{"id":15631,"date":"2026-01-06T16:46:18","date_gmt":"2026-01-06T08:46:18","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15631"},"modified":"2026-01-06T16:46:18","modified_gmt":"2026-01-06T08:46:18","slug":"chuanbo-6600v-gaoyaxitongjianxiushiwufadianjiweihuduanluqiyaochuyujiedekaiguancaozuo-sop","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/es\/project\/chuanbo-6600v-gaoyaxitongjianxiushiwufadianjiweihuduanluqiyaochuyujiedekaiguancaozuo-sop","title":{"rendered":"Pr\u00e1cticas de revisi\u00f3n del sistema de alta tensi\u00f3n de 6600 V del buque: mantenimiento del generador, apertura del disyuntor y operaci\u00f3n del interruptor de tierra."},"content":{"rendered":"<div style=\"font-family: 'Segoe UI', Arial, sans-serif; line-height: 1.8; color: #333; max-width: 1100px; margin: 0 auto; background: #fff; padding: 20px;\">\n<div style=\"text-align: center; border-bottom: 5px solid #1f365c; padding-bottom: 30px; margin-bottom: 40px;\">\n<h1 style=\"color: #1f365c; font-size: 30px; margin-bottom: 10px; font-weight: bold;\">Procedimientos de revisi\u00f3n de interruptores principales de alta tensi\u00f3n<\/h1>\n<div style=\"display: inline-block; background: #ef9308; color: #fff; padding: 6px 20px; border-radius: 4px; font-size: 14px; font-weight: bold; letter-spacing: 1px;\">\u26a0\ufe0f Peligros de alta tensi\u00f3n: Cumplimiento estricto de los procedimientos operativos y los requisitos de enclavamiento<\/div>\n<\/div>\n<section style=\"margin-bottom: 50px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">I. Procedimientos de revisi\u00f3n del interruptor principal de alta tensi\u00f3n del buque<\/h2>\n<div style=\"margin-top: 25px; padding: 0 15px;\">\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px;\">(i) Procedimientos operativos de revisi\u00f3n del interruptor principal de alta tensi\u00f3n del buque<\/h3>\n<p style=\"text-indent: 2em;\">Los cuadros de distribuci\u00f3n de alta tensi\u00f3n suelen estar divididos en los lados izquierdo y derecho, que se colocan en diferentes salas de cuadros de distribuci\u00f3n de alta tensi\u00f3n, que est\u00e1n equipadas con suelos aislados de alta tensi\u00f3n y cuadros de distribuci\u00f3n de alta tensi\u00f3n con un nivel de protecci\u00f3n muy alto para garantizar la seguridad de los operarios.<\/p>\n<div style=\"display: flex; gap: 20px; margin: 20px 0; flex-wrap: wrap;\">\n<div style=\"flex: 1; min-width: 300px; background: #fdf2f2; padding: 20px; border-radius: 8px; border-left: 5px solid #c0392b;\"><strong style=\"color: #c0392b;\">Proceso de inspecci\u00f3n:<\/strong><br \/>\nColoque el interruptor principal de AT del buque en posici\u00f3n de desconexi\u00f3n \u2192 desconecte el seccionador correspondiente \u2192 cierre el seccionador de puesta a tierra \u2192 abra el armario de distribuci\u00f3n \u2192 ponga en servicio el disyuntor de AT.<\/div>\n<div style=\"flex: 1; min-width: 300px; background: #f0f9eb; padding: 20px; border-radius: 8px; border-left: 5px solid #67c23a;\"><strong style=\"color: #67c23a;\">Proceso de recuperaci\u00f3n:<\/strong><br \/>\nCierre la aparamenta \u2192 desconecte el interruptor de puesta a tierra \u2192 cierre el interruptor seccionador correspondiente \u2192 coloque el interruptor principal de AT del buque en posici\u00f3n de trabajo.<\/div>\n<\/div>\n<p style=\"background: #fff8e6; padding: 10px 15px; border-radius: 4px; font-size: 14px; color: #856404;\">* :: Se han previsto enclavamientos el\u00e9ctricos o mec\u00e1nicos entre el interruptor principal, el seccionador y el seccionador de puesta a tierra y la puerta del armario para evitar maniobras err\u00f3neas. Los operarios deben seguir el proceso paso a paso.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(400px, 1fr)); gap: 25px; margin-top: 30px;\">\n<div style=\"border: 1px solid #ddd; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0; border-left: 4px solid #1f365c; padding-left: 10px;\">(ii) Procedimientos operativos del interruptor de desconexi\u00f3n de alta tensi\u00f3n del buque<\/h4>\n<p style=\"font-size: 14px;\">Interruptores de desconexi\u00f3n con puntos de ruptura visibles.<strong>Sin dispositivo de extinci\u00f3n de arco, no puede abrir y cerrar la puerta con carga.<\/strong>. Debe funcionar con el disyuntor: el seccionador s\u00f3lo puede desconectarse despu\u00e9s de que se haya desconectado el disyuntor; el disyuntor no puede romper el seccionador cuando est\u00e1 en posici\u00f3n cerrada. A la inversa, el seccionador debe estar cerrado antes de que el disyuntor pueda cerrarse.<\/p>\n<\/div>\n<div style=\"border: 1px solid #ddd; padding: 20px; border-radius: 8px;\">\n<h4 style=\"color: #1f365c; margin-top: 0; border-left: 4px solid #1f365c; padding-left: 10px;\">(iii) Procedimientos de operaci\u00f3n del seccionador de puesta a tierra de alta tensi\u00f3n<\/h4>\n<p style=\"font-size: 14px;\">sin dispositivo de extinci\u00f3n de arcos.<strong>No abra ni cierre el port\u00f3n con carga<\/strong>. Debe cerrarse cuando se interrumpe el suministro el\u00e9ctrico para realizar tareas de mantenimiento, a fin de garantizar que la l\u00ednea est\u00e9 conectada a tierra de forma fiable para evitar que la acumulaci\u00f3n de carga el\u00e9ctrica afecte al personal o provoque un cortocircuito de tres elementos para disparar el disyuntor inmediatamente cuando se cierre accidentalmente el disyuntor. Despu\u00e9s del mantenimiento, la secuencia es: abrir el interruptor de puesta a tierra \u2192 cerrar el interruptor de desconexi\u00f3n \u2192 cerrar el disyuntor.<\/p>\n<\/div>\n<\/div>\n<h3 style=\"color: #1f365c; border-bottom: 2px solid #eee; padding-bottom: 8px; margin-top: 40px;\">(iv) Operaciones de retirada y alimentaci\u00f3n del interruptor principal de alta tensi\u00f3n<\/h3>\n<div style=\"background: #fafafa; padding: 25px; border-radius: 12px; border: 1px solid #eee;\">\n<p><strong>(1) Preparaci\u00f3n:<\/strong>Finalizaci\u00f3n de las operaciones de disparo, apagado y desmagnetizaci\u00f3n de los disyuntores de alta tensi\u00f3n antes de la revisi\u00f3n del generador y del panel de control.<\/p>\n<p><strong>(2) Desconexi\u00f3n del aislamiento:<\/strong>Utilizar un disyuntor para pasar a<strong>lugar de la prueba<\/strong>m\u00e9todo de desconexi\u00f3n del disyuntor de la barra colectora.<\/p>\n<p><strong>(3) Conexi\u00f3n a tierra:<\/strong>Abra la puerta de operaci\u00f3n de puesta a tierra, cierre el interruptor de puesta a tierra utilizando la manija de operaci\u00f3n de puesta a tierra y observe la indicaci\u00f3n de cierre de puesta a tierra del tablero.<\/p>\n<p><strong>(4) Gire hacia fuera hasta la posici\u00f3n de servicio:<\/strong>Contin\u00fae basculando hasta la posici\u00f3n de servicio, abra la puerta del armario y desconecte el enchufe secundario. Utilice el carro especial para bloquear y, a continuaci\u00f3n, tire del disyuntor hacia el carro (Figura 11-12).<br \/>\n<span style=\"color: #d35400; font-weight: bold;\">* Nota: Despu\u00e9s de completar la conexi\u00f3n a tierra, utilice un comprobador de alta tensi\u00f3n para confirmar que no hay electricidad antes de realizar el mantenimiento.<\/span><\/p>\n<div id=\"attachment_15632\" style=\"width: 281px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15632\" class=\"wp-image-15632\" title=\"5e0f96bd2ce0c17c1b14d431ab1585b2\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5e0f96bd2ce0c17c1b14d431ab1585b2.png\" alt=\"Figura 11-12 Diagrama esquem\u00e1tico del disyuntor de alta tensi\u00f3n puesto en posici\u00f3n de servicio\" width=\"271\" height=\"300\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5e0f96bd2ce0c17c1b14d431ab1585b2.png 456w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5e0f96bd2ce0c17c1b14d431ab1585b2-271x300.png 271w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/5e0f96bd2ce0c17c1b14d431ab1585b2-11x12.png 11w\" sizes=\"auto, (max-width: 271px) 100vw, 271px\" \/><p id=\"caption-attachment-15632\" class=\"wp-caption-text\">Figura 11-12 Diagrama esquem\u00e1tico del disyuntor de alta tensi\u00f3n puesto en posici\u00f3n de servicio<\/p><\/div>\n<p><strong>(5) Funcionamiento a presi\u00f3n:<\/strong>Utilice el carro para empujar a la posici\u00f3n de prueba y cerrar la puerta del armario. Utilice el balanc\u00edn para girar a la<strong>lugar de la prueba<\/strong>(interruptor de desconexi\u00f3n desconectado), presione la puerta de accionamiento de puesta a tierra; utilice el asa para<strong>Desconecte el interruptor de puesta a tierra.<\/strong>(indicador de confirmaci\u00f3n), contin\u00fae agitando hasta que<strong>Lugar de trabajo<\/strong>(como se muestra en las figuras 11-13).<\/p>\n<div id=\"attachment_15633\" style=\"width: 418px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15633\" class=\"wp-image-15633\" title=\"Figura 11-13 Operaci\u00f3n de inserci\u00f3n del disyuntor de alta tensi\u00f3n\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339.png\" alt=\"Figura 11-13 Operaci\u00f3n de inserci\u00f3n del disyuntor de alta tensi\u00f3n\" width=\"408\" height=\"171\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339.png 799w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339-300x126.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339-768x322.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339-18x8.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/60ed68dddcc27e216f47e5ad6232c339-600x252.png 600w\" sizes=\"auto, (max-width: 408px) 100vw, 408px\" \/><p id=\"caption-attachment-15633\" class=\"wp-caption-text\">Figura 11-13 Operaci\u00f3n de inserci\u00f3n del disyuntor de alta tensi\u00f3n<\/p><\/div>\n<p><strong>(6) Inspecci\u00f3n:<\/strong>Compruebe que los indicadores del cuadro de distribuci\u00f3n, el estado del interruptor de alta tensi\u00f3n y las indicaciones de posici\u00f3n coinciden con la condici\u00f3n de espera.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section style=\"margin-bottom: 40px;\">\n<h2 style=\"background: #1f365c; color: #fff; padding: 12px 25px; border-left: 10px solid #ef9308; border-radius: 4px; font-size: 20px;\">En segundo lugar, las precauciones de mantenimiento rutinario del cuadro de distribuci\u00f3n de alta tensi\u00f3n.<\/h2>\n<div style=\"background: #fff; border: 2px solid #1f365c; padding: 25px; border-radius: 8px; margin-top: 20px;\">\n<ul style=\"list-style-type: none; padding: 0;\">\n<li style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"><span style=\"background: #c0392b; color: #fff; padding: 2px 8px; border-radius: 3px; font-weight: bold; margin-right: 15px; font-size: 12px;\">proh\u00edben terminantemente<\/span><br \/>\n<strong>Los cuadros de alta tensi\u00f3n tienen estrictamente prohibido trabajar con electricidad<\/strong>Aseg\u00farese siempre de que el equipo no est\u00e1 bajo tensi\u00f3n antes de trabajar en \u00e9l.<\/li>\n<li style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"><span style=\"background: #1f365c; color: #fff; padding: 2px 8px; border-radius: 3px; font-weight: bold; margin-right: 15px; font-size: 12px;\">actas<\/span><br \/>\nTrabaje respetando estrictamente los requisitos de seguridad: Colocar en posici\u00f3n de prueba \u2192 desconectar el interruptor seccionador \u2192 descargar a tierra. Restablecer el orden inverso despu\u00e9s de la reparaci\u00f3n.<\/li>\n<li style=\"display: flex; align-items: flex-start;\"><span style=\"background: #ef9308; color: #fff; padding: 2px 8px; border-radius: 3px; font-weight: bold; margin-right: 15px; font-size: 12px;\">proteger<\/span>\n<p><strong>Debe tomar las debidas precauciones de seguridad y utilizar herramientas y equipos de protecci\u00f3n aislados de alta tensi\u00f3n.<\/strong>La persona debe ser asistida por una persona especializada.<strong>Est\u00e1 terminantemente prohibido que el personal se acerque a la placa de protecci\u00f3n superior del cuadro el\u00e9ctrico.<\/strong><\/li>\n<\/ul>\n<\/div>\n<\/section>\n<footer style=\"text-align: center; margin-top: 60px; padding-top: 30px; border-top: 1px solid #eee; color: #999; font-size: 13px;\">Kit de formaci\u00f3n para oficiales de electricidad y electr\u00f3nica del buque (ETO) | Pr\u00e1cticas de revisi\u00f3n del interruptor principal de alta tensi\u00f3n | Edici\u00f3n revisada de 2026<\/footer>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Procedimientos de revisi\u00f3n de interruptores principales de alta tensi\u00f3n \u26a0\ufe0f PELIGRO DE ALTA TENSI\u00d3N: Observe estrictamente los procedimientos operativos y los requisitos de enclavamiento I. Procedimientos operativos para la revisi\u00f3n de interruptores principales de alta tensi\u00f3n en buques...<\/p>","protected":false},"author":1,"featured_media":15634,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15631","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/comments?post=15631"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15631\/revisions"}],"predecessor-version":[{"id":15635,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio\/15631\/revisions\/15635"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media\/15634"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/media?parent=15631"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_category?post=15631"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/es\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}