{"id":15608,"date":"2026-01-06T16:31:14","date_gmt":"2026-01-06T08:31:14","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15608"},"modified":"2026-01-06T16:31:14","modified_gmt":"2026-01-06T08:31:14","slug":"chuanbo-6600v-gaoyadianlixitonganquancaozuoshiwudanxiantushiduwufangcuoshiyupeidianpingweihu","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/es\/project\/chuanbo-6600v-gaoyadianlixitonganquancaozuoshiwudanxiantushiduwufangcuoshiyupeidianpingweihu","title":{"rendered":"Pr\u00e1cticas de seguridad del sistema de alimentaci\u00f3n de AT del buque 6600 V: lectura de esquemas unifilares, cinco medidas preventivas y mantenimiento del cuadro de distribuci\u00f3n"},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #ef9308; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Pr\u00e1cticas de seguridad en el manejo de equipos de alta presi\u00f3n a bordo de buques<\/h1>\n<div style=\"display: inline-block; background: #c0392b; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; letter-spacing: 1px; font-weight: bold;\">SISTEMA DE GESTI\u00d3N DE LA SEGURIDAD DE ALTA TENSI\u00d3N (AT)<\/div>\n<\/div>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">I. Estructura y composici\u00f3n del cuadro de distribuci\u00f3n principal de alta tensi\u00f3n<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">1. Interpretaci\u00f3n de esquemas unifilares de los sistemas el\u00e9ctricos de alta tensi\u00f3n de los buques<\/h3>\n<p style=\"text-indent: 2em; margin-bottom: 15px;\">Mediante el esquema unifilar del sistema el\u00e9ctrico de alta tensi\u00f3n del software de simulaci\u00f3n, se comprender\u00e1 la composici\u00f3n y los principales equipos del sistema el\u00e9ctrico de alta tensi\u00f3n. Compar\u00e1ndolo con el cuadro de distribuci\u00f3n de alta tensi\u00f3n de la simulaci\u00f3n, se aprender\u00e1 la disposici\u00f3n de los equipos de conmutaci\u00f3n. La figura 11-1 muestra el esquema unifilar del sistema el\u00e9ctrico de alta tensi\u00f3n de un buque.<\/p>\n<\/div>\n<\/section>\n<\/div>\n<div id=\"attachment_15613\" style=\"width: 537px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15613\" class=\"wp-image-15613\" title=\"f2244c27cbdde477acf2f30bfa683903-3\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3.png\" alt=\"Figura 11-1: Esquema unifilar del sistema el\u00e9ctrico de alta tensi\u00f3n de un buque\" width=\"527\" height=\"296\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3.png 954w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3-300x169.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3-768x431.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f2244c27cbdde477acf2f30bfa683903-3-600x337.png 600w\" sizes=\"auto, (max-width: 527px) 100vw, 527px\" \/><p id=\"caption-attachment-15613\" class=\"wp-caption-text\">Figura 11-1: Esquema unifilar del sistema el\u00e9ctrico de alta tensi\u00f3n de un buque<\/p><\/div>\n<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<section style=\"margin-bottom: 60px;\">\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<div style=\"background: #f0f4f8; padding: 20px; border-radius: 8px; margin: 20px 0;\">\n<p><strong>(1) Identificaci\u00f3n de los equipos esenciales:<\/strong>Leer el esquema unifilar e identificar los principales equipos de alta tensi\u00f3n, como generadores de alta tensi\u00f3n, interruptores autom\u00e1ticos de alta tensi\u00f3n, seccionadores de alta tensi\u00f3n, interruptores de puesta a tierra de alta tensi\u00f3n, barras colectoras de alta tensi\u00f3n y transformadores de alta tensi\u00f3n.<\/p>\n<p><strong>(2) Identificaci\u00f3n de la carga:<\/strong>En el esquema unifilar, identifica las principales cargas de alta tensi\u00f3n.<\/p>\n<p><strong>(3) Conexi\u00f3n del sistema:<\/strong>En el esquema unifilar, ind\u00edquese la relaci\u00f3n de conexi\u00f3n entre el sistema de alta tensi\u00f3n y el de baja tensi\u00f3n.<\/p>\n<\/div>\n<p style=\"text-indent: 2em; border-left: 4px solid #1f365c; padding-left: 15px; background: #f9f9f9; padding: 15px;\"><strong>An\u00e1lisis l\u00f3gico:<\/strong>Como se muestra en la figura 11-1, la barra colectora de alta tensi\u00f3n est\u00e1 dividida en dos tramos, a babor y a estribor, mediante dos interruptores de conexi\u00f3n de barras de alta tensi\u00f3n: HBUS TIE1 y HBUS TIE2; los dos generadores principales est\u00e1n conectados directamente a la barra colectora de alta tensi\u00f3n de babor (HBBA), mientras que los otros dos generadores principales est\u00e1n conectados directamente a la barra colectora de alta tensi\u00f3n de estribor (HBBB); la configuraci\u00f3n de la subestaci\u00f3n el\u00e9ctrica de alta tensi\u00f3n del buque es de tipo monob\u00fas segmentado.<\/p>\n<p>El busbar de alta tensi\u00f3n de babor (HBBA) y el de estribor (HBBB) transforman, a trav\u00e9s de los transformadores de alta tensi\u00f3n TR1 y TR2 respectivamente, la alta tensi\u00f3n de 6.600 V en baja tensi\u00f3n de 400 V, con lo que alimentan el busbar de baja tensi\u00f3n de 400 V (MBB). El bus de alta tensi\u00f3n de babor (HBBA) y el de estribor (HBBB) alimentan, respectivamente, a los transformadores de alta tensi\u00f3n de propulsi\u00f3n PTR1 y PTR2, situados en babor y estribor, y estos, a su vez, suministran energ\u00eda a los motores el\u00e9ctricos de propulsi\u00f3n principales del buque.<\/p>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">2. Identificaci\u00f3n de los componentes de los cuadros de distribuci\u00f3n de alta tensi\u00f3n de los buques<\/h3>\n<p style=\"text-indent: 2em;\">Los sistemas el\u00e9ctricos de alta tensi\u00f3n de los buques suelen reducir la alta tensi\u00f3n a baja tensi\u00f3n mediante transformadores de alta tensi\u00f3n, con el fin de suministrar energ\u00eda a las cargas del sistema el\u00e9ctrico de baja tensi\u00f3n del buque. Adem\u00e1s de los cuadros de control de los generadores, los cuadros de control de sincronizaci\u00f3n y los cuadros de carga, tambi\u00e9n hay cuadros de transformadores reductores y cuadros de conexi\u00f3n de barras colectoras, entre otros.<\/p>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 25px; border-radius: 8px; margin-top: 20px; box-shadow: 0 4px 10px rgba(0,0,0,0.05);\"><strong style=\"color: #c0392b; font-size: 18px;\">Diferencias notables entre los cuadros de distribuci\u00f3n de alta tensi\u00f3n y los de baja tensi\u00f3n:<\/strong><\/p>\n<ul style=\"margin-top: 15px;\">\n<li style=\"margin-bottom: 10px;\"><strong>(1) Aislamiento estructural:<\/strong>Cada pantalla cuenta con un solo circuito; en su interior dispone de estructuras funcionales aisladas entre s\u00ed, como la sala de interruptores, la sala de cables y la sala de baja tensi\u00f3n.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>(2) Sistema de interbloqueo de las cinco medidas de prevenci\u00f3n:<\/strong>En el interior se aplican requisitos operativos estrictos de protecci\u00f3n mediante enclavamientos, conocidos com\u00fanmente como las \u201ccinco medidas de prevenci\u00f3n\u201d.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>(3) Canal de descarga del arco:<\/strong>La parte superior cuenta con un canal de descarga de arco y una placa de despresurizaci\u00f3n, que sirven para liberar de forma segura los gases nocivos y los iones met\u00e1licos en caso de que se produzca un arco el\u00e9ctrico en el interior.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>(4) Tipo de interruptor:<\/strong>En la gran mayor\u00eda de los casos se utilizan interruptores de vac\u00edo extra\u00edbles, interruptores de SF\u2086, etc.<\/li>\n<li style=\"margin-bottom: 10px;\"><strong>(5) Seccionamiento de barras:<\/strong>De acuerdo con los requisitos de la norma CCS, debe dividirse en al menos dos secciones independientes. El cuadro de elevaci\u00f3n (o cuadro de conmutaci\u00f3n de la l\u00ednea principal) es una estructura espec\u00edfica propia de los cuadros de distribuci\u00f3n de alta tensi\u00f3n.<\/li>\n<li style=\"margin-bottom: 0;\"><strong>(6) Protecci\u00f3n por rel\u00e9s:<\/strong>Las funciones de protecci\u00f3n espec\u00edficas de la alta tensi\u00f3n, como la diferencia longitudinal, la secuencia cero y la puesta a tierra del rotor, se implementan mediante rel\u00e9s multifunci\u00f3n digitales independientes.<\/li>\n<\/ul>\n<\/div>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 30px; align-items: center; justify-content: center;\">\n<div style=\"flex: 1; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15614\" title=\"aede5f51f7c3d7f2d12eb0e985cfca51\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51.png\" alt=\"aede5f51f7c3d7f2d12eb0e985cfca51\" width=\"926\" height=\"611\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51.png 926w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51-300x198.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51-768x507.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51-18x12.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/aede5f51f7c3d7f2d12eb0e985cfca51-600x396.png 600w\" sizes=\"auto, (max-width: 926px) 100vw, 926px\" \/> Figura 11-2: Imagen real de un cuadro de distribuci\u00f3n de alta tensi\u00f3n<\/div>\n<div style=\"flex: 1; text-align: center;\">[<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15615\" title=\"c88317dfbb482c1db94b5c0d2825dcef\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef.png\" alt=\"c88317dfbb482c1db94b5c0d2825dcef\" width=\"822\" height=\"1304\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef.png 822w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef-189x300.png 189w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef-645x1024.png 645w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef-768x1218.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef-8x12.png 8w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c88317dfbb482c1db94b5c0d2825dcef-600x952.png 600w\" sizes=\"auto, (max-width: 822px) 100vw, 822px\" \/>Figura 11-3: Esquema de la estructura interna de un cuadro de distribuci\u00f3n de alta tensi\u00f3n, en el que se muestran la c\u00e1mara de interruptores, la c\u00e1mara de barras, etc.<\/div>\n<\/div>\n<p style=\"margin-top: 25px; text-indent: 2em;\">Dado que el punto de apertura de los interruptores no es visible desde el exterior, para garantizar la seguridad del personal de mantenimiento, se han conectado en serie entre el generador principal, la desconexi\u00f3n de la barra colectora y los interruptores del transformador y la barra colectora<strong>Interruptor de aislamiento<\/strong>. Al mismo tiempo, se han instalado varios dispositivos en las l\u00edneas de suministro y distribuci\u00f3n el\u00e9ctrica<strong>Interruptor de puesta a tierra<\/strong>, y aseg\u00farese de que las l\u00edneas de contacto no est\u00e9n bajo tensi\u00f3n.<\/p>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">II. Detecci\u00f3n de alta tensi\u00f3n<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"text-indent: 2em;\">Consultar el estado de los indicadores de alta tensi\u00f3n de los generadores conectados a la red y los que no lo est\u00e1n.<strong>Indicador de alta tensi\u00f3n en servicio<\/strong>Es un dispositivo de seguridad de advertencia que se instala directamente en equipos el\u00e9ctricos de alta tensi\u00f3n. La tensi\u00f3n nominal de la alta tensi\u00f3n se clasifica en los siguientes niveles: 3 kV, 6 kV, 10 kV, 27,5 kV y 35 kV.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; align-items: center; background: #fafafa; padding: 20px; border-radius: 8px; border: 1px solid #eee;\">\n<div style=\"flex: 2;\">\n<p>Como se muestra en la figura 11-4, cuando el equipo est\u00e1 bajo tensi\u00f3n de funcionamiento, el indicador parpadea. Este dispositivo sirve para evitar errores de manejo el\u00e9ctrico. El indicador de presencia de alta tensi\u00f3n est\u00e1 compuesto por un sensor, cables y un indicador con LED.<strong>Procedimiento operativo:<\/strong>Al pulsar el bot\u00f3n de autocomprobaci\u00f3n del indicador del generador que no est\u00e1 en funcionamiento, se enciende el indicador de bloqueo y, tras unos segundos, se apaga, lo cual es normal.<\/p>\n<p>Cuando el grupo electr\u00f3geno est\u00e1 en funcionamiento, tambi\u00e9n se pueden leer en el cuadro de instrumentos par\u00e1metros como la tensi\u00f3n, la corriente y la potencia (como se muestra en la figura 11-5).<\/p>\n<\/div>\n<div style=\"flex: 1; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15616\" title=\"4375008dc1cb3ebfcc0aeb6060abda6b\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4375008dc1cb3ebfcc0aeb6060abda6b.png\" alt=\"4375008dc1cb3ebfcc0aeb6060abda6b\" width=\"759\" height=\"620\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4375008dc1cb3ebfcc0aeb6060abda6b.png 759w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4375008dc1cb3ebfcc0aeb6060abda6b-300x245.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4375008dc1cb3ebfcc0aeb6060abda6b-15x12.png 15w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/4375008dc1cb3ebfcc0aeb6060abda6b-600x490.png 600w\" sizes=\"auto, (max-width: 759px) 100vw, 759px\" \/>Figura 11-4: Indicador de alta tensi\u00f3n y botones de prueba<\/p>\n<p style=\"font-size: 13px; color: #666; margin-top: 10px;\">\n<\/div>\n<\/div>\n<div style=\"text-align: center; margin-top: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-15617\" title=\"144f01c4748fb588a25eaef74df89c08\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/144f01c4748fb588a25eaef74df89c08.png\" alt=\"144f01c4748fb588a25eaef74df89c08\" width=\"482\" height=\"280\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/144f01c4748fb588a25eaef74df89c08.png 758w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/144f01c4748fb588a25eaef74df89c08-300x174.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/144f01c4748fb588a25eaef74df89c08-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/144f01c4748fb588a25eaef74df89c08-600x348.png 600w\" sizes=\"auto, (max-width: 482px) 100vw, 482px\" \/><\/div>\n<div style=\"text-align: center; margin-top: 20px;\">Figura 11-5: Indicadores del panel de control de un grupo electr\u00f3geno de alta tensi\u00f3n en funcionamiento<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 60px;\">\n<h2 style=\"background: #c0392b; color: #fff; padding: 15px 25px; border-left: 10px solid #333; border-radius: 4px; font-size: 22px;\">III. Normas fundamentales de las \u201ccinco medidas de prevenci\u00f3n\u201d en los sistemas el\u00e9ctricos de alta tensi\u00f3n<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"margin-bottom: 20px; font-weight: bold; color: #c0392b;\">Contenido concreto de las \u201ccinco medidas de prevenci\u00f3n\u201d para los cuadros de distribuci\u00f3n de alta tensi\u00f3n de los buques:<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px;\">\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 6px; border-top: 4px solid #c0392b;\"><strong>(1) Prevenci\u00f3n de la apertura y el cierre err\u00f3neos de los interruptores de alta tensi\u00f3n:<\/strong>Se ha incorporado un dise\u00f1o de protecci\u00f3n en los botones para evitar manejos err\u00f3neos durante el funcionamiento normal.<\/div>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 6px; border-top: 4px solid #c0392b;\"><strong>(2) Evitar abrir y cerrar el seccionador en carga:<\/strong>Solo una vez que se haya abierto el interruptor, se podr\u00e1n desactivar los enclavamientos mec\u00e1nicos y el\u00e9ctricos.<\/div>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 6px; border-top: 4px solid #c0392b;\"><strong>(3) Prevenci\u00f3n de la activaci\u00f3n (cierre) del interruptor de puesta a tierra bajo tensi\u00f3n:<\/strong>Solo se podr\u00e1 cerrar el interruptor cuando este se encuentre en la posici\u00f3n de prueba.<\/div>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 6px; border-top: 4px solid #c0392b;\"><strong>(4) Evitar accionar el interruptor cuando el cable de tierra est\u00e9 conectado:<\/strong>El interruptor de puesta a tierra debe estar en posici\u00f3n de apertura para que el interruptor autom\u00e1tico pueda colocarse en posici\u00f3n de trabajo.<\/div>\n<div style=\"background: #fff; border: 1px solid #ddd; padding: 20px; border-radius: 6px; border-top: 4px solid #c0392b;\"><strong>(5) Evitar el acceso accidental a los compartimentos bajo tensi\u00f3n:<\/strong>Cuando el interruptor de puesta a tierra est\u00e1 en posici\u00f3n de corte, no es posible abrir la puerta inferior ni la puerta trasera del armario de distribuci\u00f3n.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 40px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 15px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 22px;\">IV. Pr\u00e1cticas de manejo y gesti\u00f3n de los cuadros de distribuci\u00f3n de alta tensi\u00f3n<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<p style=\"text-indent: 2em; margin-bottom: 20px;\">Los principales aspectos de la gesti\u00f3n operativa incluyen: verificaci\u00f3n de instrucciones, prueba de luces de prueba, prueba de aislamiento, prueba de luces de puesta a tierra, registro de par\u00e1metros y prueba de las funciones de alarma del sistema, entre otros.<\/p>\n<div style=\"border: 1px solid #1f365c; border-radius: 12px; overflow: hidden; margin-bottom: 30px;\">\n<div style=\"background: #1f365c; color: white; padding: 12px 20px; font-weight: bold;\">N.\u00ba 2: Detalles sobre el manejo del panel de control del generador di\u00e9sel<\/div>\n<div style=\"padding: 20px;\">\n<p>\u25cf <strong>Indicador de estado:<\/strong>\u201cLa luz roja \u201dES OFF\u201c indica que el interruptor de puesta a tierra est\u00e1 abierto; la luz verde \u201dES ON\u00bb indica que el interruptor de puesta a tierra est\u00e1 cerrado.<\/p>\n<p>\u25cf <strong>Protecci\u00f3n integral:<\/strong>La unidad HIMAP-BC se encarga de la medici\u00f3n, el control y la protecci\u00f3n, y desconecta el dispositivo en caso de anomal\u00eda.<\/p>\n<p>\u25cf <strong>Cambio de control:<\/strong>El interruptor giratorio incluye la selecci\u00f3n del modo de control, la apertura y el cierre del disyuntor y el interruptor de arranque y parada.<strong>Puntos clave:<\/strong>Al extraerlo hasta la posici\u00f3n de prueba, el interruptor de aislamiento se abre; al empujarlo hasta la posici\u00f3n de trabajo, se cierra.<\/p>\n<div id=\"attachment_15618\" style=\"width: 466px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15618\" class=\"wp-image-15618\" title=\"edba761947d23a8304a746e2abb236da\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/edba761947d23a8304a746e2abb236da.png\" alt=\"Figura 11-6: Panel de control del generador di\u00e9sel n.\u00ba 2\" width=\"456\" height=\"262\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/edba761947d23a8304a746e2abb236da.png 766w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/edba761947d23a8304a746e2abb236da-300x172.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/edba761947d23a8304a746e2abb236da-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/edba761947d23a8304a746e2abb236da-600x345.png 600w\" sizes=\"auto, (max-width: 456px) 100vw, 456px\" \/><p id=\"caption-attachment-15618\" class=\"wp-caption-text\">Figura 11-6: Panel de control del generador di\u00e9sel n.\u00ba 2<\/p><\/div>\n<div style=\"text-align: center;\">\n<div id=\"attachment_15619\" style=\"width: 469px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15619\" class=\"wp-image-15619\" title=\"c1d5e07aedd5dbdb1f56afb10f8fda53\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53.png\" alt=\"Figura 11-7: Panel de control junto al generador n.\u00ba 2\" width=\"459\" height=\"248\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53.png 910w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53-300x162.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53-768x414.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/c1d5e07aedd5dbdb1f56afb10f8fda53-600x324.png 600w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><p id=\"caption-attachment-15619\" class=\"wp-caption-text\">Figura 11-7: Panel de control junto al generador n.\u00ba 2<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 20px;\">\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">Inspecci\u00f3n del panel del transformador reductor de tensi\u00f3n<\/h4>\n<p>Tal y como se muestra en la figura 11-8, compruebe las lecturas de tensi\u00f3n y corriente, as\u00ed como el estado del interruptor autom\u00e1tico. Gire el interruptor para controlar el modo de funcionamiento y la apertura y cierre del interruptor. Observe el indicador luminoso \u00abES\u00bb para confirmar el estado de la conexi\u00f3n a tierra.<\/p>\n<div id=\"attachment_15621\" style=\"width: 490px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15621\" class=\"wp-image-15621\" title=\"9fafdb00593c2b6bac345939e7f9c8db-1\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1.png\" alt=\"Figura 11-8: Cuadro del transformador reductor n.\u00ba 1\" width=\"480\" height=\"272\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1.png 922w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1-300x170.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1-768x435.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/9fafdb00593c2b6bac345939e7f9c8db-1-600x340.png 600w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><p id=\"caption-attachment-15621\" class=\"wp-caption-text\">Figura 11-8: Cuadro del transformador reductor n.\u00ba 1<\/p><\/div>\n<\/div>\n<div style=\"background: #eef2f7; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0;\">Prueba de iluminaci\u00f3n y de aislamiento<\/h4>\n<p>Tal y como se muestra en la figura 11-9, pulse el bot\u00f3n de prueba de l\u00e1mparas para comprobar el estado de los indicadores generales. Pulse el bot\u00f3n de prueba de aislamiento y observe si la aguja del megaohm\u00edmetro del cuadro de distribuci\u00f3n se desplaza hacia el 0 para confirmar su funcionamiento.<\/p>\n<div id=\"attachment_15623\" style=\"width: 486px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15623\" class=\"wp-image-15623\" title=\"26ae1d96af297da453f6ebe919c662b0-1\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1.png\" alt=\"Figura 11-9: Prueba de iluminaci\u00f3n y de aislamiento del cuadro de alimentaci\u00f3n n.\u00ba 1\" width=\"476\" height=\"276\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1.png 908w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1-300x174.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1-768x445.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1-18x10.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/26ae1d96af297da453f6ebe919c662b0-1-600x348.png 600w\" sizes=\"auto, (max-width: 476px) 100vw, 476px\" \/><p id=\"caption-attachment-15623\" class=\"wp-caption-text\">Figura 11-9: Prueba de iluminaci\u00f3n y de aislamiento del cuadro de alimentaci\u00f3n n.\u00ba 1<\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 80px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Material did\u00e1ctico de formaci\u00f3n t\u00e9cnica para t\u00e9cnicos en electr\u00f3nica y electricidad naval (ETO) | Cap\u00edtulo sobre seguridad en el manejo de alta tensi\u00f3n | Edici\u00f3n revisada de 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>SISTEMA DE GESTI\u00d3N DE LA SEGURIDAD EN ALTA TENSI\u00d3...<\/p>","protected":false},"author":1,"featured_media":15609,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15608","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/comments?post=15608"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15608\/revisions"}],"predecessor-version":[{"id":15624,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15608\/revisions\/15624"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media\/15609"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media?parent=15608"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_category?post=15608"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}