{"id":15828,"date":"2026-01-07T10:48:00","date_gmt":"2026-01-07T02:48:00","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15828"},"modified":"2026-01-07T10:48:00","modified_gmt":"2026-01-07T02:48:00","slug":"tongyongbianpinqidewaibujiexianyuyingyongguifan","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/en\/project\/tongyongbianpinqidewaibujiexianyuyingyongguifan","title":{"rendered":"External wiring and application specifications for general-purpose inverters"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 32px; margin-bottom: 10px; font-weight: bold;\">External wiring and application specifications for general-purpose inverters<\/h1>\n<div style=\"display: inline-block; background: #1f365c; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px;\">Industrial automation - Speed control - Energy saving technology<\/div>\n<\/div>\n<section style=\"margin-bottom: 40px;\">\n<p style=\"text-indent: 2em; background: #f9f9f9; padding: 20px; border-radius: 4px; border-left: 5px solid #1f365c;\">Variable Frequency Drive (VFD) is a type of power electronic device mainly used to regulate the speed and torque of AC motors. By changing the frequency of the power supply to the motor, the VFD can precisely control the speed of the motor to meet different process requirements. The main functions of VFDs include: speed control, energy saving, improving process control accuracy, protecting motors and equipment, adapting to different load requirements, and improving power grid quality.<\/p>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. The main role of the frequency converter<\/h2>\n<div style=\"margin-top: 25px; display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 20px;\">\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">1. Speed control:<\/strong>Allows the user to adjust the running speed of the motor according to the actual need instead of fixing it at one speed.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">2. Energy efficiency:<\/strong>Energy consumption is reduced during off-peak hours by regulating the speed. Power consumption is proportional to the cube of the speed.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">3. Improvement of process control accuracy:<\/strong>Provides smooth start\/stop and precise speed\/torque control to improve production quality.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">4. Protection of motors and equipment:<\/strong>Soft start\/stop reduces the impact and provides various protections such as over-current, over-voltage and overload.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">5. Adaptation to different loads:<\/strong>Enables the motor to operate at the optimum efficiency point, suitable for constant or variable torque loads.<\/div>\n<div style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px;\"><strong style=\"color: #1f365c;\">6. Improvement of the quality of the power grid:<\/strong>Harmonic distortion of the input current is reduced by filters or active front-end techniques.<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Second, the choice of frequency converter points<\/h2>\n<div style=\"margin-top: 25px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Load characteristics and motor parameters<\/h3>\n<p style=\"font-size: 14px;\">\u25cf <strong>Load Type:<\/strong>Constant torque (e.g. cranes, select overload capacity); variable torque (e.g. fans and pumps, select energy-saving).<br \/>\n\u25cf <strong>Motor parameters:<\/strong>Match power, voltage, current, poles and frequency range.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">(ii) Inverter performance parameters<\/h3>\n<p style=\"font-size: 14px;\">\u25cf <strong>Power Capacity:<\/strong>Not less than the motor power, heavy load leave 20% ~ 30% margin.<br \/>\n\u25cf <strong>Control Method:<\/strong>V\/F control (low cost, simple speed regulation); vector control (high precision torque\/speed control).<br \/>\n\u25cf <strong>Overload capacity:<\/strong>Generally support 120% to 150% for 1min.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 30px;\">(iii) Environmental adaptation and functional needs<\/h3>\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px;\">\n<p style=\"font-size: 14px; margin: 0;\"><strong>Installation environment:<\/strong>Temperature (-10~40\u2103), Humidity (&lt;90%), Protection class (IP).<br \/>\n<strong>EMC:<\/strong>Add reactors and filters to avoid sharing power with PLC.<br \/>\n<strong>Craft Functions:<\/strong>PID regulation, multiband speed, jump frequency, braking function (braking resistor).<br \/>\n<strong>Interfaces and Security:<\/strong>Communication (Modbus\/Profinet), safety functions (STO).<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">III. Maintenance and repair priorities<\/h2>\n<ul style=\"margin-top: 25px; padding-left: 20px; line-height: 2;\">\n<li>Check the operating environment (temperature and humidity) and open the cover to assist in heat dissipation at high temperatures.<\/li>\n<li>Clean the dust and ensure that the surrounding area is free of odors and flammable and explosive gases.<\/li>\n<li>Check the body for abnormal vibration, noise and odor, and confirm that the terminals are tight.<\/li>\n<li>Check the smoothness of motor operation and temperature.<\/li>\n<li>Monitor input voltage, current and output current parameters.<\/li>\n<\/ul>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">Typical wiring of inverter<\/h2>\n<div style=\"margin-top: 25px;\">\n<p style=\"text-indent: 2em;\">There are many conventional inverter manufacturers (ABB, Siemens, Schneider, etc.). This section is organized in<strong>Siemens SINAMICS V20 three-phase 400 V frequency converter<\/strong>As an example, explain.<\/p>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 25px; border-radius: 12px; margin-top: 20px;\">\n<p style=\"font-size: 15px;\"><strong>Typical wiring instructions (refer to Figure 20-1):<\/strong><\/p>\n<p style=\"font-size: 14px;\">Power supply is connected to the power terminals through fuses, contactors, incoming reactors, filters <strong>L1, L2, L3<\/strong>. Motor terminals <strong>U, V, W<\/strong> Connect to the motor through the output reactor. All equipment PE terminals must be earthed. The braking terminals are used for energy braking through the connection of a braking unit and a braking resistor. Remote operation is possible via the BOP interface module or by connecting the intelligent connection module for quick commissioning.<\/p>\n<\/div>\n<div style=\"text-align: center; margin: 30px 0;\">\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15829 aligncenter\" title=\"19bbc670084a305b23ec6afd27d73cd2\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2.png\" alt=\"19bbc670084a305b23ec6afd27d73cd2\" width=\"504\" height=\"571\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2.png 862w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2-265x300.png 265w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2-768x870.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2-11x12.png 11w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/19bbc670084a305b23ec6afd27d73cd2-600x679.png 600w\" sizes=\"(max-width: 504px) 100vw, 504px\" \/>Figure 20-1 Typical wiring of an inverter<\/p>\n<\/div>\n<div style=\"text-align: center; margin: 30px 0;\">\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><img decoding=\"async\" class=\"wp-image-15830 aligncenter\" title=\"520d238ef9348cac8bcc86f3293d102a\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a.png\" alt=\"520d238ef9348cac8bcc86f3293d102a\" width=\"471\" height=\"530\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a.png 892w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a-267x300.png 267w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a-768x864.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a-11x12.png 11w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/520d238ef9348cac8bcc86f3293d102a-600x675.png 600w\" sizes=\"(max-width: 471px) 100vw, 471px\" \/>Figure 20-2 Main and Control Circuit Wiring Diagram for the SINAMICS V20<\/p>\n<\/div>\n<div style=\"background: #fff8e6; padding: 20px; border: 1px solid #ffeeba; border-radius: 8px; margin-top: 30px;\">\n<p style=\"font-size: 14px; margin: 0;\"><strong>Points to note:<\/strong><br \/>\n1. Shielded cable length limitation: under the same conditions, the length of shielded cable used is less than that of unshielded cable.<br \/>\n2. 87 Hz technology: When a 400V inverter is connected to a 230V\/400V motor with an operating frequency of 87 Hz, the motor should be selected with<strong>triangular connection<\/strong>\u3002<\/p>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Hands-on Automation Control Training | Frequency Converter Applications | Revision 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>External wiring and application specifications for general-purpose frequency converters Industrial Automation - Speed Control - Energy Saving Technology Variable Freque...<\/p>","protected":false},"author":1,"featured_media":15831,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15828","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15828","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/comments?post=15828"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15828\/revisions"}],"predecessor-version":[{"id":15832,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio\/15828\/revisions\/15832"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media\/15831"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/media?parent=15828"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_category?post=15828"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/en\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15828"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}