{"id":15819,"date":"2026-01-07T10:38:57","date_gmt":"2026-01-07T02:38:57","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15819"},"modified":"2026-01-07T10:43:20","modified_gmt":"2026-01-07T02:43:20","slug":"rongduanqidechangjianguzhangchaizhuangjixiulishiwushouce","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/rongduanqidechangjianguzhangchaizhuangjixiulishiwushouce","title":{"rendered":"Fuse common faults, disassembly and repair practice manuals"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">Fuse common faults, disassembly and repair practice manuals<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Short circuit and overload protection - Industrial\/Marine standards - Safe operation<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Structure and characteristics of the fuse<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 20px; margin-top: 25px;\">\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">1. Plug-in fuses<\/h4>\n<p style=\"font-size: 14px;\">Plug-in fuses are used to realize low voltage circuits for short circuit protection or overload protection of electrical equipment. The fuse is equipped with a fuse or fusible piece, the rated current of the fuse when in use must not exceed the rated current indicated on the porcelain, otherwise the arc generated when the fuse burns out is extremely strong and will burn out the fuse.<\/p>\n<\/div>\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">2. Screw-in fuses<\/h4>\n<p style=\"font-size: 14px;\">Spiral fuses are equipped with a fuse and quartz sand inside the fuse tube, which has a colored point at one end, and when the fuse is blown, the colored point jumps out, indicating that the fuse is broken.<\/p>\n<\/div>\n<div style=\"background: #f9f9f9; padding: 20px; border-radius: 8px; border: 1px solid #eee;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">3. Packed closed tube fuses<\/h4>\n<p style=\"font-size: 14px;\">By the fuse tube, fuse, indicator, packing and contact base and other components. Fuse with silver tape made of V-shaped narrow cross-section or mesh form, with rapidity, can be used as a semiconductor rectifier components of the short-circuit protection and overload protection.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Second, the selection of fuses<\/h2>\n<div style=\"margin-top: 25px; padding: 0 10px;\">\n<p style=\"text-indent: 2em;\">Fuses are mainly selected according to the load and the size of the circuit short-circuit current. For the protection of lighting lines or motors with small capacity, semi-closed tube fuses or closed tube fuses without packing can be used; for circuits with considerable short-circuit currents or places with flammable gases, closed tube fuses with packing should be used; for the protection of thyristors and silicon components, fast fuses should be used.<\/p>\n<div style=\"background: #eef2f7; padding: 25px; border-radius: 12px; margin: 25px 0;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">Core Computational Principles:<\/h4>\n<p style=\"font-size: 14px;\">Due to a variety of electrical equipment have a certain overload capacity, when the overload capacity is weak, can be allowed to run for a longer period of time, and more than a certain overload multiplier, the melt is required to fuse within a certain period of time. There are also some equipment start-up current is very large, such as three-phase asynchronous motor start-up current is 5 to 7 times the rated current, therefore, the choice of melt must be considered when the characteristics of the equipment.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px; margin-top: 15px;\">\n<div style=\"background: #fff; padding: 15px; border-radius: 6px; border-left: 5px solid #1f365c;\"><strong>(1) Lighting branch circuits:<\/strong><br \/>\nRated fuse current \u2265 sum of the operating currents of all lamps on the branch circuit<\/div>\n<div style=\"background: #fff; padding: 15px; border-radius: 6px; border-left: 5px solid #1f365c;\"><strong>(2) Single direct start motor:<\/strong><br \/>\nMelt rated current \u2265 (1.5~2.5) \u00d7 motor rated current<\/div>\n<div style=\"background: #fff; padding: 15px; border-radius: 6px; border-left: 5px solid #1f365c;\"><strong>(3) The low voltage side of the distribution transformer:<\/strong><br \/>\nRated current of the fuse = (1~1.2) \u00d7 rated current of the low voltage side of the transformer<\/div>\n<\/div>\n<\/div>\n<p style=\"text-indent: 2em; color: #c0392b; font-weight: bold;\">The fuse should fuse reliably under the action of short-circuit current. If it is selected on the large side, it will not fuse in time; if it is selected on the small side, it will fuse under normal load.<\/p>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Third, the fuse when using the precautions<\/h2>\n<div style=\"margin-top: 20px; background: #fff8e6; padding: 25px; border-radius: 10px; border: 1px solid #ffeeba;\">\n<ul style=\"padding-left: 20px; font-size: 14px; line-height: 1.8;\">\n<li>(1) When replacing a fuse, replace it with one of the same type, material, size, and current rating as specified.<\/li>\n<li>(2) The rated voltage of the fuse shall not be less than the rated voltage of the line.<\/li>\n<li>(3) Fuses with appropriate breaking capacity shall be selected to cope with the maximum possible short-circuit current.<\/li>\n<li>(4) <strong>Cooperation at all levels:<\/strong>It is usually required that the former melt is 2 to 3 times larger than the latter melt to avoid transgressive action.<\/li>\n<li>(5) A fuse cannot be loaded for continued use with a single fuse lapped over the ends of the fused tube.<\/li>\n<li>(6) Fuses can only do the short circuit protection of the main circuit of the motor, can not do overload protection.<\/li>\n<li>(7) In grounded lines, three-phase four-wire neutral lines, DC motor excitation circuits<strong>impermissible<\/strong>Tap into the fuse.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #ef9308; color: #fff; padding: 12px 25px; border-left: 10px solid #1f365c; border-radius: 4px; font-size: 22px;\">Fourth, the common failure of the fuse<\/h2>\n<div style=\"margin-top: 25px; display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 15px;\">\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong style=\"color: #c0392b;\">1. Fuse blowing<\/strong><br \/>\n<span style=\"font-size: 13px;\">Cause: circuit overload, short circuit, improper selection or aging. Phenomenon: Circuit breaks, fuses are disconnected or burned black.<\/span><\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong style=\"color: #c0392b;\">2. Poor contact<\/strong><br \/>\n<span style=\"font-size: 13px;\">Cause: Oxidized, loose and dirty base contacts. Phenomenon: Heat, circuit on and off, arc.<\/span><\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong style=\"color: #c0392b;\">3. Cosmetic damage<\/strong><br \/>\n<span style=\"font-size: 13px;\">Cause: Mechanical impact, high temperature ablation. Phenomenon: Cracked, deformed or carbonized shell.<\/span><\/div>\n<div style=\"border: 1px solid #ddd; padding: 15px; border-radius: 8px;\"><strong style=\"color: #c0392b;\">4. Malfunction or failure to fuse<\/strong><br \/>\n<span style=\"font-size: 13px;\">Cause: Poor quality, current mismatch. Phenomenon: Circuit abnormal but not disconnected, vulnerable equipment.<\/span><\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">V. Fuse disassembly steps<\/h2>\n<div style=\"margin-top: 25px; background: #f0f4f8; padding: 30px; border-radius: 12px;\">\n<ol style=\"padding-left: 20px; line-height: 2;\">\n<li><strong>(1) Disconnect and test the power:<\/strong>Turn off the power switch and use a power test pen to confirm that the circuit is free of electricity.<\/li>\n<li><strong>(2) Remove fuses:<\/strong>Use an insulated screwdriver or special tool to loosen the fixing screws. Pull out vertically (insertion type) or unscrew (screw type).<\/li>\n<li><strong>(3) Check the base:<\/strong>Observe contacts for oxidation, ablation or looseness and clean or replace as necessary.<\/li>\n<li><strong>(4) Select matching fuses:<\/strong>Make sure the old and new specifications (current and voltage) are the same.<\/li>\n<li><strong>(5) Fixed fuses:<\/strong>Make sure the contact is tight and tighten the screws to avoid false connections.<\/li>\n<li><strong>(6) Energized test:<\/strong>Close the gate and observe if it is normal and there is no abnormal heat or spark.<\/li>\n<\/ol>\n<\/div>\n<p>&nbsp;<\/p>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">VI. Repair and maintenance of fuses<\/h2>\n<div style=\"margin-top: 25px; display: grid; grid-template-columns: 1fr 1fr; gap: 20px;\">\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">1. Handling after fusing<\/h4>\n<p style=\"font-size: 14px;\">direct replacement of the fuse with a new one.<strong>Prohibition of substitution of copper and iron wires<\/strong>The following is an example of how to replace an overload or short-circuit fault. Always troubleshoot an overload or short circuit before replacing.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">2. Contact cleaning and repair<\/h4>\n<p style=\"font-size: 14px;\">Polish the oxidized contacts with fine sandpaper. If severely deformed or burnt, the entire base must be replaced.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">3. Fuse housing repair<\/h4>\n<p style=\"font-size: 14px;\">Minor damage can be temporarily repaired with insulating tape. Severe carbonization or cracking must be scrapped and replaced.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #eee; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">4. Melt replacement<\/h4>\n<p style=\"font-size: 14px;\">Only for replaceable melts such as knife type. Install the new melt according to the original specifications, making sure that the connection is secure.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #c0392b; color: #fff; padding: 12px 25px; border-left: 10px solid #1f365c; border-radius: 4px; font-size: 22px;\">VII. Security considerations<\/h2>\n<div style=\"margin-top: 25px; border: 2px solid #c0392b; padding: 25px; border-radius: 12px;\">\n<ul style=\"margin: 0; padding-left: 20px; font-weight: bold; line-height: 2;\">\n<li>(1) Power-off operation: power must be disconnected before disassembly or repair to avoid electric shock or arc burns.<\/li>\n<li>(2) Protective measures: wear insulated gloves and goggles, use insulated tools.<\/li>\n<li>(3) Prohibition of electrically charged replacement: Do not directly electrically replace the fuse after it has blown.<\/li>\n<li>(4) Environmental requirements: Avoid operation in humid and flammable environments.<\/li>\n<li>(5) Periodic inspection: clean dust, tighten screws.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Marine Electrical and Electronic Basic Skills Training | Fuse Maintenance and Repair Specifications | 2026 Revision<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Fuse Common Faults, Disassembly and Repair Practice Manual Short Circuit and Overload Protection - Industrial\/Marine Standards - Safe Operation I. Fuse Structure and Special ...<\/p>","protected":false},"author":1,"featured_media":15827,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15819","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15819"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15819\/revisions"}],"predecessor-version":[{"id":15820,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15819\/revisions\/15820"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15827"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15819"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15819"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}