{"id":15370,"date":"2026-01-03T21:30:41","date_gmt":"2026-01-03T13:30:41","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15370"},"modified":"2026-01-06T11:00:42","modified_gmt":"2026-01-06T03:00:42","slug":"tongbubiaofashoudongzhuntongbubingche-fuzaizhuanyijifenpeishoudongjieliecaozuo","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/es\/project\/tongbubiaofashoudongzhuntongbubingche-fuzaizhuanyijifenpeishoudongjieliecaozuo","title":{"rendered":"Fusi\u00f3n manual casi sincr\u00f3nica, transferencia y distribuci\u00f3n de la carga, operaci\u00f3n manual de eliminaci\u00f3n de la lista por el m\u00e9todo de tabla sincr\u00f3nica"},"content":{"rendered":"<p style=\"text-align: center;\"><strong><b>M\u00e9todo de sincronizaci\u00f3n con reloj: sincronizaci\u00f3n manual y conexi\u00f3n en paralelo,<\/b><\/strong>\u00a0<strong><b>Transferencia y distribuci\u00f3n de carga, operaciones manuales de desconexi\u00f3n<\/b><\/strong><\/p>\n<p><strong><b>I. Sincronizaci\u00f3n de generadores s\u00edncronos<\/b><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>1. Comprobaci\u00f3n del estado de la red antes de la conexi\u00f3n (suponiendo que el generador n\u00ba 1 est\u00e1 funcionando en la red en ese momento y los generadores n\u00ba 2 y 3 est\u00e1n en espera).<\/p>\n<p>(1) El modo de funcionamiento de la central el\u00e9ctrica se encuentra en estado normal, es decir, el selector de modo est\u00e1 en la posici\u00f3n \u201cMANU\u201d, tal y como se muestra en la figura 2-1.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15372\" title=\"4eec267b5b68d20f8b6de0ede8770822-1\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1.png\" alt=\"4eec267b5b68d20f8b6de0ede8770822-1\" width=\"843\" height=\"292\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1.png 843w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1-300x104.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1-768x266.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1-18x6.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4eec267b5b68d20f8b6de0ede8770822-1-600x208.png 600w\" sizes=\"auto, (max-width: 843px) 100vw, 843px\" \/><\/p>\n<p style=\"text-align: center;\"><strong><b>Figura 2-1<\/b><\/strong>\u00a0<strong><b>Selecci\u00f3n del modo de funcionamiento<\/b><\/strong><\/p>\n<p>(2) Compruebe que la tensi\u00f3n y la frecuencia del generador n.\u00ba 1 sean normales, tal y como se muestra en la figura 2-2. Si la frecuencia o la tensi\u00f3n presentan desviaciones, realice los ajustes correspondientes.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15373\" title=\"c15d0327f38ffba62d397fc91903d6cb\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c15d0327f38ffba62d397fc91903d6cb.png\" alt=\"c15d0327f38ffba62d397fc91903d6cb\" width=\"762\" height=\"206\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c15d0327f38ffba62d397fc91903d6cb.png 762w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c15d0327f38ffba62d397fc91903d6cb-300x81.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c15d0327f38ffba62d397fc91903d6cb-18x5.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c15d0327f38ffba62d397fc91903d6cb-600x162.png 600w\" sizes=\"auto, (max-width: 762px) 100vw, 762px\" \/><\/p>\n<p style=\"text-align: center;\"><strong><b>Figura 2-2<\/b><\/strong>\u00a0<strong><b>Instrumentaci\u00f3n el\u00e9ctrica<\/b><\/strong><\/p>\n<p>(3) Observar la potencia del generador funcionando en la red, si es superior a 80% de su potencia aut\u00f3noma, se debe poner en marcha la unidad de reserva.<\/p>\n<p><strong><b>2.<\/b><\/strong><strong><b>Puesta en marcha de la unidad de reserva<\/b><\/strong><\/p>\n<p>(1) Teniendo en cuenta el historial de uso y el estado mec\u00e1nico y el\u00e9ctrico de los generadores n.\u00ba 2 y n.\u00ba 3, se seleccionar\u00e1 uno de ellos como unidad de reserva (supongamos que en este caso se elige el generador n.\u00ba 2).<\/p>\n<p>(2) Comprobar si el generador n.\u00ba 2 cumple las condiciones de arranque: agua de refrigeraci\u00f3n, aceite lubricante, combustible y suministro de aire de arranque. Comprobar que el selector \u201cLOCAL\/REMOTE\u201d del panel de control junto a la m\u00e1quina se encuentre en la posici\u00f3n \u201cREMOTE\u201d. Comprobar que el indicador \u201cREADY FOR START\u201d correspondiente a dicha unidad en el cuadro de distribuci\u00f3n principal permanezca encendido.<\/p>\n<p>(3) Cuando sea necesario realizar una conexi\u00f3n manual a la red, pulse el bot\u00f3n \u201cENGINE START\u201d del generador n.\u00ba 2, tal y como se muestra en la figura 2-3, para poner en marcha el grupo electr\u00f3geno de reserva; espere a que el grupo alcance una velocidad cercana a la nominal y funcione de forma estable durante unos minutos. Observe si la tensi\u00f3n y la frecuencia del generador que se va a conectar son normales. Por lo general, no es necesario ajustar la tensi\u00f3n, ya que cuenta con un regulador autom\u00e1tico de tensi\u00f3n (AVR). Se puede ajustar manualmente la velocidad del generador que se va a conectar, de modo que su frecuencia sea igual o ligeramente superior a la de la red el\u00e9ctrica.<\/p>\n<div id=\"attachment_15374\" style=\"width: 596px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15374\" class=\"wp-image-15374 size-full\" title=\"c3ee398f70672cbff1413361fdd08d56\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c3ee398f70672cbff1413361fdd08d56.png\" alt=\"Figura 2-3: Control de arranque y parada del generador\" width=\"586\" height=\"510\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c3ee398f70672cbff1413361fdd08d56.png 586w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c3ee398f70672cbff1413361fdd08d56-300x261.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c3ee398f70672cbff1413361fdd08d56-14x12.png 14w\" sizes=\"auto, (max-width: 586px) 100vw, 586px\" \/><p id=\"caption-attachment-15374\" class=\"wp-caption-text\">Figura 2-3: Control de arranque y parada del generador<\/p><\/div>\n<p><strong><b>3.<\/b><\/strong><strong><b>\u5e76<\/b><\/strong>\u00a0<strong><b>\u8f66<\/b><\/strong>\u00a0<strong><b>(<\/b><\/strong>\u00a0<strong><b>\u4f7f<\/b><\/strong>\u00a0<strong><b>\u7528<\/b><\/strong>\u00a0<strong><b>\u540c<\/b><\/strong>\u00a0<strong><b>\u6b65<\/b><\/strong>\u00a0<strong><b>\u8868<\/b><\/strong>\u00a0<strong><b>)<\/b><\/strong><\/p>\n<p>(1) Encender el sincrono y seleccionar el generador que se va a conectar a la red, tal y como se muestra en la figura 2-4, para comprobar mediante el sincrono la magnitud, la direcci\u00f3n y la diferencia de fase de la diferencia de frecuencia entre la red el\u00e9ctrica y el generador que se va a conectar. La direcci\u00f3n de giro de la aguja del sincrono depende de la direcci\u00f3n de la diferencia de frecuencia: el giro en sentido horario indica que la frecuencia del generador que se va a conectar es superior a la de la red el\u00e9ctrica. La velocidad de rotaci\u00f3n de la aguja del sincrono indica la magnitud de la diferencia de frecuencia; el periodo de rotaci\u00f3n es inversamente proporcional a dicha diferencia. Por ejemplo, cuando se requiere una diferencia de frecuencia de 0,25 Hz, el periodo de rotaci\u00f3n debe ser de 4 s. La diferencia de fase var\u00eda constantemente; la posici\u00f3n de la aguja del sincrono indica la diferencia de fase instant\u00e1nea; por ejemplo, la posici\u00f3n de las 11 en punto representa una diferencia de fase de 30\u00b0, mientras que la posici\u00f3n de las 6 en punto representa una fase inversa (diferencia de fase de 180\u00b0).<\/p>\n<div id=\"attachment_15375\" style=\"width: 960px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15375\" class=\"wp-image-15375 size-full\" title=\"18fb2b3c8f33d62a81126ab1e0e9e058\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058.png\" alt=\"Figura 2-4: Selecci\u00f3n de relojes de sincronizaci\u00f3n\" width=\"950\" height=\"360\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058.png 950w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058-300x114.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058-768x291.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058-18x7.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/18fb2b3c8f33d62a81126ab1e0e9e058-600x227.png 600w\" sizes=\"auto, (max-width: 950px) 100vw, 950px\" \/><p id=\"caption-attachment-15375\" class=\"wp-caption-text\">Figura 2-4: Selecci\u00f3n de relojes de sincronizaci\u00f3n<\/p><\/div>\n<p>(2) Para la conexi\u00f3n a la red, es necesario que la frecuencia del generador a conectar sea ligeramente superior (entre 0,2 y 0,33 Hz); por lo tanto, la aguja del sincr\u00f3nmetro debe ajustarse de modo que d\u00e9 una vuelta completa en sentido horario en un intervalo de 3 a 5 segundos. Si la conexi\u00f3n se realiza con un giro en sentido antihorario (cuando la frecuencia del generador a conectar es inferior a la de la red), el generador a conectar...<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Evaluaci\u00f3n pr\u00e1ctica de t\u00e9cnico en electr\u00f3nica y electricidad I<\/p>\n<p>Funcionamiento y mantenimiento de las centrales el\u00e9ctricas de los buques; gesti\u00f3n y procesos el\u00e9ctricos y electr\u00f3nicos de los buques<\/p>\n<p>Tras la conexi\u00f3n a la red el\u00e9ctrica, se produce una potencia inversa que provoca el fallo de la sincronizaci\u00f3n. Si la diferencia de frecuencia es demasiado grande (el periodo de rotaci\u00f3n de la aguja es inferior a 2 s y la diferencia de frecuencia es superior a 0,5 Hz), la energ\u00eda cin\u00e9tica residual de la unidad con mayor velocidad de giro tras el cierre del interruptor es muy elevada, y el par de sincronizaci\u00f3n generado por ambas unidades no es suficiente para llevarlas a la sincronizaci\u00f3n; el resultado ser\u00e1 una p\u00e9rdida de sincronizaci\u00f3n que provocar\u00e1 un fuerte impacto y, por consiguiente, un disparo del interruptor y un corte del suministro el\u00e9ctrico.<\/p>\n<p>(3) Para la conexi\u00f3n en paralelo, se requiere que la diferencia de fase no supere los 15\u00b0 y que el punto de fase coincida a las 12 en punto. Sin embargo, dado que existe un cierto retraso entre el momento en que se pulsa el bot\u00f3n de cierre y el cierre efectivo del interruptor principal, es necesario adelantar ligeramente el cierre; por ello, normalmente se fija el momento del cierre a las 11 en punto. La sincronizaci\u00f3n exige una precisi\u00f3n elevada en cuanto a la diferencia de fase; una diferencia de fase demasiado grande provocar\u00eda una corriente de impacto excesiva, lo que no solo har\u00eda que fallara el cierre del generador que se va a sincronizar, sino que tambi\u00e9n provocar\u00eda el disparo de la unidad de alimentaci\u00f3n, causando un corte de suministro el\u00e9ctrico en todo el buque. Queda terminantemente prohibido realizar el cierre con una diferencia de fase de aproximadamente 180\u00b0.<\/p>\n<p>(4) Una vez realizada con \u00e9xito la conexi\u00f3n, tal y como se muestra en la figura 2-5, se debe desconectar inmediatamente el medidor de sincronizaci\u00f3n. Dado que el medidor de sincronizaci\u00f3n est\u00e1 dise\u00f1ado para un funcionamiento de corta duraci\u00f3n, su tiempo de funcionamiento no debe superar los 15 minutos.<\/p>\n<p>(5) La carga debe transferirse a tiempo tras una fusi\u00f3n satisfactoria.<\/p>\n<div id=\"attachment_15376\" style=\"width: 576px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15376\" class=\"wp-image-15376 size-full\" title=\"bbfcfc5278c057a2096afb677ab4b3b1\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/bbfcfc5278c057a2096afb677ab4b3b1.png\" alt=\"Figura 2-5: Funcionamiento en paralelo de los generadores\" width=\"566\" height=\"508\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/bbfcfc5278c057a2096afb677ab4b3b1.png 566w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/bbfcfc5278c057a2096afb677ab4b3b1-300x269.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/bbfcfc5278c057a2096afb677ab4b3b1-13x12.png 13w\" sizes=\"auto, (max-width: 566px) 100vw, 566px\" \/><p id=\"caption-attachment-15376\" class=\"wp-caption-text\">Figura 2-5: Funcionamiento en paralelo de los generadores<\/p><\/div>\n<p><strong><b>II. Transferencia de carga y distribuci\u00f3n de unidades paralelas<\/b><\/strong><\/p>\n<p>(1) Justo despu\u00e9s de la conexi\u00f3n en paralelo, se ajustan la frecuencia y la carga, tal y como se muestra en la figura 2-6. Como se puede observar en el medidor de potencia, la aguja del medidor del generador reci\u00e9n conectado se encuentra cerca de cero, lo que indica que a\u00fan no soporta carga. Mediante el ajuste de los mandos de control de velocidad de ambos generadores, se acelera el generador reci\u00e9n conectado y se reduce la velocidad del generador que ya estaba en la red, de modo que, manteniendo la frecuencia del busbar en su valor nominal, ambas unidades asuman la carga de forma equilibrada.<\/p>\n<div id=\"attachment_15377\" style=\"width: 1074px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15377\" class=\"wp-image-15377 size-full\" title=\"950b70c75dcbf34bdc802277841f6221\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221.png\" alt=\"Figura 2-6: Regulaci\u00f3n de la velocidad de giro\" width=\"1064\" height=\"364\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221.png 1064w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221-300x103.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221-1024x350.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221-768x263.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221-18x6.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/950b70c75dcbf34bdc802277841f6221-600x205.png 600w\" sizes=\"auto, (max-width: 1064px) 100vw, 1064px\" \/><p id=\"caption-attachment-15377\" class=\"wp-caption-text\">Figura 2-6: Regulaci\u00f3n de la velocidad de giro<\/p><\/div>\n<p><strong><b>III. Conocimientos relacionados<\/b><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>1. \u00bfQu\u00e9 condiciones hay que cumplir para incorporarse al tr\u00e1fico?<\/p>\n<p>(1) El valor eficaz de la tensi\u00f3n U\u2082 del generador que se va a conectar es igual al valor eficaz de la tensi\u00f3n U\u2081 del generador en funcionamiento, es decir, U\u2082 = U\u2081.<\/p>\n<p>(2) La frecuencia f\u2082 del generador que se va a conectar debe ser igual a la frecuencia f del generador en funcionamiento, es decir, f\u2082 = f\u2081.<\/p>\n<p>(3) Cuando la fase \u03b4\u2082 de la tensi\u00f3n del generador en espera coincida con la fase \u03b4\u2081 de la tensi\u00f3n del generador en funcionamiento, es decir, cuando \u03b4\u2082 = 81.<\/p>\n<p>(4) Esperar a que el orden de las fases de la tensi\u00f3n del generador en conexi\u00f3n sea el mismo que el del generador en funcionamiento (el orden de las fases de la tensi\u00f3n real del generador ya se ha determinado durante la instalaci\u00f3n y la puesta en marcha, por lo que no es necesario determinarlo en este momento).<\/p>\n<p>Si los par\u00e1metros difieren considerablemente, se producir\u00e1 una corriente de impacto muy elevada. Si la corriente de impacto es demasiado elevada, se producir\u00e1 un fallo en la sincronizaci\u00f3n; en casos graves, esto podr\u00eda provocar un corte de suministro el\u00e9ctrico en todo el buque e incluso causar da\u00f1os en los grupos electr\u00f3genos.<\/p>\n<p><strong><b>2. \u00bfQu\u00e9 es la sincronizaci\u00f3n por arrastre?<\/b><\/strong><\/p>\n<p>Al sincronizar un generador, si en el instante del cierre de un interruptor no se cumple alguna de las condiciones de sincronizaci\u00f3n, se producir\u00e1 una corriente de impacto entre los grupos generadores.<\/p>\n<p>(1) La componente reactiva de la corriente de impacto act\u00faa como equilibrador de tensi\u00f3n.<\/p>\n<p>(2) La componente activa de la corriente de impacto desempe\u00f1a una funci\u00f3n de sincronizaci\u00f3n. El par de sincronizaci\u00f3n correspondiente a la potencia de sincronizaci\u00f3n es, en el caso de un generador adelantado, un par de resistencia que reduce la velocidad de giro; en el caso de un generador atrasado, es un par de accionamiento que aumenta la velocidad de giro, lo que finalmente lleva a ambos generadores a un funcionamiento sincr\u00f3nico en la misma fase. Este proceso se denomina proceso de sincronizaci\u00f3n por arrastre.<\/p>\n<p><strong><b>3.<\/b><\/strong><strong><b>\u00bfC\u00f3mo se utiliza la t\u00e9cnica de las luces para circular en paralelo?<\/b><\/strong><\/p>\n<p>(1) M\u00e9todo de la luz intensa y tenue<\/p>\n<p>El principio del m\u00e9todo de variaci\u00f3n de intensidad luminosa se muestra en la figura 2-7. Supongamos que, en este momento, la amplitud de la tensi\u00f3n del generador es la misma (algo que, en la pr\u00e1ctica, resulta bastante f\u00e1cil de conseguir); cuando la fase de la tensi\u00f3n del generador que se va a conectar coincide con la de la red el\u00e9ctrica, la diferencia de tensi\u00f3n es, en teor\u00eda, 0, y la luz se apaga; cuando las fases de ambas tensiones est\u00e1n en sentido contrario, la diferencia de tensi\u00f3n es m\u00e1xima y la luz brilla con mayor intensidad. Cuando la diferencia de fase var\u00eda entre 0 y 180\u00b0, el brillo de la luz cambia entre apagada, m\u00e1xima intensidad y parpadeo tenue. La velocidad del parpadeo indica la magnitud de la diferencia de frecuencia, mientras que el apagado indica la coincidencia del \u00e1ngulo de fase (es decir, que las fases coinciden); en ese momento se puede realizar la conexi\u00f3n.<\/p>\n<div id=\"attachment_15378\" style=\"width: 1184px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15378\" class=\"wp-image-15378 size-full\" title=\"1f2ccc8f85c504101d4fe45c4843b564\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564.png\" alt=\"Figura 2-7: Principio del m\u00e9todo de la luz clara y oscura\" width=\"1174\" height=\"596\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564.png 1174w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564-300x152.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564-1024x520.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564-768x390.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564-18x9.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/1f2ccc8f85c504101d4fe45c4843b564-600x305.png 600w\" sizes=\"auto, (max-width: 1174px) 100vw, 1174px\" \/><p id=\"caption-attachment-15378\" class=\"wp-caption-text\">Figura 2-7: Principio del m\u00e9todo de la luz clara y oscura<\/p><\/div>\n<p>Inconvenientes del m\u00e9todo de luz y oscuridad: la velocidad de parpadeo de la luz y la oscuridad solo indica la magnitud de la diferencia de frecuencia, pero no permite determinar si dicha diferencia es positiva o negativa. Adem\u00e1s, en la pr\u00e1ctica, la bombilla ya se apaga cuando la diferencia de tensi\u00f3n es inferior a 0. Por lo tanto, es necesario anticipar en cierta medida el momento del cierre del interruptor.<\/p>\n<p>(2) M\u00e9todo de la luz giratoria<\/p>\n<p>El principio del m\u00e9todo de rotaci\u00f3n de luces se muestra en la figura 2-8: tres luces se apagan por turnos, lo que produce una sensaci\u00f3n visual de rotaci\u00f3n. De este modo, el operador determina si la frecuencia del lado a conectar es superior o inferior a la de la red el\u00e9ctrica y, en funci\u00f3n de ello, decide si el generador debe funcionar a una velocidad menor o mayor. Si la luz indicadora central se apaga, significa que la fase es coherente (es decir, que los \u00e1ngulos de fase coinciden) y se puede cerrar el interruptor para poner en marcha el generador.<\/p>\n<div id=\"attachment_15379\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15379\" class=\"wp-image-15379 size-full\" title=\"9d14f15ba9b702db46520065eec86d02\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02.png\" alt=\"Figura 2-8: Principio del m\u00e9todo de rotaci\u00f3n de la luz\" width=\"790\" height=\"458\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02.png 790w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02-300x174.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02-768x445.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9d14f15ba9b702db46520065eec86d02-600x348.png 600w\" sizes=\"auto, (max-width: 790px) 100vw, 790px\" \/><p id=\"caption-attachment-15379\" class=\"wp-caption-text\">Figura 2-8: Principio del m\u00e9todo de rotaci\u00f3n de la luz<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>M\u00e9todo de tabla s\u00edncrona paralelismo cuasis\u00edncrono manual, transferencia y distribuci\u00f3n de cargas, operaci\u00f3n de desalineaci\u00f3n manual I. Paralelismo del generador s\u00edncrono 1.Comprobaci\u00f3n del estado de la red antes del paralelismo...<\/p>","protected":false},"author":1,"featured_media":15380,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15370","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/comments?post=15370"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15370\/revisions"}],"predecessor-version":[{"id":15500,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15370\/revisions\/15500"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media\/15380"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media?parent=15370"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_category?post=15370"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}