{"id":15812,"date":"2026-01-07T10:27:38","date_gmt":"2026-01-07T02:27:38","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15812"},"modified":"2026-01-07T10:27:38","modified_gmt":"2026-01-07T02:27:38","slug":"jidianqidechangjianguzhangjixiulishiwushouce","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/jidianqidechangjianguzhangjixiulishiwushouce","title":{"rendered":"Manual of Common Faults and Repair Practices of Relays"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Manual of Common Faults and Repair Practices of Relays<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Thermal Relays - Inverse Power Relays - Time Relays<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Basic Concepts of Thermal Relays<\/h2>\n<div style=\"margin-top: 20px; padding: 0 10px;\">\n<p style=\"background: #fdf2f2; border-left: 5px solid #c0392b; padding: 15px; color: #721c24; font-weight: bold;\">\u26a0\ufe0f Core Points: Thermal relays are used for overload and phase loss protection of motors and cannot be used for short circuit protection.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">1. Components and principles of thermal relays<\/h3>\n<p style=\"text-indent: 2em;\">When the motor is running normally, the contacts do not operate. When the motor is overloaded, the heating element heats up more than the rated value, which increases the bimetal's deformation and bending degree, and pushes the contacts to break through the guide plate, and the control circuit is cut off and the AC contactor releases by cutting off the power to protect the motor.<\/p>\n<p style=\"text-indent: 2em;\">Thermal relays consist of two parts: the thermal element and the contacts. When used, the thermal element is connected in series in the main circuit and the normally closed contacts are connected in series in the control circuit. At least two heating elements are used.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">2. Symbols for thermal relays<\/h3>\n<div style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" class=\"aligncenter wp-image-15813\" title=\"Thermal Relay Electrical Control Schematic Symbol Description\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/e2d87300713ff421204d3deb35b57cb1.png\" alt=\"Thermal Relay Electrical Control Schematic Symbol Description\" width=\"403\" height=\"165\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/e2d87300713ff421204d3deb35b57cb1.png 718w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/e2d87300713ff421204d3deb35b57cb1-300x123.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/e2d87300713ff421204d3deb35b57cb1-18x7.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/e2d87300713ff421204d3deb35b57cb1-600x246.png 600w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><\/p>\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\">Figure 19-6 Symbols for Thermal Relays<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">II. Adjustment and reset of thermal relays<\/h2>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 30px; margin-top: 25px;\">\n<div style=\"background: #fcfcfc; border: 1px solid #ddd; padding: 25px; border-radius: 12px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">1. Adjustment of thermal relays<\/h4>\n<p style=\"font-size: 14px;\">Select the thermal relay according to the rated current of the motor, and the rated current of the thermal element is 1.1 to 1.25 times the rated current of the motor. The setting value of the thermal relay is the rated current of the motor. If the rated current of the motor is 18 A, turn the adjusting knob so that 1 8 and A can be aligned with the mark, as shown in Figure 19-7.<\/p>\n<div style=\"text-align: center; margin-top: 15px;\"><img decoding=\"async\" class=\"aligncenter wp-image-15814\" title=\"Schematic diagram for adjusting the rated current setting knob of thermal relay\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/07c8bd7727ffa591ebc76bc77afb3d8d.png\" alt=\"Schematic diagram for adjusting the rated current setting knob of thermal relay\" width=\"140\" height=\"110\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/07c8bd7727ffa591ebc76bc77afb3d8d.png 396w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/07c8bd7727ffa591ebc76bc77afb3d8d-300x236.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/07c8bd7727ffa591ebc76bc77afb3d8d-15x12.png 15w\" sizes=\"(max-width: 140px) 100vw, 140px\" \/><\/p>\n<p style=\"font-size: 12px; color: #666;\">Figure 19-7 Adjustment Schematic for Thermal Relay<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #fcfcfc; border: 1px solid #ddd; padding: 25px; border-radius: 12px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">2. Resetting of thermal relays<\/h4>\n<p style=\"font-size: 14px;\">There are two ways to reset the thermal relay after it has been actuated (human selectable): the contacts are reset automatically; the contacts must be reset by pressing the reset button.<\/p>\n<p style=\"font-size: 14px; border-top: 1px solid #eee; padding-top: 10px; margin-top: 10px;\"><strong>Example:<\/strong>The Model JR16B Thermal Relay can be selected for either automatic reset or manual reset. Its original set state is auto reset, to manually reset, the selector screw can be screwed out from the round hole next to it.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #ef9308; color: #fff; padding: 12px 25px; border-left: 10px solid #1f365c; border-radius: 4px; font-size: 22px;\">Third, the common faults of thermal relays and processing methods<\/h2>\n<div style=\"margin-top: 25px; overflow-x: auto;\">\n<table style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #ddd;\">\n<thead>\n<tr style=\"background: #f2f2f2;\">\n<th style=\"padding: 12px; border: 1px solid #ddd; width: 25%;\">fault phenomenon<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; width: 35%;\">Reason for failure<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; width: 40%;\">Treatment<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 12px; border: 1px solid #ddd; font-weight: bold;\">Inactivity or slowness of movement<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">The value of the setting current is too large, the thermal element is damaged or desoldered, the action mechanism is jammed, the bimetal plate is aged or deformed, and so on.<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Reasonable adjustment of the setting current value, replacement of damaged or desoldered thermal components, elimination of action mechanism jamming factors, replacement of aging or deformation of the bimetallic sheet.<\/td>\n<\/tr>\n<tr style=\"background: #fafafa;\">\n<td style=\"padding: 12px; border: 1px solid #ddd; font-weight: bold;\">malfunction<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">The set current value is too small, the ambient temperature is too high, the connecting wires are too thin, the starting time of the motor is too long, and the internal mechanism is loose.<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Reasonably adjust the setting current value, improve the ambient temperature, replace the connecting wires with suitable cross-sectional area, select the suitable thermal relay according to the motor condition, and fix the internal loose parts.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; border: 1px solid #ddd; font-weight: bold;\">Unstable movements<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Loose internal mechanism, bimetal bending, power supply voltage fluctuation, loose wiring screws, etc.<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Reinforce the internal mechanism, correct or replace the bimetal, stabilize the supply voltage, and tighten the wiring screws.<\/td>\n<\/tr>\n<tr style=\"background: #fafafa;\">\n<td style=\"padding: 12px; border: 1px solid #ddd; font-weight: bold;\">Main or control circuits not working<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Burnt thermal elements, untightened wiring screws, burnt contacts or loss of contact elasticity, improperly positioned adjustment screws, etc.<\/td>\n<td style=\"padding: 12px; border: 1px solid #ddd;\">Replace burnt thermal element, tighten wiring screws, repair or replace contacts and contacts, adjust screws to proper position.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Common faults and repairs of inverse power relays<\/h2>\n<div style=\"margin-top: 25px; padding: 0 10px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Functions of inverse power relays<\/h3>\n<p style=\"text-indent: 2em;\">Reverse power relay is one of the important protection components in ship power station, the main function is to sense the direction of current and automatically disconnect the alternator from the grid when reverse power occurs, so as to protect the safe operation of generator set and power grid. For example, NGJ-1 type reverse power relay is the latest generation of products in China, with beautiful appearance, complete functions, convenient adjustment, self-test function, light weight, small volume, only one-third of similar products in China, stable and reliable quality.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">(ii) Technical performance of inverse power relays<\/h3>\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px; font-size: 14px; margin-top: 15px;\">(1) The device operates normally when the grid voltage varies within \u00b110% of the rated voltage and the frequency varies within \u00b15% of the rated frequency;<br \/>\n(2) Inverse power relay power supply: 100 V (or 400 V), 50\/60 Hz, A and C phases, power consumption less than 2 V-A.<br \/>\n(3) When the inverse power of the parallel operation unit reaches 3%\uff5e15% of the rated frequency (continuously adjustable) with a delay of 3\uff5e10 s (continuously adjustable), the inverse power relay operates (a group of passive normally open becomes closed).<br \/>\n(4) Environmental conditions: ambient temperature of 0~55\u2103, relative humidity of 95%, shock and vibration, oil mist and salt spray during ship navigation.<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">(iii) Common failures of inverse power relays and how to deal with them<\/h3>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px; margin-top: 15px;\">\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">1. Inability to perceive the direction of the current:<\/strong><br \/>\nCause: Damaged or aged internal components.<br \/>\nTreatment: Check the internal components and replace damaged or aging components in a timely manner.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">2. Contact failure:<\/strong><br \/>\nCause: Loose, worn, fused or poor contact.<br \/>\nTREATMENT: Clean up oxidized layer, adjust pressure, and replace if necessary.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">3. Coil failure:<\/strong><br \/>\nCause: Broken wire, short circuit or damaged insulation.<br \/>\nTreatment: Check connectivity and insulation, repair or replace.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">4. Instability of parameters:<\/strong><br \/>\nCause: Loose riveting and poor bonding strength.<br \/>\nTreatment: Check the tooling and re-rivet.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">5. Failure of the electromagnetic system:<\/strong><br \/>\nCause: Poor contact of iron core, foreign matter or oil contamination.<br \/>\nTREATMENT: Remove foreign matter or oil and ensure flat contact.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">6. Insulator damage:<\/strong><br \/>\nCauses: bent pins, glass insulators falling out of place and cracking.<br \/>\nTreatment: Handle gently and replace damaged parts.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; font-size: 13px;\"><strong style=\"color: #c0392b;\">7. Operational instability:<\/strong><br \/>\nCause: Loose connection, electromagnetic interference or aging of relay.<br \/>\nTreatment: Reinforce connections and keep away from sources of interference.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">V. Common faults and repair of time relays<\/h2>\n<div style=\"margin-top: 25px; padding: 0 10px;\">\n<p><strong>1. Function of the time relay:<\/strong>An electrical device that delays response for a period of time after receiving an input signal.<br \/>\n<strong>2. Classification:<\/strong>According to the delay mode can be divided into two categories: power-on time-delay type and power-off time-delay type.<\/p>\n<div style=\"display: flex; gap: 20px; margin-top: 20px; align-items: flex-start;\">\n<div style=\"flex: 1; border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong>(1) Energized delay type<\/strong><\/p>\n<p style=\"font-size: 14px;\">When the coil is energized the contacts are delayed for a period of time before they actuate. When the coil is de-energized, the contacts reset immediately. The symbols are shown in Figure 19-8.<\/p>\n<div style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter wp-image-15815\" title=\"Difference in contact symbols between power-on delay and power-off delay type time relays6\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6.png\" alt=\"Difference in contact symbols between power-on delay and power-off delay type time relays\" width=\"358\" height=\"77\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6.png 832w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6-300x64.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6-768x164.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6-18x4.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f6e03eb3c6bfbfc56f26085aa3a2f4f6-600x128.png 600w\" sizes=\"(max-width: 358px) 100vw, 358px\" \/><\/p>\n<p style=\"font-size: 12px; color: #666; margin-top: 5px;\">Figure 19-8 Energized Delay Type Symbol<\/p>\n<\/div>\n<\/div>\n<div style=\"flex: 1; border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong>(2) Power failure delay type<\/strong><\/p>\n<p style=\"font-size: 14px;\">The contacts act immediately after the coil is energized and reset after a delayed period of time after the coil is de-energized. The symbols are shown in Figure 19-9.<\/p>\n<div style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter wp-image-15816\" title=\"Difference in contact symbols between power-on delay and power-off delay type time relays\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300.png\" alt=\"Difference in contact symbols between power-on delay and power-off delay type time relays0\" width=\"350\" height=\"73\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300.png 840w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300-300x63.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300-768x161.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300-18x4.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/264deebaa14e26e872c1665245fc6300-600x126.png 600w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/p>\n<p style=\"font-size: 12px; color: #666; margin-top: 5px;\">Figure 19-9 Power failure delay type symbol<\/p>\n<\/div>\n<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">3. Common failures of time relays and how to deal with them<\/h3>\n<div style=\"margin-top: 20px; border-left: 5px solid #1f365c; padding-left: 20px;\">\n<p><strong>(1) Inaccurate delay time:<\/strong><br \/>\nCauses: Poor sealing or leakage of the air bag, obstruction of the airway, damage to the non-magnetic gasket, malfunction of the clock mechanism, change in ambient temperature, etc.<br \/>\nTreatment: Check the sealing, replace the airbag or clean the airway; replace the damaged parts; troubleshoot the problem with several operations; adjust the setting value.<\/p>\n<p><strong>(2) Power failure:<\/strong><br \/>\nCauses: unstable voltage, short circuit or disconnection of the line, poor contact of the plug and socket.<br \/>\nTreatment: Use a regulated power supply; repair wiring; replace poor contact components.<\/p>\n<p><strong>(3) Contact failure:<\/strong><br \/>\nCause: Insufficient capacity\/pressure, surface oxidation. Treatment: Clean oxidized layer (oil polish file\/petrol); replace relay with higher capacity; adjust spring pressure.<\/p>\n<p><strong>(4) Failure of the electromagnetic system:<\/strong><br \/>\nCause: Coil insulation damage, short circuit grounding, core failure.<br \/>\nTREATMENT: Check insulation and connections; replace damaged coil; smooth core contact surfaces.<\/p>\n<p><strong>(5) Does not work when energized:<\/strong><br \/>\nCause: Poor power contact, voltage inconsistency, damaged internal electronic components. Treatment: Ensure good contact; check voltage; replace damaged components.<\/p>\n<p><strong>(6) Abnormal sounds:<\/strong><br \/>\nCause: Damaged mechanical structure, overheating of electronic components. Treatment: Replace mechanical parts; ensure good heat dissipation.<\/p>\n<p><strong>(7) The display panel is damaged:<\/strong><br \/>\nCause: Moisture, damaged electronic components. Treatment: Keep dry; replace damaged components.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electronics &amp; Electrical Basic Skills Training | Relay Troubleshooting &amp; Maintenance Manual | 2026 Revision<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Handbook of Common Relay Failures and Repair Practices Thermal Relays - Inverse Power Relays - Time Relays I. Basic Concepts of Thermal Relays \u26a0\ufe0f Nuclear...<\/p>","protected":false},"author":1,"featured_media":15817,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15812","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15812"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15812\/revisions"}],"predecessor-version":[{"id":15818,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15812\/revisions\/15818"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15817"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15812"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15812"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}