{"id":15801,"date":"2026-01-07T09:54:41","date_gmt":"2026-01-07T01:54:41","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15801"},"modified":"2026-01-07T09:54:41","modified_gmt":"2026-01-07T01:54:41","slug":"duanluqijiechuqijidianqirongduanqidiancizhidongqidechaizhuangjixiuli","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/duanluqijiechuqijidianqirongduanqidiancizhidongqidechaizhuangjixiuli","title":{"rendered":"Disassembly and repair of circuit breakers, contactors, relays, fuses and electromagnetic brakes"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Disassembly and repair of circuit breakers, contactors, relays, fuses and electromagnetic brakes<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Section 1: Disassembly and Repair of Circuit Breakers<\/div>\n<\/div>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Composition of circuit breakers<\/h2>\n<p style=\"margin-top: 20px; text-indent: 2em; background: #f9f9f9; padding: 20px; border-radius: 4px;\">Circuit breaker is a kind of not only can connect, break the circuit, but also the load circuit for automatic protection of switching appliances, because the arc extinguishing medium for the air, so also known as \u201cair switch\u201d. Circuit breaker in the circuit for overload (overcurrent), short-circuit protection, that is, in the overload or short-circuit automatically break the circuit. Circuit breakers are generally composed of contact system, arc extinguishing device, free release mechanism, operation drive, protection elements and locking device.<\/p>\n<div style=\"margin-top: 30px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">1. Contact systems<\/h3>\n<p style=\"text-indent: 2em;\">(1) Contacts are used to turn circuits on and off. The operating current of the contact system is very high, and it is necessary to cut off a large amount of current in case of a short-circuit fault, so usually each phase of the circuit contains two or three contacts connected in parallel with each other (i.e., the main contact, the subcontact and the arc contact).<\/p>\n<p style=\"text-indent: 2em;\">(2) The role of the main contact is to conduct large currents, the role of the arc contact is to withstand the mechanical impact and arc burns; vice contacts play a role in the transition buffer.<\/p>\n<div style=\"background: #fff8e6; padding: 20px; border-radius: 8px; border: 1px solid #ffeeba; margin: 20px 0;\">\n<p style=\"margin: 0; font-weight: bold; color: #856404;\">\u26a0\ufe0f Action Sequence Logic:<\/p>\n<ul style=\"margin-top: 10px; font-size: 15px;\">\n<li><strong>Wiring order:<\/strong>Arc contacts first \u2794 then secondary contacts \u2794 and finally main contacts;<\/li>\n<li><strong>Disconnect sequence:<\/strong>Primary contacts \u2794 then secondary contacts \u2794 and finally arc contacts.<\/li>\n<\/ul>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">2. Arc extinguishing devices<\/h3>\n<p style=\"text-indent: 2em;\">(1) automatic air circuit breaker most of the arc extinguishing grid for arc extinguishing, arc extinguishing device consists of a number of different lengths of ferrous (magnetic steel sheet) grids and insulating materials composed of arc extinguishing cover.<\/p>\n<p style=\"text-indent: 2em;\">(2) Relying on electromagnetic force, the arc will be sucked into the grid, divided into many short segments, so as to realize rapid arc extinguishing.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">3. Free release mechanism<\/h3>\n<p style=\"text-indent: 2em;\">(1) The function of the free release mechanism is to keep the contacts closed or to disconnect them quickly. It is the linking mechanism between the contact system and the operating drive;<\/p>\n<p style=\"text-indent: 2em;\">(2) The free release mechanism has three states: closing, parting (release), and ready to close (reclosing), as shown in figure 19-1.<\/p>\n<div style=\"text-align: center; margin: 30px 0;\">\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"aligncenter wp-image-15802\" title=\"Circuit Breaker Free Release Mechanism Closing Breaking Re-buckling Three-State Schematic Diagram\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56.png\" alt=\"Circuit Breaker Free Release Mechanism Closing Breaking Re-buckling Three-State Schematic Diagram\" width=\"472\" height=\"160\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56.png 862w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56-300x102.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56-768x260.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56-18x6.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d350707244dae6e8134e33da1f25a56-600x203.png 600w\" sizes=\"(max-width: 472px) 100vw, 472px\" \/>Figure 19-1 Three states of the free release mechanism<\/p>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">4. Operation of the transmission<\/h3>\n<p style=\"text-indent: 2em;\">The operating transmission device has manual operation, electromagnetic or electric operation and other ways. Regardless of which mode of operation is used, it is necessary to first enable the energy storage spring to store energy and make the free release mechanism reclosing, and then utilize the stored energy of the spring to quickly close the circuit breaker, even though the time of closing the circuit breaker has nothing to do with the operation, but only with the internal mechanism of the circuit breaker.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">5. Protection elements<\/h3>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 20px; margin-top: 20px;\">\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c;\">\n<p style=\"font-size: 14px; margin: 0;\">(1) Universal automatic air circuit breakers are usually provided with three strippers as protection elements: overcurrent stripper, loss of voltage stripper and shunt stripper.<\/p>\n<\/div>\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px; border-top: 4px solid #1f365c;\">\n<p style=\"font-size: 14px; margin: 0;\">(2) <strong>overcurrent detent<\/strong>The function is to realize the short circuit and overload protection for the main circuit.<\/p>\n<\/div>\n<\/div>\n<div style=\"margin-top: 20px; background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 8px;\">\n<p><strong>(3) Loss-of-voltage disconnectors:<\/strong>Realize loss of voltage and undervoltage protection. Ensure that when the voltage drops to 40% or below of the rated voltage value, it must act to disconnect the air circuit breaker, and when it is 75% or above of the rated voltage, it must ensure that the air circuit breaker is closed reliably, therefore, the loss of voltage protection can be rectified at 35% to 70% of the rated voltage. In fact, the loss-of-voltage detent generally consists of an instantaneous-acting voltage relay, and when the line voltage is lower than a certain set value, the relay is released due to insufficient electromagnetic suction, and the switch is automatically tripped through the free-release mechanism.<\/p>\n<p><strong>(4) Separate excitation disconnectors:<\/strong>Realize remote control shunt operation (remote shunt operation). The shunt release coil should be able to trip the air circuit breaker at the rated voltage of 75% to 110%.<\/p>\n<p style=\"margin-bottom: 0;\"><strong>(5) Other:<\/strong>Some universal automatic air circuit breakers are also equipped with thermal disconnectors, reverse power disconnectors and other protective devices.<\/p>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">6. Locking devices<\/h3>\n<p style=\"text-indent: 2em;\">In an emergency, even though there may be some damage to the electrical equipment, it is necessary to force the supply of power without wanting the switch to actuate. In this case, the locking device can be placed in the \u201csnap\u201d position to lock the striker.<\/p>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Air Circuit Breaker Adjustment<\/h2>\n<div style=\"margin-top: 30px; padding: 0 10px;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: flex-start;\">\n<div style=\"flex: 1; min-width: 320px;\">\n<p>(1) Recognize the outline of the main switch, the closing pushbutton, the breaking pushbutton, the closing and breaking indicator plate, the energy storage indicator plate, and understand the parameters related to the electronic striker. Figure 19-2 shows the outline of the DW95 main switch.<\/p>\n<div style=\"text-align: center; margin: 20px 0;\">\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"aligncenter wp-image-15803\" title=\"DW95 universal automatic air circuit breaker shape and operation button marking\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9.png\" alt=\"DW95 universal automatic air circuit breaker shape and operation button marking\" width=\"432\" height=\"410\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9.png 892w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9-300x285.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9-768x730.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9-13x12.png 13w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/8ea270b897b179acc85bcfd19b5e29a9-600x570.png 600w\" sizes=\"(max-width: 432px) 100vw, 432px\" \/>Figure 19-2 DW95 Main Switch Outline Diagram<\/p>\n<\/div>\n<\/div>\n<div style=\"flex: 1; min-width: 320px;\">\n<p><strong>(2) Method of operation:<\/strong><\/p>\n<ul style=\"font-size: 14px; padding-left: 20px;\">\n<li>\u2460 Remove the three interrupters of the DW95 main switch and observe the structure of the main contacts and interrupters, as well as the structure of the auxiliary contacts.<\/li>\n<li>\u2461 Locate the positions of the three strikers in the main switch, including the position of the loss-of-voltage striker, the shunt striker, and the overcurrent striker. Observe the position of the striker shaft in relation to the three strikers and the manual release button.<\/li>\n<li>\u2462 Identify the closing mechanism of the main switch including the manual closing button, the closing solenoid, and the energy storage spring mechanism.<\/li>\n<li>\u2463 Observe the appearance of the IC striker to understand the parameters that can be set for the circuit striker, as shown in Figure 19-3.<\/li>\n<\/ul>\n<div style=\"text-align: center; margin-top: 20px;\">\n<p style=\"font-size: 13px; color: #666;\"><img decoding=\"async\" class=\"aligncenter wp-image-15804\" title=\"Circuit Breaker IC Electronic Tripper Parameter Adjustment Panel\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/63a064419cbff56a7bd61ffcdc5b5044.png\" alt=\"Circuit Breaker IC Electronic Tripper Parameter Adjustment Panel\" width=\"191\" height=\"224\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/63a064419cbff56a7bd61ffcdc5b5044.png 426w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/63a064419cbff56a7bd61ffcdc5b5044-256x300.png 256w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/63a064419cbff56a7bd61ffcdc5b5044-10x12.png 10w\" sizes=\"(max-width: 191px) 100vw, 191px\" \/>Figure 19-3 Integrated Circuit Striker Panel Diagram<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electronics &amp; Electrical Basic Skills Training | Automatic Air Circuit Breaker Disassembly &amp; Repair | Revision 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Circuit breaker, contactor, relay, fuse, electromagnetic brake disassembly and repair Section I: disassembly and repair of circuit breaker A. The composition of circuit breaker...<\/p>","protected":false},"author":1,"featured_media":15805,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15801","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15801"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15801\/revisions"}],"predecessor-version":[{"id":15806,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15801\/revisions\/15806"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15805"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15801"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15801"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}