{"id":15566,"date":"2026-01-06T13:36:30","date_gmt":"2026-01-06T05:36:30","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15566"},"modified":"2026-01-06T13:36:30","modified_gmt":"2026-01-06T05:36:30","slug":"chuanbozhaomingxitongjueyuanguzhangchazhaoshixuncaozuoshouceladianfayuzhaooubiaoshiyong","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/es\/project\/chuanbozhaomingxitongjueyuanguzhangchazhaoshixuncaozuoshouceladianfayuzhaooubiaoshiyong","title":{"rendered":"Manual de formaci\u00f3n para la localizaci\u00f3n de aver\u00edas en el aislamiento de sistemas de alumbrado marino: m\u00e9todo de tracci\u00f3n y uso del mega\u00f3hmetro"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Pr\u00e1cticas de localizaci\u00f3n de fallos de aislamiento en los sistemas de iluminaci\u00f3n de buques<\/h1>\n<div style=\"display: inline-block; background: #ef9308; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; font-weight: bold; letter-spacing: 1px;\">Gu\u00eda de formaci\u00f3n pr\u00e1ctica (Practical Training Guide)<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Contenido de la operaci\u00f3n<\/h2>\n<div style=\"margin-top: 20px; padding: 0 15px;\">\n<ul style=\"list-style: none; padding: 0;\">\n<li style=\"background: #f8f9fa; padding: 12px 20px; margin-bottom: 8px; border-radius: 4px; border-left: 4px solid #1f365c;\">(1) Simulaci\u00f3n de la activaci\u00f3n de la alarma por bajo nivel de aislamiento en el circuito de iluminaci\u00f3n conectado a la red el\u00e9ctrica de 220 V;<\/li>\n<li style=\"background: #f8f9fa; padding: 12px 20px; margin-bottom: 8px; border-radius: 4px; border-left: 4px solid #1f365c;\">(2) Procedimiento del m\u00e9todo de b\u00fasqueda por desconexi\u00f3n el\u00e9ctrica;<\/li>\n<li style=\"background: #f8f9fa; padding: 12px 20px; margin-bottom: 8px; border-radius: 4px; border-left: 4px solid #1f365c;\">(3) Se utiliza un mega\u00f3hmetro manual para comprobar el aislamiento de la red el\u00e9ctrica.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">II. Pasos pr\u00e1cticos<\/h2>\n<div style=\"margin: 20px 0; padding: 0 15px;\">\n<div style=\"background: #fff4e6; border: 1px solid #ffe7c4; padding: 20px; border-radius: 8px; margin-bottom: 25px; color: #1f365c;\"><strong>\ud83d\udca1 Antecedentes t\u00e9cnicos:<\/strong>Los valores de aislamiento de la red el\u00e9ctrica del buque y de los equipos el\u00e9ctricos no deben ser inferiores a 1 M\u03a9. Existen muchos factores que pueden provocar una disminuci\u00f3n del aislamiento de los equipos el\u00e9ctricos, por lo que debemos evitarlos en la medida de lo posible; en caso de que se produzca dicha disminuci\u00f3n, hay que subsanarla sin demora. Al medir la aislamiento a tierra de la red de iluminaci\u00f3n, cuanto menor sea la resistencia de aislamiento a tierra de la red o del sistema de potencia, mayor ser\u00e1 la desviaci\u00f3n de la aguja del medidor; cuando una fase est\u00e1 conectada a tierra, la desviaci\u00f3n de la aguja del medidor alcanza su m\u00e1ximo valor, indicando una resistencia de aislamiento de 0. En el caso de los buques de nueva construcci\u00f3n, la mayor\u00eda de las sociedades de clasificaci\u00f3n ya han establecido que los sistemas de distribuci\u00f3n de energ\u00eda aislados destinados a la electricidad, la calefacci\u00f3n el\u00e9ctrica y la iluminaci\u00f3n, tanto en las redes de distribuci\u00f3n primaria como secundaria, deben estar equipados con dispositivos de monitorizaci\u00f3n continua para supervisar la resistencia de aislamiento con respecto al casco y emitir se\u00f1ales ac\u00fasticas y luminosas cuando dicha resistencia sea anormalmente baja. En cuanto la resistencia de aislamiento respecto al casco descienda por debajo de 100 \u03a9 por cada voltio de tensi\u00f3n de alimentaci\u00f3n, deber\u00e1 activarse el dispositivo de alarma.<\/div>\n<div style=\"counter-reset: step-counter;\">\n<div style=\"margin-bottom: 20px; display: flex;\"><span style=\"color: #ef9308; font-weight: bold; font-size: 20px; margin-right: 15px;\">(1)<\/span><\/p>\n<p style=\"margin: 0;\"><strong>Responder a las alarmas, silenciar y desactivar el parpadeo.<\/strong><\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; display: flex;\"><span style=\"color: #ef9308; font-weight: bold; font-size: 20px; margin-right: 15px;\">(2)<\/span><\/p>\n<p style=\"margin: 0;\">Observe la lectura del megaohm\u00edmetro de panel de distribuci\u00f3n para comprobar si es inferior a 1 M\u03a9; si es as\u00ed, se trata de un fallo de bajo aislamiento en la red el\u00e9ctrica; en caso contrario, se puede localizar el equipo con bajo aislamiento mediante m\u00e9todos de b\u00fasqueda con la alimentaci\u00f3n desconectada o con la alimentaci\u00f3n conectada.<\/p>\n<\/div>\n<div style=\"background: #f0f4f8; padding: 25px; border-radius: 8px; border: 1px solid #d1d9e6; margin-bottom: 30px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">(3) Procedimiento correcto para el m\u00e9todo de b\u00fasqueda por corte de corriente:<\/h4>\n<p style=\"margin-bottom: 10px;\"><strong>\u2460 Observaci\u00f3n de los interruptores:<\/strong>Desconecte los interruptores de alimentaci\u00f3n uno por uno, observando al mismo tiempo el megaohm\u00edmetro mientras lo hace. Si, al desconectar un interruptor, el aislamiento vuelve a la normalidad, ello indica que el equipo el\u00e9ctrico controlado por ese interruptor presenta un problema de aislamiento. A continuaci\u00f3n, conecte uno a uno los dem\u00e1s interruptores desconectados, observando al mismo tiempo la lectura del megaohm\u00edmetro; si la lectura disminuye al conectarlos, significa que el aislamiento de ese circuito es deficiente.<\/p>\n<p style=\"margin-bottom: 10px;\"><strong>\u2461 Cortar el suministro el\u00e9ctrico:<\/strong>Una vez localizado el interruptor de alimentaci\u00f3n de la l\u00ednea en la que se ha detectado un fallo de puesta a tierra, se debe cortar el suministro el\u00e9ctrico de dicha l\u00ednea.<\/p>\n<p style=\"margin-bottom: 10px;\"><strong>\u2462 Segunda b\u00fasqueda:<\/strong>En el cuadro de distribuci\u00f3n (si lo hay), utilice un mega\u00f3hmetro manual (conocido com\u00fanmente como \u00abmega\u00f3hmetro de manivela\u00bb) para localizar la red de distribuci\u00f3n secundaria. Mida uno a uno el estado de aislamiento a tierra de los circuitos derivados.<\/p>\n<p style=\"margin-bottom: 0;\"><strong>\u2463 Restablecimiento del suministro el\u00e9ctrico:<\/strong>Una vez localizado el circuito derivado conectado a tierra, desconecte el interruptor de distribuci\u00f3n de esa l\u00ednea, cierre los dem\u00e1s interruptores y, a continuaci\u00f3n, cierre el interruptor de distribuci\u00f3n de esa l\u00ednea en el cuadro el\u00e9ctrico principal para suministrar energ\u00eda al resto de equipos.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 2px dashed #1f365c; padding: 25px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">(4) Uso correcto del megaohm\u00edmetro manual:<\/h4>\n<p><strong>\u2460 Verificaci\u00f3n de calidad:<\/strong><\/p>\n<ul style=\"list-style-type: none; padding-left: 20px;\">\n<li style=\"margin-bottom: 5px;\">A. <strong>Prueba de apertura de v\u00eda:<\/strong>Agitar el megaohm\u00edmetro a una velocidad de 120 r\/min, con los dos puntales en circuito abierto; la aguja del megaohm\u00edmetro se\u00f1ala \u201c\u221e\u201d.<\/li>\n<li>B. <strong>Prueba de cortocircuito:<\/strong>Al girar ligeramente la manivela, las dos puntas del medidor se cortocircuitan y la aguja del megaohm\u00edmetro se sit\u00faa en \u201c0\u201d.<\/li>\n<\/ul>\n<p style=\"margin-top: 15px; border-top: 1px solid #eee; padding-top: 15px;\"><strong>\u2461 Localizaci\u00f3n del punto de conexi\u00f3n a tierra:<\/strong>En el caso de los sistemas de iluminaci\u00f3n, para localizar el punto de conexi\u00f3n concreto, se puede utilizar<strong>M\u00e9todo de divisi\u00f3n por mitades<\/strong>, es decir, desconectando desde la caja de conexiones central, para medir y determinar en qu\u00e9 zona concreta se ha producido la puesta a tierra. A continuaci\u00f3n, dado que cada zona peque\u00f1a cuenta con un n\u00famero limitado de puntos de alimentaci\u00f3n, se deben comprobar uno por uno, prestando especial atenci\u00f3n a los cables que salen de los portal\u00e1mparas, enchufes e interruptores, as\u00ed como al estado interno de estos elementos. Si tras estas comprobaciones no se localiza el punto de puesta a tierra, se debe inspeccionar el cable que va desde la caja de conexiones hasta el aparato el\u00e9ctrico, hasta dar con el punto de puesta a tierra.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">III. An\u00e1lisis y resoluci\u00f3n de fallos monof\u00e1sicos en el sistema de iluminaci\u00f3n<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\">\n<div style=\"flex: 1; min-width: 250px; background: #fdf2f2; border: 1px solid #f9d6d6; padding: 20px; border-radius: 8px;\">\n<p style=\"margin: 0;\"><strong>Configuraci\u00f3n del punto de fallo:<\/strong>En la red el\u00e9ctrica de iluminaci\u00f3n, la l\u00e1mpara de la cocina se ha conectado a tierra en la fase A.<\/p>\n<p style=\"margin: 10px 0 0 0; color: #b30000; font-weight: bold;\">Manifestaciones:<\/p>\n<p style=\"margin: 5px 0 0 0;\">\u201cEl indicador \u201dAC 220V BUS LOW INSUL.\u00bb parpadea y suena el zumbador, tal y como se muestra en la figura 7-5.<\/p>\n<p style=\"margin: 10px 0 0 0; font-style: italic;\">An\u00e1lisis: La luz indica que el aislamiento de la red el\u00e9ctrica es deficiente.<\/p>\n<\/div>\n<div style=\"flex: 1; min-width: 250px; text-align: center;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-15569\" title=\"51716f8b6d6ff2ca5e20db26c2703866\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/51716f8b6d6ff2ca5e20db26c2703866.png\" alt=\"51716f8b6d6ff2ca5e20db26c2703866\" width=\"92\" height=\"139\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/51716f8b6d6ff2ca5e20db26c2703866.png 376w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/51716f8b6d6ff2ca5e20db26c2703866-199x300.png 199w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/51716f8b6d6ff2ca5e20db26c2703866-8x12.png 8w\" sizes=\"auto, (max-width: 92px) 100vw, 92px\" \/><\/p>\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><strong>Figura 7-5: Alarma de fallo por bajo rendimiento del aislamiento a 220 V<\/strong><\/p>\n<\/div>\n<\/div>\n<div style=\"background: #1f365c; color: white; padding: 20px; border-radius: 8px; margin-bottom: 40px;\">\n<p style=\"margin-top: 0;\"><strong>M\u00e9todo de tratamiento:<\/strong>Silenciar y desactivar el parpadeo, confirmar la alarma y, tal y como se muestra en la figura 7-6, localizar la red secundaria en la que se ha producido el fallo de aislamiento mediante el m\u00e9todo de corte de corriente, para, a continuaci\u00f3n, identificar el punto de conexi\u00f3n a tierra concreto con un mega\u00f3hmetro manual.<\/p>\n<div style=\"display: flex; justify-content: space-around; background: #fff; color: #333; padding: 15px; border-radius: 4px; text-align: center; font-weight: bold; font-size: 12px;\">\n<div style=\"border: 1px solid #333; padding: 10px; width: 45%;\">LUZ\/ZUMBADOR: SONIDO DESACTIVADO<\/div>\n<div style=\"border: 1px solid #333; padding: 10px; width: 45%;\">FLICKER STOP<\/div>\n<\/div>\n<p style=\"font-size: 13px; text-align: center; margin-top: 10px; color: #adc6ff;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15572 aligncenter\" title=\"be47f35e2539cf964e6dcc77d23e671b\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/be47f35e2539cf964e6dcc77d23e671b.png\" alt=\"be47f35e2539cf964e6dcc77d23e671b\" width=\"183\" height=\"167\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/be47f35e2539cf964e6dcc77d23e671b.png 536w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/be47f35e2539cf964e6dcc77d23e671b-300x273.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/be47f35e2539cf964e6dcc77d23e671b-13x12.png 13w\" sizes=\"auto, (max-width: 183px) 100vw, 183px\" \/><\/p>\n<p style=\"font-size: 13px; text-align: center; margin-top: 10px; color: #adc6ff;\">Figura 7-6: Botones de gesti\u00f3n de alertas<\/p>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #ef9308; padding-bottom: 10px; margin-bottom: 25px;\">Gu\u00eda pr\u00e1ctica para todo el proceso (SOP)<\/h3>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px;\">\n<div style=\"flex: 2; min-width: 350px;\">\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(1) Verificaci\u00f3n del estado:<\/strong>La luz de puesta a tierra y el mega\u00f3hmetro del cuadro de distribuci\u00f3n se muestran en la figura 7-7. Al pulsar el bot\u00f3n de la luz de puesta a tierra, la luz de la fase A se apaga, lo que indica que la fase A est\u00e1 a tierra. Al encender el mega\u00f3hmetro del cuadro de distribuci\u00f3n para medir la red de alumbrado, el indicador del mega\u00f3hmetro marca 0 en ese momento.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(2) Comprobaci\u00f3n de la pantalla principal:<\/strong>Delante del cuadro el\u00e9ctrico principal, desconecte uno a uno los interruptores de distribuci\u00f3n de la iluminaci\u00f3n y compruebe si la lectura del megaohm\u00edmetro vuelve a los valores normales.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px; background: #fef9f3; padding: 10px; border-radius: 4px;\"><strong style=\"color: #1f365c;\">(3) Recomendaciones sobre el orden de desconexi\u00f3n:<\/strong>Zona de alojamiento de la tripulaci\u00f3n \u2192 Zona de iluminaci\u00f3n de cubierta \u2192 Zona de iluminaci\u00f3n de la sala de m\u00e1quinas \u2192 Instalaciones de comunicaci\u00f3n y navegaci\u00f3n del puente de mando.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(4) Localizaci\u00f3n de aver\u00edas:<\/strong>Una vez localizado el interruptor de distribuci\u00f3n en el que se ha producido el fallo de puesta a tierra, corte el suministro de esa l\u00ednea y compruebe si la lectura del megaohm\u00edmetro vuelve a los valores normales.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(5) Segunda b\u00fasqueda:<\/strong>Antes de acceder a la caja de distribuci\u00f3n, utilice un mega\u00f3hmetro manual para localizar la red de distribuci\u00f3n secundaria y compruebe uno por uno el estado de aislamiento a tierra de los circuitos derivados.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(6) Recuperaci\u00f3n parcial:<\/strong>Una vez localizado el circuito derivado conectado a tierra, desconecte el interruptor de distribuci\u00f3n de esa l\u00ednea, cierre los dem\u00e1s interruptores y, a continuaci\u00f3n, cierre el interruptor de distribuci\u00f3n de esa l\u00ednea situado delante del cuadro el\u00e9ctrico principal para restablecer el suministro el\u00e9ctrico.<\/div>\n<div style=\"margin-bottom: 15px; border-bottom: 1px solid #eee; padding-bottom: 10px;\"><strong style=\"color: #ef9308;\">(7) Divisi\u00f3n por zonas:<\/strong>A la hora de localizar un punto de conexi\u00f3n a tierra concreto, se debe desconectar la caja de conexiones intermedia (por ejemplo, la situada entre dos habitaciones) para determinar qu\u00e9 zona concreta (por ejemplo, una habitaci\u00f3n) est\u00e1 conectada a tierra.<\/div>\n<div style=\"margin-bottom: 0;\"><strong style=\"color: #ef9308;\">(8) Verificaci\u00f3n minuciosa:<\/strong>En las zonas peque\u00f1as (habitaciones) solo hay un n\u00famero limitado de puntos de alimentaci\u00f3n, que por lo general no supera los 5; se deben revisar uno por uno, prestando especial atenci\u00f3n a los cables que salen de los portal\u00e1mparas, enchufes e interruptores, y comprobando el estado interno de estos elementos. Si tras estas comprobaciones sigue sin localizarse el punto de conexi\u00f3n a tierra, se debe inspeccionar el cableado entre la caja de conexiones y los aparatos el\u00e9ctricos hasta encontrar el punto de fallo de la conexi\u00f3n a tierra.<\/div>\n<\/div>\n<div style=\"flex: 1; min-width: 250px; text-align: center;\">\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-15573\" title=\"96c1ee50645ce24a944a0ba816545a5d\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/96c1ee50645ce24a944a0ba816545a5d.png\" alt=\"96c1ee50645ce24a944a0ba816545a5d\" width=\"323\" height=\"408\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/96c1ee50645ce24a944a0ba816545a5d.png 534w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/96c1ee50645ce24a944a0ba816545a5d-238x300.png 238w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/96c1ee50645ce24a944a0ba816545a5d-10x12.png 10w\" sizes=\"auto, (max-width: 323px) 100vw, 323px\" \/>\u56fe <strong>7-7 L\u00e1mpara de tierra y megohmetro para cuadros de distribuci\u00f3n<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Manual de formaci\u00f3n pr\u00e1ctica para t\u00e9cnicos en electr\u00f3nica y electricidad naval (ETO) | Clase pr\u00e1ctica sobre detecci\u00f3n de fallos de aislamiento | Revisi\u00f3n de 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Gu\u00eda de formaci\u00f3n pr\u00e1ctica sobre localizaci\u00f3n de aver\u00edas en el aislamiento del sistema de alumbrado de buques (Gu\u00eda de formaci\u00f3n pr\u00e1ctica) I. Operar ...<\/p>","protected":false},"author":1,"featured_media":15568,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15566","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/comments?post=15566"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15566\/revisions"}],"predecessor-version":[{"id":15574,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15566\/revisions\/15574"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media\/15568"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media?parent=15566"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_category?post=15566"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}