{"id":15439,"date":"2026-01-05T23:16:22","date_gmt":"2026-01-05T15:16:22","guid":{"rendered":"http:\/\/www.erun-tech.com\/?post_type=dt_portfolio&#038;p=15439"},"modified":"2026-01-06T11:00:14","modified_gmt":"2026-01-06T03:00:14","slug":"zhongzaixunwenyuzhongyaofuzaizidongqiehuanchuanbodianzhandezhihuishouhu","status":"publish","type":"dt_portfolio","link":"http:\/\/www.erun-tech.com\/id\/project\/zhongzaixunwenyuzhongyaofuzaizidongqiehuanchuanbodianzhandezhihuishouhu","title":{"rendered":"Penyelidikan tugas berat dan pengalihan otomatis beban kritis: penjagaan cerdas pembangkit listrik kapal"},"content":{"rendered":"<h1 class=\"query-text-line ng-star-inserted\">Operasi pengalihan otomatis untuk permintaan beban berat dan beban kritis<\/h1>\n<p class=\"query-text-line ng-star-inserted\"><strong>I. Tinjauan umum tentang fungsi pertanyaan pemuatan ulang<\/strong><\/p>\n<p class=\"query-text-line ng-star-inserted\">\n<p class=\"query-text-line ng-star-inserted\">Pada kapal modern, beban daya besar dengan daya tunggal ratusan kilowatt atau bahkan ribuan kilowatt merupakan hal yang lumrah, seperti perangkat propulsi, perangkat propulsi samping, mesin pengapung besar, pompa pemadam kebakaran besar, dan beberapa beban daya untuk tujuan khusus pada kapal teknik, yang kapasitasnya bahkan dapat dibandingkan dengan kapasitas satu unit generator. Untuk memulai beban sebesar itu, perlu dilihat apakah cadangan daya yang ada di pembangkit listrik kapal dapat memenuhi persyaratan untuk memulai dan mengoperasikan beban besar. Jika tidak memungkinkan untuk memenuhi persyaratan start dan pengoperasian beban besar, unit siaga harus dihidupkan terlebih dahulu, dan cadangan daya harus dipastikan mencukupi sebelum mengizinkan beban besar dihubungkan ke jaringan listrik. Ini adalah fungsi penyelidikan beban berat.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Untuk tujuan fungsi interogasi beban berat, sinyal dari tombol \u201cstart\u201d pada kotak start beban daya tinggi tidak dikirim ke sirkuit kontrol di kotak kontrol, tetapi ke sistem manajemen pembangkit listrik otomatis, yang menentukan apakah perlu untuk memulai unit siaga atau tidak. Hanya jika ada cadangan daya yang cukup dalam jaringan, sistem manajemen mengirimkan perintah start untuk beban daya tinggi dan mengoperasikannya.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Rangkaian interogasi start ditunjukkan pada Gambar 2-9. Kontak \u201cstart diperbolehkan\u201d ditambahkan ke sirkuit start asli. Sepasang kontak ini dapat dipasok langsung oleh sistem kontrol otomatis atau dapat diperpanjang dengan relai. Mengingat sistem kontrol otomatis pada umumnya hanya mengeluarkan satu pasang kontak, sebuah relai ekstensi K\u2082 disediakan di starter. Tombol start S\u2082 memiliki dua pasang kontak yang biasanya terbuka, satu untuk memulai dan satu lagi untuk memulai pertanyaan. Ketika sakelar pemilih pertanyaan S\u2083 diatur pada posisi \u201cpertanyaan\u201d dan S\u2082 ditekan, garis start tidak akan diaktifkan karena koil K\u2082 tidak diaktifkan; ketika garis pertanyaan dinyalakan, pertanyaan awal akan dikirim ke sistem kontrol otomatis. Ketika diizinkan untuk memulai, kontak output yang sesuai dari sistem kontrol otomatis akan ditutup, koil K\u2082 akan diberi energi dan lampu indikator akan menyala, menunjukkan bahwa itu dapat dimulai, kemudian tekan tombol start S\u2082 lagi, koil K\u2081 akan diberi energi dan motor akan mulai berjalan. Pada saat yang sama, kontak bantu yang biasanya tertutup dari K\u2081 akan diaktifkan untuk memutus jalur pertanyaan, untuk menghindari pertanyaan lagi dalam kasus berjalan.<\/p>\n<p class=\"query-text-line ng-star-inserted\"><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15440\" title=\"ca71771206d76b22288952161b79f6a3\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3.png\" alt=\"ca71771206d76b22288952161b79f6a3\" width=\"860\" height=\"630\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3.png 860w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3-300x220.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3-768x563.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3-16x12.png 16w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/ca71771206d76b22288952161b79f6a3-600x440.png 600w\" sizes=\"auto, (max-width: 860px) 100vw, 860px\" \/>II. Demonstrasi fungsi kueri muat ulang<\/strong><\/p>\n<p class=\"query-text-line ng-star-inserted\">\n<p class=\"query-text-line ng-star-inserted\">Proses mendemonstrasikan kueri yang kelebihan beban pada simulator adalah sebagai berikut:<\/p>\n<p class=\"query-text-line ng-star-inserted\">(1) Pengaturan Status 1: Pembangkit listrik dalam kondisi otomatis, berjalan sendiri, mendekati beban 60%.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Tekan tombol pertanyaan beban berat dari beban analog, cadangan daya jaringan tidak mencukupi, lampu indikator kuning berkedip atas nama menunggu pembangkit listrik bergabung; amati penyalaan otomatis unit, penggabungan otomatis, dan transfer otomatis beban; kemudian lampu indikator kuning padam, beban secara otomatis dimasukkan ke dalam operasi, dan lampu indikator hijau menyala, dalam proses ini, amati dengan cermat proses perubahan beban jaringan pada saat input beban.<\/p>\n<p class=\"query-text-line ng-star-inserted\">(2) Pengaturan Status 2: Pembangkit listrik dalam keadaan otomatis, dengan dua mesin yang terhubung secara paralel, masing-masing membawa beban kurang dari 50%.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Tekan tombol interogasi tugas berat dari beban analog, daya cadangan jaringan cukup untuk memulai beban secara langsung dan lampu indikator hijau menyala.<\/p>\n<p class=\"query-text-line ng-star-inserted\">\n<p class=\"query-text-line ng-star-inserted\"><strong>iii. pengalihan otomatis beban berat<\/strong><\/p>\n<p class=\"query-text-line ng-star-inserted\">\n<p class=\"query-text-line ng-star-inserted\">Sistem yang sangat penting di atas kapal, seperti sistem pelumasan mesin utama dan sistem air laut utama, harus dipastikan berjalan tanpa gangguan dalam kondisi kerja yang sesuai. Selain dua set peralatan listrik, peralatan listrik dari sistem ini juga harus dilengkapi dengan fungsi peralihan otomatis, sehingga ketika peralatan operasi gagal, satu set peralatan lain dapat secara otomatis dioperasikan untuk memenuhi kebutuhan operasi kapal. Sekarang ambil peralihan otomatis pompa oli mesin utama sebagai contoh.<\/p>\n<p class=\"query-text-line ng-star-inserted\">1 . Komposisi Sistem dan Alur Kerja<\/p>\n<p class=\"query-text-line ng-star-inserted\">Sistem peralihan otomatis pompa oli geser mesin utama kapal terutama terdiri dari dua bagian utama: pompa oli geser dan komponen kontrol, seperti yang ditunjukkan pada Gambar 2-10. Diantaranya, sakelar tekanan perlu dipasang di pipa pompa, dan komponen kontrol mencakup sirkuit listrik kontrol tujuan umum PLC.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Diagram sirkuit kontrol pengalihan otomatis pompa oli utama ditunjukkan pada Gambar 2-11. Alur kerjanya adalah: mulai secara manual pompa pelumasan No. 1, pompa pelumasan No. 2 untuk memilih status otomatis. 1 pompa pelumasan untuk pompa utama, pompa pelumasan No. 2 untuk pompa siaga, hanya setelah pompa utama bekerja, pompa siaga dapat berada dalam keadaan siaga (saat ini, pompa siaga untuk memilih status otomatis).<\/p>\n<p class=\"query-text-line ng-star-inserted\">Fungsi 1: Setelah pompa utama dihidupkan, pompa siaga memilih kondisi otomatis, dan ketika PLC mendeteksi sinyal berjalan dari pompa utama, pompa siaga menunjukkan output \u201csiaga\u201d. Ketika sinyal tekanan rendah dari sakelar tekanan berlangsung selama 10 detik, pompa siaga dihidupkan dan pompa utama dihentikan (pompa utama melaporkan kesalahan).<\/p>\n<p class=\"query-text-line ng-star-inserted\">Fungsi 2: Ketika pompa sedang berjalan dan busbar switchboard dinonaktifkan, penyalaan berikutnya akan mengembalikan pompa ke kondisi sebelum dinonaktifkan dalam waktu 20 detik (fungsi ini tidak terpengaruh oleh sakelar tekanan atau mode otomatis).<\/p>\n<p class=\"query-text-line ng-star-inserted\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15441\" title=\"592adb399743ad5d60e51c26f9495069\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069.png\" alt=\"592adb399743ad5d60e51c26f9495069\" width=\"1426\" height=\"554\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069.png 1426w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069-300x117.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069-1024x398.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069-768x298.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069-18x7.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/592adb399743ad5d60e51c26f9495069-600x233.png 600w\" sizes=\"auto, (max-width: 1426px) 100vw, 1426px\" \/><\/p>\n<p class=\"query-text-line ng-star-inserted\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15442\" title=\"f92365db2afd8ba437fff46a3868b155\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155.png\" alt=\"f92365db2afd8ba437fff46a3868b155\" width=\"1392\" height=\"824\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155.png 1392w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155-300x178.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155-1024x606.png 1024w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155-768x455.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155-18x12.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/f92365db2afd8ba437fff46a3868b155-600x355.png 600w\" sizes=\"auto, (max-width: 1392px) 100vw, 1392px\" \/>2. Prinsip dan penyesuaian sakelar tekanan<\/p>\n<p class=\"query-text-line ng-star-inserted\">Peralihan otomatis pompa oli utama biasanya dilakukan dengan menggunakan sakelar tekanan sebagai sinyal pemicu.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Berikut ini adalah contoh regulator tekanan Model YT-1226. Gambar 2-12 menunjukkan struktur regulator tekanan Model YT-1226. Sinyal input terukur, tekanan P, dihubungkan ke ruang pengukuran, diubah menjadi sinyal gaya oleh bellow, dan digunakan sebagai tuas pembanding untuk menghasilkan torsi terukur. Selain itu, tuas digerakkan dengan torsi tertentu yang dihasilkan oleh pegas nilai tertentu dan torsi diferensial yang dihasilkan oleh pegas amplitudo diferensial.<\/p>\n<p class=\"query-text-line ng-star-inserted\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15443\" title=\"db4ec3fc68b5b119b1bc3ab185b582cb\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb.png\" alt=\"db4ec3fc68b5b119b1bc3ab185b582cb\" width=\"884\" height=\"870\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb.png 884w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb-300x295.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb-768x756.png 768w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb-12x12.png 12w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/db4ec3fc68b5b119b1bc3ab185b582cb-600x590.png 600w\" sizes=\"auto, (max-width: 884px) 100vw, 884px\" \/>Apabila tekanan input P berada pada batas tekanan yang lebih rendah, tuas pembanding berada pada posisi horizontal. Pada titik ini, kontak bergerak meninggalkan kontak statis 1 dan menutup kontak statis 2. Pada titik ini, terdapat celah antara sekrup aksi dan cakram pegas amplitudo, dan pegas amplitudo tidak bekerja pada tuas. Saat tekanan P meningkat, tuas komparatif berputar berlawanan arah jarum jam di sekitar titik pivot, menggerakkan tepi bawah pegas daun ke kiri oleh lengan pivot, dan mengompresi pegas oleh daun, menyimpan energi elastis. Pada saat yang sama, celah antara sekrup aksi dan cakram pegas amplitudo berangsur-angsur menghilang, dan saat tuas pembanding terus berputar, tidak hanya harus mengatasi torsi yang diberikan, tetapi juga torsi amplitudo. Ketika tuas pembanding berputar melalui sudut tertentu, yaitu ketika tekanan terukur P mencapai nilai batas atas, lidah buluh berada tepat pada bidang yang sama dengan buluh, pegas memiliki kesempatan untuk melepaskan energi, dan dengan cepat meletuskan buluh, sehingga kontak yang dapat digerakkan meninggalkan kontak statis 2 dan ditutup dengan kontak statis 1. Ketika tekanan P berkurang, tuas pembanding berputar searah jarum jam di sekitar titik pivot, dan ketika tuas pembanding kembali ke posisi horizontal, buluh lidah berada pada bidang yang sama dengan buluh, dan pegas yang tersandung membuka buluh lidah sekali lagi dan menutup kontak yang dapat digerakkan dengan kontak statis 2 menjauh dari kontak statis 1. Ketika tekanan P bervariasi antara nilai batas atas dan bawah, pegas tetap tidak berubah, yaitu output regulator tetap tidak berubah.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Nilai batas bawah sakelar tekanan disesuaikan oleh pegas dengan nilai yang diberikan, dilambangkan dengan P\u2081. Kenop penyesuaian perbedaan amplitudo digunakan untuk menyesuaikan perbedaan amplitudo \u0394P. Nilai batas atas sakelar tekanan, Pa, sama dengan nilai batas bawah, P\u2081, ditambah dengan perbedaan amplitudo, \u0394P, yaitu, Pa = P\u2081 + \u0394P. Oleh karena itu, nilai batas atas sakelar tekanan ditetapkan dengan menyesuaikan perbedaan amplitudo.<\/p>\n<p class=\"query-text-line ng-star-inserted\">Rentang indikasi sakelar tekanan YT-1226 adalah P\u2081 = 0 ~ 0,2 MPa, dan kenop penyesuaian perbedaan amplitudo ditandai dengan blok kelulusan 10, yang sesuai dengan rentang perbedaan amplitudo \u25b3 P = 0,07 ~ 0,25 MPa. Jumlah nilai X yang akan disesuaikan dengan kenop penyesuaian perbedaan amplitudo dapat diperkirakan menurut rumus berikut. Namun demikian, karena akurasi timbangan yang rendah, maka, timbangan ini harus diuji atau disesuaikan di lokasi selama penggunaan aktual.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15444\" title=\"7dbbfd082c8380f0597b1dba27ddcbf8\" src=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7dbbfd082c8380f0597b1dba27ddcbf8.png\" alt=\"7dbbfd082c8380f0597b1dba27ddcbf8\" width=\"724\" height=\"120\" srcset=\"http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7dbbfd082c8380f0597b1dba27ddcbf8.png 724w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7dbbfd082c8380f0597b1dba27ddcbf8-300x50.png 300w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7dbbfd082c8380f0597b1dba27ddcbf8-18x3.png 18w, http:\/\/www.erun-tech.com\/wp-content\/uploads\/2026\/01\/7dbbfd082c8380f0597b1dba27ddcbf8-600x99.png 600w\" sizes=\"auto, (max-width: 724px) 100vw, 724px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Penyelidikan beban berat dan operasi pengalihan otomatis beban penting I. Gambaran umum fungsi penyelidikan beban berat Pada kapal modern, daya satu mesin hingga ratusan kilowatt atau bahkan kilowatt beban berdaya tinggi ...<\/p>","protected":false},"author":1,"featured_media":15445,"comment_status":"open","ping_status":"closed","template":"","dt_portfolio_category":[891],"dt_portfolio_tags":[],"class_list":["post-15439","dt_portfolio","type-dt_portfolio","status-publish","has-post-thumbnail","hentry","dt_portfolio_category-dianzidianqiyuanshicaopinggukecheng","dt_portfolio_category-891","description-off"],"_links":{"self":[{"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio\/15439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio"}],"about":[{"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/types\/dt_portfolio"}],"author":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/comments?post=15439"}],"version-history":[{"count":1,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio\/15439\/revisions"}],"predecessor-version":[{"id":15446,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio\/15439\/revisions\/15446"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/media\/15445"}],"wp:attachment":[{"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/media?parent=15439"}],"wp:term":[{"taxonomy":"dt_portfolio_category","embeddable":true,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio_category?post=15439"},{"taxonomy":"dt_portfolio_tags","embeddable":true,"href":"http:\/\/www.erun-tech.com\/id\/wp-json\/wp\/v2\/dt_portfolio_tags?post=15439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}