 100vw, 291px\" \/>Figure 16-15 Motion Requirements and Graphic Symbols for Various Contacts<\/p>\n<h4 style=\"color: #1f365c; font-weight: bold; margin-top: 40px; background: #eef2f7; padding: 15px; border-radius: 4px;\">3. AH3-3 Parameterization and Wiring of Time Relays<\/h4>\n<div style=\"padding: 15px;\">\n<p><strong>(1) Parameter setting:<\/strong>As shown in Figure 16-16, the AH3-3 time relay can be seen by removing the setting knob, removing the scale plate (there are several scale plates), there is an internal changeover switch for switching gears, referring to the nameplate toggle the changeover switch to the gear corresponding to the minutes (MIN), and then installing the scale plate and knob back.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15768 aligncenter\" title=\"78c528dd831e01ab24fa8d1f969ba12c\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/78c528dd831e01ab24fa8d1f969ba12c.png\" alt=\"78c528dd831e01ab24fa8d1f969ba12c\" width=\"407\" height=\"232\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/78c528dd831e01ab24fa8d1f969ba12c.png 652w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/78c528dd831e01ab24fa8d1f969ba12c-300x171.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/78c528dd831e01ab24fa8d1f969ba12c-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/78c528dd831e01ab24fa8d1f969ba12c-600x342.png 600w\" sizes=\"(max-width: 407px) 100vw, 407px\" \/>Figure 16-16 AH3-3 Time Relay Physical Panel<\/p>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px; margin-top: 20px;\">\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong>(2) Preparation before wiring:<\/strong>Prepare a screwdriver, the appropriate size wire (according to the size of the load current selection, generally copper wire, the current is larger when the selection of thicker wire diameter wire), wire strippers and other tools.<\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong>(3) Security measures:<\/strong>Ensure that the relevant power supply has been disconnected before the wiring operation, you can use an electric pen and other tools to detect and confirm that there is no electricity, and do a good job of safety protection to avoid electric shock accidents.<\/div>\n<\/div>\n<p style=\"margin-top: 25px;\"><strong>(4) Understanding Relay Terminals:<\/strong>Familiarize yourself with the function of each terminal of the AH3-3 time relay. As shown in Figure 16-17, 1, 3, and 4 are non-delay contacts, and 5, 6, and 8 are delay contacts.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"wp-image-15769 aligncenter\" title=\"d9be362e7313b82e72c820b0fe8e5dc8\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d9be362e7313b82e72c820b0fe8e5dc8.png\" alt=\"d9be362e7313b82e72c820b0fe8e5dc8\" width=\"228\" height=\"374\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d9be362e7313b82e72c820b0fe8e5dc8.png 306w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d9be362e7313b82e72c820b0fe8e5dc8-183x300.png 183w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/d9be362e7313b82e72c820b0fe8e5dc8-7x12.png 7w\" sizes=\"(max-width: 228px) 100vw, 228px\" \/>Figure 16-17 AH3-3 Time Relay Terminal Blocks<\/p>\n<p style=\"margin-top: 20px;\"><strong>(5) Power wiring:<\/strong>Find the terminals 2 and 7 labeled power input; if the working power is AC power and the voltage is 220 V, connect the AC power's fire wire to terminal 2 and the zero wire to terminal 7; if the working power is DC power, pay attention to the positive and negative poles, and connect them to the corresponding power terminals correctly, with the positive pole connecting to terminal 7, and the negative pole connecting to terminal 2, and make sure that the power supply voltage is the same as the rated voltage of the relay.<\/p>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px; margin-top: 20px; box-shadow: 0 4px 10px rgba(0,0,0,0.05);\"><strong style=\"color: #1f365c; font-size: 16px;\">(6) Contact wiring (refer to Figure 16-17):<\/strong><\/p>\n<ul style=\"margin-top: 10px; font-size: 14px;\">\n<li style=\"margin-bottom: 10px;\"><strong>\u2460 Delayed closing (normally open contact)<\/strong>If used to control a motor with delayed start, the delayed closure function is required. Find the terminal 6 and 8 corresponding to the delayed closing contact, connect one end of the load to terminal 6 and the other end to the corresponding end of the power supply.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>\u2461 Delayed disconnection (normally closed contact)<\/strong>If it is used to control the motor to stop at a delayed time, it is necessary to use the time-delayed disconnect function. Locate the terminals 5 and 8 corresponding to the delay break contacts, connect one end of the load to terminal 5 and the other end to the corresponding end of the power supply.<\/li>\n<li><strong>\u2462 Instantaneous contact wiring<\/strong>: Instantaneous contacts 1 and 3 can be used for some control logic that requires immediate action. For example, by connecting the instantaneous contact to the alarm indicator, the indicator lights up immediately at the moment the time relay is energized, connect one end of the indicator to terminal 1 and the other end to the corresponding end of the power supply.<\/li>\n<\/ul>\n<\/div>\n<p style=\"margin-top: 25px;\"><strong>(7) Wiring Inspection and Testing:<\/strong><\/p>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px;\">\n<div style=\"background: #fdf6ec; padding: 15px; border-radius: 6px;\"><strong>\u2460 Inspection<\/strong>: Check carefully whether all wiring is firm, with no loose or false connections; check whether the terminals are connected correctly to avoid short circuits and disconnections; and confirm that the wiring complies with the relevant electrical codes and safety requirements.<\/div>\n<div style=\"background: #fdf6ec; padding: 15px; border-radius: 6px;\"><strong>\u2461 Testing<\/strong>: After confirming that the wiring is correct, turn on the power and observe whether the time relay operates according to the set time. Check whether the delay contact switches the state accurately after the set time arrives, and whether the instantaneous contact acts normally at the moment of power-on; observe whether the load equipment works as expected. If any abnormality occurs, immediately disconnect the power and recheck the wiring and setting parameters.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Second, the three-phase asynchronous motor Y-\u25b3 connection conversion wiring<\/h2>\n<div style=\"margin-top: 30px; padding: 0 10px;\">\n<p style=\"text-indent: 2em;\">Y-\u25b3 reduced voltage starting control line technology is mature and has been made into special starting equipment, such as QX3 series. When starting, the stator winding is firstly connected into star, and when the speed rises to near rated speed, the stator winding is connected into triangle, and the motor enters into normal operation.<\/p>\n<p style=\"text-indent: 2em;\">Figure 16-18 shows the Y-\u0394 connection conversion wiring for a three-phase asynchronous motor. The circuit uses three contactors and a time relay. Contactor KM introduces the three-phase power supply; KM\u2083 connects the stator three-phase winding into a delta; KM\u2082 connects the stator three-phase winding into a star; and the time relay acts as a time delay to convert the star connection into a delta connection.<\/p>\n<p style=\"text-align: center; font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15770 aligncenter\" title=\"7f1955f4037476a35c56af27648fb900\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7f1955f4037476a35c56af27648fb900.png\" alt=\"7f1955f4037476a35c56af27648fb900\" width=\"495\" height=\"332\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7f1955f4037476a35c56af27648fb900.png 712w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7f1955f4037476a35c56af27648fb900-300x201.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7f1955f4037476a35c56af27648fb900-18x12.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7f1955f4037476a35c56af27648fb900-600x403.png 600w\" sizes=\"(max-width: 495px) 100vw, 495px\" \/>Figure 16-18 Three-phase asynchronous motor Y-\u25b3 connection conversion wiring<\/p>\n<div style=\"margin-top: 30px; background: #fff8e6; border: 1px solid #ffeeba; padding: 25px; border-radius: 8px;\">\n<p style=\"margin: 0; text-indent: 2em;\">If you want to limit the starting current without lowering the starting torque, you can use a wire-wound three-phase asynchronous motor. When starting, a starting resistor or frequency sensitive varistor is strung in the rotor circuit; when starting is completed, the starting resistor or frequency sensitive varistor strung in the rotor circuit is automatically removed by the control circuit.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Basic Marine Electrical &amp; Electronic Skills Training | Starter Box Wiring Practices | 2026 Revision<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Motor Starter Cabinet Wiring: Detailed Explanation of Control Devices and Y-\u0394 Voltage Reduction Starting Practices Core Skills Practical Training for Marine Electronics and Electrical Officers (ETO) Motor Starter Cabinet...<\/p>","protected":false},"author":1,"featured_media":15771,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15762","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15762"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15762\/revisions"}],"predecessor-version":[{"id":15772,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15762\/revisions\/15772"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15771"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15762"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15762"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}