{"id":15773,"date":"2026-01-07T09:14:42","date_gmt":"2026-01-07T01:14:42","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15773"},"modified":"2026-01-07T09:15:39","modified_gmt":"2026-01-07T01:15:39","slug":"chuanyongdianlanshibieyugenghuanquangongluedianlikongzhiyuxinhaodianlanfenleijishicaoliucheng","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/chuanyongdianlanshibieyugenghuanquangongluedianlikongzhiyuxinhaodianlanfenleijishicaoliucheng","title":{"rendered":"Marine cable identification and replacement of the whole strategy: power, control and signal cable classification and practical procedures"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Marine Cable Identification and Replacement Specification Guide<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Marine Electrical Practices - Maintenance and Replacement Standards<\/div>\n<\/div>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Cable classification<\/h2>\n<p style=\"margin-top: 20px; text-indent: 2em;\">Marine cables are mainly divided into marine power cables, marine control cables, marine signal cables.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px; margin-top: 25px;\">\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee; text-align: center;\">\n<h3 style=\"color: #1f365c; font-size: 18px; margin-top: 0;\">1. Marine power cables<\/h3>\n<p style=\"text-align: left; font-size: 14px;\">Marine power cables, as shown in Figure 17-1, including rated voltage AC frequency in 1kV and below the low-voltage power cables and rated voltage AC frequency in 3 ~ 15kV medium-voltage power cables.<\/p>\n<div id=\"attachment_15774\" style=\"width: 225px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15774\" class=\"wp-image-15774\" title=\"Figure 17-1: Physical structure of marine LV and MV power cables\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3.png\" alt=\"Figure 17-1: Physical structure of marine LV and MV power cables\" width=\"215\" height=\"69\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3.png 808w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3-300x97.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3-768x247.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3-18x6.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/47793c632869b70530a789ffc03efcd3-600x193.png 600w\" sizes=\"(max-width: 215px) 100vw, 215px\" \/><p id=\"caption-attachment-15774\" class=\"wp-caption-text\">Figure 17-1: Physical structure of marine LV and MV power cables<\/p><\/div>\n<\/div>\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee; text-align: center;\">\n<h3 style=\"color: #1f365c; font-size: 18px; margin-top: 0;\">2. Marine control cables<\/h3>\n<p style=\"text-align: left; font-size: 14px;\">Marine control cables, as shown in Figure 17-2, are control cables specifically designed for use in marine environments, with special structural and performance requirements to meet the needs of ships in complex and demanding conditions.<\/p>\n<div id=\"attachment_15776\" style=\"width: 149px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15776\" class=\"wp-image-15776\" title=\"Figure 17-2 Marine control cables\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/42cc8ff7838db020452abeaa49412442-1.png\" alt=\"Figure 17-2 Marine control cables\" width=\"139\" height=\"90\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/42cc8ff7838db020452abeaa49412442-1.png 520w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/42cc8ff7838db020452abeaa49412442-1-300x194.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/42cc8ff7838db020452abeaa49412442-1-18x12.png 18w\" sizes=\"(max-width: 139px) 100vw, 139px\" \/><p id=\"caption-attachment-15776\" class=\"wp-caption-text\">Figure 17-2 Marine control cables<\/p><\/div>\n<\/div>\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee; text-align: center;\">\n<h3 style=\"color: #1f365c; font-size: 18px; margin-top: 0;\">3. Marine signal cables<\/h3>\n<p style=\"text-align: left; font-size: 14px;\">Marine signal cable is shown in Figure 17-3. Marine signal cable is a kind of marine cable used for signal transmission and control system in ship communication, electronic computer and information processing equipment.<\/p>\n<div id=\"attachment_15777\" style=\"width: 174px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15777\" class=\"wp-image-15777\" title=\"Figure 17-3 Marine signal cable\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0712faa135741327b8c7b2b6db378b1c.png\" alt=\"Figure 17-3 Marine signal cable\" width=\"164\" height=\"96\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0712faa135741327b8c7b2b6db378b1c.png 528w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0712faa135741327b8c7b2b6db378b1c-300x175.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/0712faa135741327b8c7b2b6db378b1c-18x12.png 18w\" sizes=\"(max-width: 164px) 100vw, 164px\" \/><p id=\"caption-attachment-15777\" class=\"wp-caption-text\">Figure 17-3 Marine signal cable<\/p><\/div>\n<\/div>\n<\/div>\n<p style=\"margin-top: 15px; font-weight: bold; color: #c0392b;\">Note: Usually there is limited space for laying marine cables.<\/p>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">II. Cable identification<\/h2>\n<div style=\"margin-top: 30px;\">\n<p style=\"text-indent: 2em;\">The main components of a marine cable are shown in Figure 17-4.<\/p>\n<div style=\"text-align: center; margin: 30px 0;\">\n<div id=\"attachment_15778\" style=\"width: 413px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15778\" class=\"wp-image-15778\" title=\"Figure 17-4: Multi-layer construction of a marine cable with conductor insulation and shielding and outer jacket\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/90f64028dd96c4302b38f3b0a2d17bcd.png\" alt=\"Figure 17-4: Multi-layer construction of a marine cable with conductor insulation and shielding and outer jacket\" width=\"403\" height=\"301\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/90f64028dd96c4302b38f3b0a2d17bcd.png 594w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/90f64028dd96c4302b38f3b0a2d17bcd-300x224.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/90f64028dd96c4302b38f3b0a2d17bcd-16x12.png 16w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><p id=\"caption-attachment-15778\" class=\"wp-caption-text\">Figure 17-4: Multi-layer construction of a marine cable with conductor insulation and shielding and outer jacket<\/p><\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #ddd; border-radius: 12px; padding: 25px; box-shadow: 0 4px 15px rgba(0,0,0,0.05);\">\n<ul style=\"list-style-type: none; padding-left: 0;\">\n<li style=\"margin-bottom: 20px; display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 15px; flex-shrink: 0; font-size: 14px;\">1<\/span>\n<div><strong>Conductor (wire):<\/strong>Refers to the material used as wire, cable, generally made of copper or aluminum wire, but also made of silver wire (conductive, thermal good), used to transmit current.<\/div>\n<\/li>\n<li style=\"margin-bottom: 20px; display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 15px; flex-shrink: 0; font-size: 14px;\">2<\/span>\n<div><strong>Insulation:<\/strong>Conductors are usually surrounded by a layer of insulating material to isolate the current and prevent short circuits. Common insulating materials include polyvinyl chloride (PVC) and polyethylene (PE), polyurethane (PUR), TPE, TPV, and others.<\/div>\n<\/li>\n<li style=\"margin-bottom: 20px; display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 15px; flex-shrink: 0; font-size: 14px;\">3<\/span>\n<div><strong>Lining layer:<\/strong>The outside of the cable is usually wrapped with a sheath to protect the internal components from physical damage and environmental influences.<\/div>\n<\/li>\n<li style=\"margin-bottom: 20px; display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 15px; flex-shrink: 0; font-size: 14px;\">4<\/span>\n<div><strong>Shield:<\/strong>The shielding layer is designed to ensure that the transmission performance of the system in an environment with electromagnetic interference has anti-interference properties. Here the anti-interference should include two aspects, namely, the ability to resist external electromagnetic interference and the ability of the system itself to radiate electromagnetic interference to the outside.<\/div>\n<\/li>\n<li style=\"display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 15px; flex-shrink: 0; font-size: 14px;\">5<\/span>\n<div><strong>Outer Sheath:<\/strong>Cables are usually wrapped with a sheath to protect the internal components from physical damage and environmental influences. The material of the outer sheath depends on the application of the cable, and is usually PVC, PUR, TPV, etc.<\/div>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">III. Replacement of cables<\/h2>\n<p style=\"margin-top: 20px; text-indent: 2em;\">Cable replacement is a multi-step process that requires careful handling to ensure safety and effectiveness. Below are the main steps in cable replacement.<\/p>\n<div style=\"margin-top: 30px; display: flex; flex-direction: column; gap: 20px;\">\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px;\">\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">1. Material preparation<\/h4>\n<p style=\"font-size: 14px;\">Prepare cables of the same type and length as the original cable (if not of the same type and manufacturer, confirm the new cable's insulation level, fire resistance level, cable diameter, copper core type, and other conditions that may affect the use of the requirements), and prepare the corresponding auxiliary materials, such as insulating tape, cable numbering tubes, cable ties, heat-shrinkable tubing, etc., as shown in Figure 17-5.<\/p>\n<div style=\"text-align: center; margin-top: 15px;\">\n<div id=\"attachment_15779\" style=\"width: 334px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15779\" class=\"wp-image-15779\" title=\"Figure 17-5: Common Accessories for Cable Replacement: Heat Shrink Tubing Wire Gauge Ties\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/06b6eab64a57bf7ae45ab02d327b4a99.png\" alt=\"Figure 17-5: Common Accessories for Cable Replacement: Heat Shrink Tubing Wire Gauge Ties\" width=\"324\" height=\"143\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/06b6eab64a57bf7ae45ab02d327b4a99.png 634w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/06b6eab64a57bf7ae45ab02d327b4a99-300x132.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/06b6eab64a57bf7ae45ab02d327b4a99-18x8.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/06b6eab64a57bf7ae45ab02d327b4a99-600x265.png 600w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><p id=\"caption-attachment-15779\" class=\"wp-caption-text\">Figure 17-5: Common Accessories for Cable Replacement: Heat Shrink Tubing Wire Gauge Ties<\/p><\/div>\n<\/div>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px; border-top: 4px solid #c0392b;\">\n<h4 style=\"color: #c0392b; margin-top: 0;\">2. Power cuts and warning signs<\/h4>\n<p style=\"font-size: 14px;\">Before replacing cables, ensure that the power supply is completely disconnected to avoid the risk of electric shock. Hang warning signs as shown in Figure 17-6.<\/p>\n<div style=\"text-align: center; margin-top: 15px;\">\n<div id=\"attachment_15780\" style=\"width: 182px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-15780\" class=\"wp-image-15780\" title=\"Figure 17-6: Electrical Maintenance Safety Warning Sign: No One Working on Closed Gate\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5ac9126dd336192f17ff2b1837d2a969.png\" alt=\"Figure 17-6: Electrical Maintenance Safety Warning Sign: No One Working on Closed Gate\" width=\"172\" height=\"165\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5ac9126dd336192f17ff2b1837d2a969.png 440w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5ac9126dd336192f17ff2b1837d2a969-300x288.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5ac9126dd336192f17ff2b1837d2a969-13x12.png 13w\" sizes=\"(max-width: 172px) 100vw, 172px\" \/><p id=\"caption-attachment-15780\" class=\"wp-caption-text\">Figure 17-6: Electrical Maintenance Safety Warning Sign: No One Working on Closed Gate<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"background: #eef2f7; padding: 25px; border-radius: 12px;\">\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px;\">\n<div>\n<p><strong>3. Remove old cables:<\/strong>Use a suitable tool to remove the connector of the old cable and separate it from the unit.<\/p>\n<p><strong>4. Installation of new cables:<\/strong>Plug the new cable into the device connector to ensure a secure connection. Secure the cable with a cable tie or clip to prevent loosening.<\/p>\n<\/div>\n<div>\n<p><strong>5. Energized test:<\/strong>After the cable installation is completed, carry out an energization test to check that the new cable is working properly. Perform insulation tests and electrical tests to ensure the quality and safety of the cables.<\/p>\n<p><strong>6. Testing and acceptance:<\/strong>Use specialized equipment to test the circuits to ensure there are no safety hazards.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"background: #fdf6ec; border: 1px solid #ef9308; padding: 20px; border-radius: 8px;\">\n<p style=\"margin: 0; font-size: 15px; color: #856404;\">During the whole replacement process, safety operation procedures should be strictly observed, personal protective equipment should be equipped, and good site ventilation should be ensured. At the same time, construction quality inspection should be carried out after the construction is completed, and the construction process should be recorded for future reference and maintenance.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Basic Skills Training in Marine Electronics &amp; Electricity | Cable Management &amp; Practice | Revision 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Marine Cable Identification and Replacement Specification Guide Marine Electrical Hands-on - Maintenance and Replacement Standards I. Cable Classification Marine cables are mainly categorized into marine power cables, marine ...<\/p>","protected":false},"author":1,"featured_media":15781,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15773","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15773"}],"version-history":[{"count":2,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15773\/revisions"}],"predecessor-version":[{"id":15783,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15773\/revisions\/15783"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15781"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15773"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15773"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}